{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T22:42:38Z","timestamp":1785278558861,"version":"3.55.0"},"reference-count":18,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:sec><jats:title>Aims<\/jats:title><jats:p>To examine corneal biomechanics in healthy and keratoconic eyes, with or without crosslinking obtained by ultrahigh-speed Scheimpflug measurements (Corvis ST).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>One hundred and seventeen\u00a0eyes were studied in three groups: group 1 (n=39) contained keratoconic eyes without crosslinking. Group 2 (CXL; n=28) comprised keratoconic eyes after crosslinking. These were compared with a control group (n=50 matched healthy eyes). In addition, 10 keratoconus patients, before and after CXL treatment, respectively, were examined.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The novel parameter A1L\u2013A2L demonstrated highly significant differences between crosslinked corneas and untreated keratoconic or healthy corneas. Velocity during second applanation (A2V) and deformation amplitude (DA) were significantly increased in crosslinked keratoconic eyes both compared with untreated keratoconic eyes and with healthy controls. Radius at highest curvature\u00a0also was significant among all groups. Inward applanation length (A1L) was significantly increased in controls, whereas outward applanation length (A2L) was significantly reduced in crosslinked keratoconic eyes compared with both other groups. The follow-up analysis revealed statistically significant changes in pachymetry and intraocular pressure and showed tendencies towards significance in applanation times 1 and 2 and in DA.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Both A2V and A2L are viable parameters to discriminate healthy from keratoconic but also crosslinked from non-crosslinked keratoconic corneas. The difference of A1L\u2212A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Follow-up examination in a small cohort allows distinction between crosslinked and untreated keratoconus in follow-up examinations. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Measurements of corneal deformation using dynamic ultrahigh-speed Scheimpflug technology are reproducible and provide useful information about keratoconus assessment and biomechanics. Therefore, the Corvis ST seems to provide useful technology to monitor therapeutic success of crosslinking treatment.<\/jats:p><\/jats:sec>","DOI":"10.1136\/bjophthalmol-2017-311627","type":"journal-article","created":{"date-parts":[[2018,6,5]],"date-time":"2018-06-05T16:16:11Z","timestamp":1528215371000},"page":"558-564","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":22,"title":["Biomechanical assessment of healthy and keratoconic corneas (with\/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L\u2212A2L)"],"prefix":"10.1136","volume":"103","author":[{"given":"Thomas A","family":"Fuchsluger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susanne","family":"Brettl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd","family":"Geerling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Kaisers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Franko Zeitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,6,5]]},"reference":[{"key":"2023050800351115000_103.4.558.1","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"2023050800351115000_103.4.558.2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.140012"},{"key":"2023050800351115000_103.4.558.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"2023050800351115000_103.4.558.4","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318279eb87"},{"key":"2023050800351115000_103.4.558.5","doi-asserted-by":"crossref","first-page":"558","DOI":"10.3928\/1081597X-20130719-06","article-title":"Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas","volume":"29","author":"Nemeth","year":"2013","journal-title":"J Refract Surg"},{"key":"2023050800351115000_103.4.558.6","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13172"},{"key":"2023050800351115000_103.4.558.7","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","article-title":"Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes","volume":"157","author":"Huseynova","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"2023050800351115000_103.4.558.8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/147516","article-title":"Corneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J Ophthalmol"},{"key":"2023050800351115000_103.4.558.9","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13715"},{"key":"2023050800351115000_103.4.558.10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/748671","article-title":"Evaluation of corneal deformation analyzed with Scheimpflug based device in healthy eyes and diseased ones","volume":"2014","author":"Lanza","year":"2014","journal-title":"Biomed Res Int"},{"key":"2023050800351115000_103.4.558.11","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140513-02"},{"key":"2023050800351115000_103.4.558.12","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)02220-1"},{"key":"2023050800351115000_103.4.558.13","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11563"},{"key":"2023050800351115000_103.4.558.14","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-303400"},{"key":"2023050800351115000_103.4.558.15","doi-asserted-by":"crossref","first-page":"785","DOI":"10.3928\/1081597X-20140930-01","article-title":"Assessment of ocular biomechanics using dynamic ultra high-speed Scheimpflug imaging in keratoconic and normal eyes","volume":"30","author":"Tian","year":"2014","journal-title":"J Refract Surg"},{"key":"2023050800351115000_103.4.558.16","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.1097\/ICO.0000000000000598","article-title":"Screening for keratoconus with new dynamic biomechanical in vivo scheimpflug analyses","volume":"34","author":"Steinberg","year":"2015","journal-title":"Cornea"},{"key":"2023050800351115000_103.4.558.17","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12509"},{"key":"2023050800351115000_103.4.558.18","unstructured":"Ambr\u00f3sio R , Caldas DL , Ramos IC , et al . Corneal biomechanical assessment using dynamic ultrahigh-speed Scheimpflug technology noncontact tonometry (UHS-ST NCT): preliminary results; p8-p 9. Presented at ASCRS ASOA, San Diego, Calif., USA, March 25-29, 2011. 2011. http:\/\/ascrs2011.abstractsnet.com\/acover.wcs?entryid=000209 (accessed 27 Apr 2018)."}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2017-311627","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,8]],"date-time":"2023-05-08T07:37:26Z","timestamp":1683531446000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2017-311627"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,5]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,3,22]]},"published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1136\/bjophthalmol-2017-311627"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311627","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,5]]}}}