{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T02:08:09Z","timestamp":1791857289636,"version":"4.3.4"},"reference-count":80,"publisher":"BMJ","issue":"12","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Br J Ophthalmol"],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:p>The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision.<\/jats:p>","DOI":"10.1136\/bjophthalmol-2018-312333","type":"journal-article","created":{"date-parts":[[2018,6,15]],"date-time":"2018-06-15T11:35:11Z","timestamp":1529062511000},"page":"1615-1620","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":89,"title":["Effects of tear film dynamics on quality of vision"],"prefix":"10.1136","volume":"102","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5402-3051","authenticated-orcid":false,"given":"Shizuka","family":"Koh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cynthia I","family":"Tung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasushi","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Jhanji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,6,15]]},"reference":[{"key":"2020050713002000000_102.12.1615.1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.76.3.157"},{"key":"2020050713002000000_102.12.1615.2","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.jtos.2017.05.008","article-title":"TFOS DEWS II definition and classification report","volume":"15","author":"Craig","year":"2017","journal-title":"Ocul Surf"},{"key":"2020050713002000000_102.12.1615.3","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.118.5.615"},{"key":"2020050713002000000_102.12.1615.4","doi-asserted-by":"crossref","unstructured":"Abetz L , Rajagopalan K , Mertzanis P , et al . Development and validation of the impact of dry eye on everyday life (IDEEL) questionnaire, a patient-reported outcomes (PRO) measure for the assessment of the burden of dry eye on patients. Health Qual Life Outcomes 2011;9:111.doi:10.1186\/1477-7525-9-111","DOI":"10.1186\/1477-7525-9-111"},{"key":"2020050713002000000_102.12.1615.5","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1001\/jamaophthalmol.2013.4503","article-title":"Development and validation of the dry eye-related quality-of-life score questionnaire","volume":"131","author":"Sakane","year":"2013","journal-title":"JAMA Ophthalmol"},{"key":"2020050713002000000_102.12.1615.6","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13818"},{"key":"2020050713002000000_102.12.1615.7","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.7.1050"},{"key":"2020050713002000000_102.12.1615.8","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(01)01365-4"},{"key":"2020050713002000000_102.12.1615.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.08.075"},{"key":"2020050713002000000_102.12.1615.10","doi-asserted-by":"crossref","first-page":"S83","DOI":"10.1097\/ICO.0000000000000998","article-title":"Mechanisms of visual disturbance in dry dye","volume":"35","author":"Koh","year":"2016","journal-title":"Cornea"},{"key":"2020050713002000000_102.12.1615.11","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/ICL.0000000000000232","article-title":"Overview of objective methods for assessing dynamic changes in optical quality","volume":"42","author":"Koh","year":"2016","journal-title":"Eye Contact Lens"},{"key":"2020050713002000000_102.12.1615.12","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.11.001949"},{"key":"2020050713002000000_102.12.1615.13","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200108000-00009"},{"key":"2020050713002000000_102.12.1615.14","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.jtos.2017.03.006","article-title":"TFOS DEWS II tear film report","volume":"15","author":"Willcox","year":"2017","journal-title":"Ocul Surf"},{"key":"2020050713002000000_102.12.1615.15","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(95)31024-X"},{"key":"2020050713002000000_102.12.1615.16","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.jtos.2016.09.003","article-title":". New perspectives on dry eye definition and diagnosis: a consensus report by the Asia dry eye society","volume":"15","author":"Tsubota","year":"2017","journal-title":"Ocul Surf"},{"key":"2020050713002000000_102.12.1615.17","unstructured":"Bohm KJ , Djalilian AR , Pflugfelder SC . Dry eye. In: Mannis MJ , Holland EJ , eds. Cornea. 4th edn. Philadelphia, USA: Elsevier, 2016:377\u201395."},{"key":"2020050713002000000_102.12.1615.18","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199912000-00016"},{"key":"2020050713002000000_102.12.1615.19","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)01430-7"},{"key":"2020050713002000000_102.12.1615.20","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1007\/978-1-4615-0717-8_160","article-title":"Predicting optical effects of tear film break up on retinal image quality using the shack-hartmann aberrometer and computational optical modeling","volume":"506","author":"Himebaugh","year":"2002","journal-title":"Adv Exp Med Biol"},{"key":"2020050713002000000_102.12.1615.