{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T12:30:35Z","timestamp":1791549035057,"version":"4.3.4"},"reference-count":25,"publisher":"BMJ","issue":"2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"accepted":{"date-parts":[[2018,3,29]]},"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>To evaluate rotation and its influencing factors of an aspheric one-piece hydrophobic acrylic intraocular lens (IOL) Vivinex XY1 during 6 months after operation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this institutional trial, 122 eyes of 66 patients were implanted with a non-toric aspheric IOL Vivinex XY1 (Hoya\u00a0Corporation, Tokyo, Japan). IOL alignment was assessed at the end of surgery, 1\u2009hour, 1\u2009week, 1\u2009month and 6 months after implantation. Confounding factors such as axial length, presence of anterior fibrosis and randomised implantation in four different intended axes (0\u00b0,\u00a045\u00b0,\u00a090\u00b0,\u00a0135\u00b0) were evaluated. Decentration and tilt were measured using a Purkinje metre.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Assessment of rotational stability was possible for 103 of 122 implanted IOLs 6 months after eye surgery. The median absolute rotation was 1.1\u00b0\u00a0(range:\u00a00\u00b0\u20135\u00b0). Rotation was significantly increased within the first hour after operation compared with later time-points (p&lt;0.001). No correlation was found with axial length and rotation (Spearman\u2019s r=0.048, p=0.63). No significant difference was observed regarding different implantation axes (p=0.75). Rotation was not influenced by the presence of anterior fibrosis (p=0.98).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Assessing the true IOL position at the end of surgery is crucial for the evaluation of rotational stability of IOLs. No IOL rotation exceeding 5\u00b0 could be detected 6 months after surgery.<\/jats:p><\/jats:sec>","DOI":"10.1136\/bjophthalmol-2017-311797","type":"journal-article","created":{"date-parts":[[2018,4,19]],"date-time":"2018-04-19T15:15:21Z","timestamp":1524150921000},"page":"186-190","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":46,"title":["True rotational stability of a single-piece hydrophobic intraocular lens"],"prefix":"10.1136","volume":"103","author":[{"given":"Daniel","family":"Schartm\u00fcller","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabine","family":"Schriefl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Schwarzenbacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Leydolt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rupert","family":"Menapace","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,4,17]]},"reference":[{"key":"2024100707200662000_103.2.186.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.02.025"},{"key":"2024100707200662000_103.2.186.2","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1001\/jamaophthalmol.2014.3602","article-title":"Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial","volume":"132","author":"Visser","year":"2014","journal-title":"JAMA Ophthalmol"},{"key":"2024100707200662000_103.2.186.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80232-5"},{"key":"2024100707200662000_103.2.186.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.07.019"},{"key":"2024100707200662000_103.2.186.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.09.032"},{"key":"2024100707200662000_103.2.186.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.05.018"},{"key":"2024100707200662000_103.2.186.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.08.028"},{"key":"2024100707200662000_103.2.186.8","doi-asserted-by":"crossref","first-page":"321","DOI":"10.5301\/ejo.5000696","article-title":"Rotational stability and patient satisfaction after implantation of a new toric IOL","volume":"26","author":"Gy\u00f6ngy\u00f6ssy","year":"2016","journal-title":"Eur J Ophthalmol"},{"key":"2024100707200662000_103.2.186.9","doi-asserted-by":"crossref","DOI":"10.1186\/1471-2415-8-8","article-title":"Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study","volume":"8","author":"Zuberbuhler","year":"2008","journal-title":"BMC Ophthalmol"},{"key":"2024100707200662000_103.2.186.10","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.163485"},{"key":"2024100707200662000_103.2.186.11","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306656"},{"key":"2024100707200662000_103.2.186.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.04.043"},{"key":"2024100707200662000_103.2.186.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.04.022"},{"key":"2024100707200662000_103.2.186.14","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1159\/000353389","article-title":"Visual and refractive outcomes after cataract surgery with implantation of a new toric intraocular lens","volume":"4","author":"Mazzini","year":"2013","journal-title":"Case Rep Ophthalmol"},{"key":"2024100707200662000_103.2.186.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.05.031"},{"key":"2024100707200662000_103.2.186.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.11.033"},{"key":"2024100707200662000_103.2.186.17","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.ajo.2008.05.040","article-title":"Long-term Staar toric intraocular lens rotational stability","volume":"146","author":"Jampaulo","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"2024100707200662000_103.2.186.18","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1016\/j.jcrs.2013.06.006","article-title":"Accuracy and precision of a new system for measuring toric intraocular lens axis rotation","volume":"39","author":"Sanders","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"2024100707200662000_103.2.186.19","doi-asserted-by":"crossref","first-page":"358","DOI":"10.3928\/1081597X-20150521-01","article-title":"Microincision hydrophobic acrylic aspheric toric intraocular lens for astigmatism and cataract correction","volume":"31","author":"Bissen-Miyajima","year":"2015","journal-title":"J Refract Surg"},{"key":"2024100707200662000_103.2.186.20","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1159\/000368658","article-title":"Influence of the overall intraocular lens diameter on rotational stability","volume":"53","author":"Harrer","year":"2015","journal-title":"Ophthalmic Res"},{"key":"2024100707200662000_103.2.186.21","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1016\/j.jcrs.2009.05.024","article-title":"Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens","volume":"35","author":"Saldanha","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"2024100707200662000_103.2.186.22","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90504-3"},{"key":"2024100707200662000_103.2.186.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.02.025"},{"key":"2024100707200662000_103.2.186.24","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-1022"},{"key":"2024100707200662000_103.2.186.25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.10.027"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2017-311797","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T14:21:41Z","timestamp":1728310901000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2017-311797"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,17]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2019,1,22]]},"published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.1136\/bjophthalmol-2017-311797"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311797","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,17]]}}}