{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T06:32:33Z","timestamp":1791873153815,"version":"4.3.4"},"reference-count":25,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:sec><jats:title>Background\/aims<\/jats:title><jats:p>To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean value of IOP measured by GAT was 13.97\u00b12.80\u2009mm Hg, which was not significantly different from that by RT without LM (13.75\u00b12.44\u2009mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21\u00b12.91\u2009mm Hg; P&lt;0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: \u22121.5) and RT without LM (mean: \u22121.2). Among the high IOPs (&gt;20\u2009mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P&lt;0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P&lt;0.001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.<\/jats:p><\/jats:sec>","DOI":"10.1136\/bjophthalmol-2017-311587","type":"journal-article","created":{"date-parts":[[2018,2,2]],"date-time":"2018-02-02T17:20:18Z","timestamp":1517592018000},"page":"1515-1519","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry"],"prefix":"10.1136","volume":"102","author":[{"given":"Sung Uk","family":"Baek","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahnul","family":"Ha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6037-8449","authenticated-orcid":false,"given":"Young Kook","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Wook","family":"Jeoung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki Ho","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,2,2]]},"reference":[{"key":"2020050713002806000_102.11.1515.1","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S0161-6420(96)30741-0","article-title":"Standardizing the measurement of intraocular pressure for clinical research. Guidelines from the eye care technology forum","volume":"103","author":"Kass","year":"1996","journal-title":"Ophthalmology"},{"key":"2020050713002806000_102.11.1515.2","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1159\/000310527","article-title":"Influence of topical anesthesia on tonometric values of intraocular pressure","volume":"208","author":"Baudouin","year":"1994","journal-title":"Ophthalmologica"},{"key":"2020050713002806000_102.11.1515.3","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1038\/sj.eye.6702669","article-title":"Comparison of the ICare rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists","volume":"22","author":"Abraham","year":"2008","journal-title":"Eye"},{"key":"2020050713002806000_102.11.1515.4","doi-asserted-by":"publisher","DOI":"10.3310\/hta16150"},{"key":"2020050713002806000_102.11.1515.5","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.089870"},{"key":"2020050713002806000_102.11.1515.6","doi-asserted-by":"publisher","DOI":"10.1111\/aos.12109"},{"key":"2020050713002806000_102.11.1515.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.02.035"},{"key":"2020050713002806000_102.11.1515.8","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1097\/IJG.0b013e318237caa2","article-title":"Comparison of intraocular pressure measurements and assessment of intraobserver and interobserver reproducibility with the portable ICare rebound tonometer and Goldmann applanation tonometer in glaucoma patients","volume":"22","author":"Salim","year":"2013","journal-title":"J Glaucoma"},{"key":"2020050713002806000_102.11.1515.9","doi-asserted-by":"publisher","DOI":"10.1016\/0039-6257(93)90053-A"},{"key":"2020050713002806000_102.11.1515.10","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00802-3"},{"key":"2020050713002806000_102.11.1515.11","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-007-0758-3"},{"key":"2020050713002806000_102.11.1515.12","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/IJG.0b013e31816f760c","article-title":"Comparison of rebound tonometer and Goldmann handheld applanation tonometer in congenital glaucoma","volume":"18","author":"Martinez-de-la-Casa","year":"2009","journal-title":"J Glaucoma"},{"key":"2020050713002806000_102.11.1515.13","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1111\/j.1365-2133.2006.07495.x","article-title":"Ethnic characteristics of eyelashes: a comparative analysis in Asian and Caucasian females","volume":"155","author":"Na","year":"2006","journal-title":"Br J Dermatol"},{"key":"2020050713002806000_102.11.1515.14","doi-asserted-by":"publisher","DOI":"10.1097\/01.prs.0000304608.33432.67"},{"key":"2020050713002806000_102.11.1515.15","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1007\/s10384-014-0343-3","article-title":"Effectiveness of the ICare rebound tonometer in patients with overestimated intraocular pressure due to tight orbit syndrome","volume":"58","author":"Lee","year":"2014","journal-title":"Jpn J Ophthalmol"},{"key":"2020050713002806000_102.11.1515.16","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1111\/j.1755-3768.2009.01755.x","article-title":"Tight orbit syndrome: a previously unrecognized cause of open-angle glaucoma","volume":"88","author":"Lee","year":"2010","journal-title":"Acta Ophthalmol"},{"key":"2020050713002806000_102.11.1515.17","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)01793-2"},{"key":"2020050713002806000_102.11.1515.18","doi-asserted-by":"publisher","DOI":"10.2460\/javma.238.10.1292"},{"key":"2020050713002806000_102.11.1515.19","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)01513-1"},{"key":"2020050713002806000_102.11.1515.20","first-page":"732","article-title":"Effect of resisting tonometry on intraocular pressure","volume":"65","author":"Frantz","year":"1994","journal-title":"J Am Optom Assoc"},{"key":"2020050713002806000_102.11.1515.21","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1969.00990020633011"},{"key":"2020050713002806000_102.11.1515.22","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/0002-9394(83)90459-2","article-title":"Goldmann applanation tonometry in patients with regular corneal astigmatism","volume":"96","author":"Holladay","year":"1983","journal-title":"Am J Ophthalmol"},{"key":"2020050713002806000_102.11.1515.23","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1111\/j.1444-0938.2003.tb03068.x","article-title":"The relationship between central corneal thickness and Goldmann applanation tonometry","volume":"86","author":"Lle\u00f3","year":"2003","journal-title":"Clin Exp Optom"},{"key":"2020050713002806000_102.11.1515.24","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1097\/IJG.0000000000000133","article-title":"Corneal deformation parameters provided by the Corvis-ST Pachy-Tonometer in healthy subjects and glaucoma patients","volume":"24","author":"Salvetat","year":"2015","journal-title":"J Glaucoma"},{"key":"2020050713002806000_102.11.1515.25","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e31815d784c"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2017-311587","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T08:56:52Z","timestamp":1601110612000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2017-311587"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,2]]},"references-count":25,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2018,10,22]]},"published-print":{"date-parts":[[2018,11]]}},"alternative-id":["10.1136\/bjophthalmol-2017-311587"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311587","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2,2]]}}}