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.027"},{"key":"2020050713002000000_102.12.1615.22","doi-asserted-by":"crossref","first-page":"243","DOI":"10.3928\/1081-597X-20040501-08","article-title":"Wavefront analysis of higher order aberrations in dry eye patients","volume":"20","author":"Mont\u00e9s-Mic\u00f3","year":"2004","journal-title":"J Refract Surg"},{"key":"2020050713002000000_102.12.1615.23","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0839"},{"key":"2020050713002000000_102.12.1615.24","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0017"},{"key":"2020050713002000000_102.12.1615.25","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0018"},{"key":"2020050713002000000_102.12.1615.26","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-005-0289-6"},{"key":"2020050713002000000_102.12.1615.27","doi-asserted-by":"publisher","DOI":"10.1364\/OE.14.012552"},{"key":"2020050713002000000_102.12.1615.28","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-007-0440-7"},{"key":"2020050713002000000_102.12.1615.29","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31815be9c8"},{"key":"2020050713002000000_102.12.1615.30","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-0762"},{"key":"2020050713002000000_102.12.1615.31","doi-asserted-by":"crossref","first-page":"59","DOI":"10.3928\/1081597X-20090101-08","article-title":"Variability of higher order wavefront aberrations after blinks","volume":"25","author":"Hagy\u00f3","year":"2009","journal-title":"J Refract Surg"},{"key":"2020050713002000000_102.12.1615.32","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8412"},{"key":"2020050713002000000_102.12.1615.33","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31826cfae5"},{"key":"2020050713002000000_102.12.1615.34","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.03.004"},{"key":"2020050713002000000_102.12.1615.35","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.ajo.2013.02.019","article-title":"The impact of dry eye disease on visual performance while driving","volume":"156","author":"Deschamps","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"2020050713002000000_102.12.1615.36","doi-asserted-by":"publisher","DOI":"10.1016\/S1542-0124(12)70081-2"},{"key":"2020050713002000000_102.12.1615.37","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4430"},{"key":"2020050713002000000_102.12.1615.38","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000195569.36185.fd"},{"key":"2020050713002000000_102.12.1615.39","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000237546.88464.6d"},{"key":"2020050713002000000_102.12.1615.40","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318194e962"},{"key":"2020050713002000000_102.12.1615.41","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11299"},{"key":"2020050713002000000_102.12.1615.42","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.ajo.2017.05.022","article-title":"Classification of fluorescein breakup patterns: a novel method of differential diagnosis for dry eye","volume":"180","author":"Yokoi","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"2020050713002000000_102.12.1615.43","first-page":"274","article-title":"Tear break-up time: clinical procedures and their effects","volume":"19","author":"Papas","year":"1999","journal-title":"Ophthalmic Physiol Opt"},{"key":"2020050713002000000_102.12.1615.44","doi-asserted-by":"crossref","first-page":"e257","DOI":"10.1097\/OPX.0000000000000648","article-title":"Agreement between automated and traditional measures of tear film breakup","volume":"92","author":"Cox","year":"2015","journal-title":"Optom Vis Sci"},{"key":"2020050713002000000_102.12.1615.45","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00245-8"},{"key":"2020050713002000000_102.12.1615.46","doi-asserted-by":"crossref","first-page":"2647","DOI":"10.1167\/iovs.17-21894","article-title":"The effect of ocular surface regularity on contrast sensitivity and straylight in dry eye","volume":"58","author":"Koh","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2020050713002000000_102.12.1615.47","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-11878"},{"key":"2020050713002000000_102.12.1615.48","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.jtos.2017.09.007","article-title":"Mechanisms, imaging and structure of tear film breakup","volume":"16","author":"King-Smith","year":"2018","journal-title":"Ocul Surf"},{"key":"2020050713002000000_102.12.1615.49","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2014.11.001"},{"key":"2020050713002000000_102.12.1615.50","doi-asserted-by":"crossref","unstructured":"Szczesna DH , Iskander DR . Robust estimation of tear film surface quality in lateral shearing interferometry. J Biomed Opt 2009;14:064039.doi:10.1117\/1.3275474","DOI":"10.1117\/1.3275474"},{"key":"2020050713002000000_102.12.1615.51","doi-asserted-by":"crossref","unstructured":"Szczesna DH , Alonso-Caneiro D , Iskander DR , et al . Lateral shearing interferometry, dynamic wavefront sensing, and high-speed videokeratoscopy for noninvasive assessment of tear film surface characteristics: a comparative study. J Biomed Opt 2010;15:037005.doi:10.1117\/1.3431103","DOI":"10.1117\/1.3431103"},{"key":"2020050713002000000_102.12.1615.52","first-page":"1783","article-title":"High-speed videotopographic measurement of tear film build-up time","volume":"43","author":"N\u00e9meth","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2020050713002000000_102.12.1615.53","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181b599bf"},{"key":"2020050713002000000_102.12.1615.54","doi-asserted-by":"crossref","first-page":"e671","DOI":"10.1111\/aos.12443","article-title":"Effect of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye","volume":"92","author":"Koh","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"2020050713002000000_102.12.1615.55","doi-asserted-by":"publisher","DOI":"10.1089\/jop.2012.0246"},{"key":"2020050713002000000_102.12.1615.56","doi-asserted-by":"crossref","first-page":"87","DOI":"10.2147\/OPTH.S122542","article-title":"Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery","volume":"11","author":"Inoue","year":"2017","journal-title":"Clin Ophthalmol"},{"key":"2020050713002000000_102.12.1615.57","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1097\/ICO.0b013e318294f97e","article-title":"Effect of rebamipide ophthalmic suspension on optical quality in the short break-up time type of dry eye","volume":"32","author":"Koh","year":"2013","journal-title":"Cornea"},{"key":"2020050713002000000_102.12.1615.58","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.jtos.2017.05.006","article-title":"TFOS DEWS II management and therapy report","volume":"15","author":"Jones","year":"2017","journal-title":"Ocul Surf"},{"key":"2020050713002000000_102.12.1615.59","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/S0002-9394(03)00903-6","article-title":"The effect of punctal occlusion on wavefront aberrations in dry eye patients after laser in situ keratomileusis","volume":"137","author":"Huang","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"2020050713002000000_102.12.1615.60","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.021"},{"key":"2020050713002000000_102.12.1615.61","doi-asserted-by":"crossref","first-page":"538","DOI":"10.4193\/Rhino11.042","article-title":"Development and validation of a symptom questionnaire for recording outcomes in adult lacrimal surgery","volume":"49","author":"Mistry","year":"2011","journal-title":"Rhinology"},{"key":"2020050713002000000_102.12.1615.62","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/IOP.0000000000000660","article-title":"Assessing the outcomes of powered endoscopic dacryocystorhinostomy in adults using the Lacrimal Symptom (Lac-Q) Questionnaire","volume":"33","author":"Ali","year":"2017","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"2020050713002000000_102.12.1615.63","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-4486.2006.01278.x"},{"key":"2020050713002000000_102.12.1615.64","doi-asserted-by":"crossref","first-page":"446","DOI":"10.4193\/Rhino10.069","article-title":"Symptom score questionnaire for nasolacrimal duct obstruction in adults\u2013a novel tool to assess the outcome after endoscopic dacryocystorhinostomy","volume":"48","author":"Smirnov","year":"2010","journal-title":"Rhinology"},{"key":"2020050713002000000_102.12.1615.65","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-306496"},{"key":"2020050713002000000_102.12.1615.66","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1038\/eye.2013.96","article-title":"Patient satisfaction following endoscopic endonasal dacryocystorhinostomy: a quality of life study","volume":"27","author":"Jutley","year":"2013","journal-title":"Eye"},{"key":"2020050713002000000_102.12.1615.67","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.119834"},{"key":"2020050713002000000_102.12.1615.68","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.01.022"},{"key":"2020050713002000000_102.12.1615.69","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.ajo.2017.06.022","article-title":"Quality of vision in eyes with epiphora undergoing lacrimal passage intubation","volume":"181","author":"Koh","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"2020050713002000000_102.12.1615.70","doi-asserted-by":"crossref","unstructured":"Chan TCY , Wan KH , Shih KC , et al . Advances in dry eye imaging: the present and beyond. Br J Ophthalmol 2018;102:295-301. Oct 5.doi:10.1136\/bjophthalmol-2017-310759","DOI":"10.1136\/bjophthalmol-2017-310759"},{"key":"2020050713002000000_102.12.1615.71","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.03.028"},{"key":"2020050713002000000_102.12.1615.72","doi-asserted-by":"publisher","DOI":"10.1007\/BF00936521"},{"key":"2020050713002000000_102.12.1615.73","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000177803.74120.6f"},{"key":"2020050713002000000_102.12.1615.74","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/S0002-9394(14)72775-8","article-title":"The effect of artificial tears on computer-assisted corneal topography in normal eyes and after penetrating keratoplasty","volume":"119","author":"Pavlopoulos","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"2020050713002000000_102.12.1615.75","doi-asserted-by":"publisher","DOI":"10.1159\/000048310"},{"key":"2020050713002000000_102.12.1615.76","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31821ea667"},{"key":"2020050713002000000_102.12.1615.77","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12409"},{"key":"2020050713002000000_102.12.1615.78","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2009.00373.x"},{"key":"2020050713002000000_102.12.1615.79","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01230.x"},{"key":"2020050713002000000_102.12.1615.80","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/OPX.0000000000000101","article-title":"Effects of sodium hyaluronate on wavefront aberrations in dry eye patients","volume":"91","author":"Lekhanont","year":"2014","journal-title":"Optom Vis Sci"}],"container-title":["British Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bjophthalmol-2018-312333","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T20:15:24Z","timestamp":1661458524000},"score":1,"resource":{"primary":{"URL":"https:\/\/bjo.bmj.com\/lookup\/doi\/10.1136\/bjophthalmol-2018-312333"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,15]]},"references-count":80,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,11,22]]},"published-print":{"date-parts":[[2018,12]]}},"alternative-id":["10.1136\/bjophthalmol-2018-312333"],"URL":"https:\/\/doi.org\/10.1136\/bjophthalmol-2018-312333","relation":{},"ISSN":["0007-1161","1468-2079"],"issn-type":[{"value":"0007-1161","type":"print"},{"value":"1468-2079","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,15]]}}}