{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T16:45:04Z","timestamp":1787244304439,"version":"build-2736575974"},"reference-count":35,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T00:00:00Z","timestamp":1640304000000},"content-version":"unspecified","delay-in-days":23,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Gastroenterol"],"accepted":{"date-parts":[[2021,11,16]]},"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>\n                      Transjugular intrahepatic portosystemic shunt (TIPS) placement is a well-established but technically challenging procedure for the management of sequelae of end-stage liver disease. Performed essentially blindly, traditional fluoroscopically guided TIPS placement requires multiple needle passes and prolonged radiation exposure to achieve successful portal venous access, thus increasing procedure time and the risk of periprocedural complications. Several advanced image-guided portal access techniques, including intracardiac echocardiography (ICE)-guided access, cone-beam CT (CBCT)-guided access and wire-targeting access techniques, can serve as alternatives to traditional CO\n                      <jats:sub>2<\/jats:sub>\n                      portography-based TIPS creation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A literature search was performed on the electronic databases including MEDLINE and Embase, from 2000 to the present to identify all relevant studies. The reference list also included studies identified manually, and studies referenced for other purposes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Findings<\/jats:title>\n                    <jats:p>The main benefit of these advanced access techniques is that they allow the operator to avoid essentially blind portal punctures, and the ability to visualise the target, thus reducing the number of required needle passes. Research has shown that ICE-guided access can decrease the radiation exposure, procedure time and complication rate in patients undergoing TIPS placement. This technique is particularly useful in patients with challenging portal venous anatomy. However, ICE-guided access requires additional equipment and possibly a second operator. Other studies have shown that CBCT-guided access, when compared with traditional fluoroscopy-guided access, provides superior visualisation of the anatomy with similar amount of radiation exposure and procedure time. The wire-targeting technique, on the other hand, appears to offer reductions in procedure time and radiation exposure by enabling real-time guidance. However, this technique necessitates percutaneous injury to the liver parenchyma in order to place the target wire.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Advanced portal access techniques have certain advantages over the traditional fluoroscopically guided TIPS access. To date, few studies have compared these advanced guided access options, and further research is required.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjgast-2021-000815","type":"journal-article","created":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T11:41:16Z","timestamp":1640346076000},"page":"e000815","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":18,"title":["Advanced portal venous access techniques for transjugular intrahepatic portosystemic shunt placement"],"prefix":"10.1136","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0856-6928","authenticated-orcid":false,"given":"Sasan","family":"Partovi","sequence":"first","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Shwaiki","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Basem","family":"Rashwan","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christer","family":"Ruff","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd","family":"Grozinger","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sameer","family":"Gadani","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diane","family":"Szaflarski","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dustin","family":"Thompson","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guiseppe","family":"D'Amico","sequence":"additional","affiliation":[{"name":"Department of Transplant Surgery, Digestive Disease and Surgery Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abraham","family":"Levitin","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baljendra","family":"Kapoor","sequence":"additional","affiliation":[{"name":"Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2021,12,24]]},"reference":[{"key":"2025073013370378000_8.1.e000815.1","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1055\/s-0037-1609042","article-title":"Transjugular intrahepatic portosystemic shunt in ascites: updates","volume":"01","author":"Trieu","year":"2017","journal-title":"Dig Dis Interv"},{"key":"2025073013370378000_8.1.e000815.2","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1055\/s-0038-1629915","article-title":"TIPS in the treatment of variceal bleeding","volume":"01","author":"Morrison","year":"2017","journal-title":"Dig Dis Interv"},{"key":"2025073013370378000_8.1.e000815.3","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1055\/s-0038-1629917","article-title":"Early transjugular intrahepatic portosystemic shunt (tips) placement in patients with cirrhosis and variceal bleeding","volume":"01","author":"Lang","year":"2017","journal-title":"Dig Dis Interv"},{"key":"2025073013370378000_8.1.e000815.4","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1055\/s-0040-1712117","article-title":"Transjugular intrahepatic portosystemic shunts in high-risk patients","volume":"04","author":"Shin","year":"2020","journal-title":"Dig Dis Interv"},{"key":"2025073013370378000_8.1.e000815.5","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.4819"},{"key":"2025073013370378000_8.1.e000815.6","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/67632946"},{"key":"2025073013370378000_8.1.e000815.7","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000242185.26944.60"},{"key":"2025073013370378000_8.1.e000815.8","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1007\/s00270-003-2634-9","article-title":"Intravascular ultrasound guidance for transjugular intrahepatic portosystemic shunt procedure in a swine model","volume":"27","author":"Kew","year":"2004","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2025073013370378000_8.1.e000815.9","doi-asserted-by":"publisher","DOI":"10.1053\/j.tvir.2016.01.001"},{"key":"2025073013370378000_8.1.e000815.10","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/S1089-2516(98)80028-0","article-title":"TIPS technique","volume":"1","author":"Kerlan","year":"1998","journal-title":"Tech Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.11","doi-asserted-by":"publisher","DOI":"10.1007\/BF02641894"},{"key":"2025073013370378000_8.1.e000815.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhep.2011.12.034"},{"key":"2025073013370378000_8.1.e000815.13","article-title":"Portal vein thrombosis: diagnosis and endovascular management","volume":"12","author":"Ju","year":"2021","journal-title":"Rofo"},{"key":"2025073013370378000_8.1.e000815.14","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1053\/j.tvir.2013.02.010","article-title":"Nonvascular and portal vein applications of cone-beam computed tomography: current status","volume":"16","author":"Kapoor","year":"2013","journal-title":"Tech Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.15","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.1982.4307545"},{"key":"2025073013370378000_8.1.e000815.16","unstructured":"Heran NS , Song JK , Namba K , et al . The utility of DynaCT in neuroendovascular procedures 2006;27:330\u20132."},{"key":"2025073013370378000_8.1.e000815.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2008.02.002"},{"key":"2025073013370378000_8.1.e000815.18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2009.04.059"},{"key":"2025073013370378000_8.1.e000815.19","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.ejrad.2018.06.025","article-title":"3D C-Arm cone beam CT for targeting the portal vein during TIPS: initial clinical experience","volume":"106","author":"Chivot","year":"2018","journal-title":"Eur J Radiol"},{"key":"2025073013370378000_8.1.e000815.20","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.diii.2016.06.015","article-title":"Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement","volume":"97","author":"Rouabah","year":"2016","journal-title":"Diagn Interv Imaging"},{"key":"2025073013370378000_8.1.e000815.21","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s00270-014-1035-6","article-title":"Impact of anatomical, procedural, and operator skill factors on the success and duration of Fluoroscopy-Guided transjugular intrahepatic portosystemic shunt","volume":"38","author":"Marquardt","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2025073013370378000_8.1.e000815.22","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1016\/j.jvir.2012.08.023","article-title":"Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance","volume":"23","author":"Farsad","year":"2012","journal-title":"J Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.23","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1016\/j.jvir.2016.01.137","article-title":"Intravascular ultrasound in the creation of transhepatic portosystemic shunts reduces needle passes, radiation dose, and procedure time: a retrospective study of a single-institution experience","volume":"27","author":"Kao","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.24","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1016\/j.jvir.2015.12.002","article-title":"Intravascular US-Guided portal vein access: improved procedural metrics during tips creation","volume":"27","author":"Gipson","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.25","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1016\/j.jvir.2016.05.010","article-title":"Utility of intravascular US-Guided portal vein access during transjugular intrahepatic portosystemic shunt creation: retrospective comparison with conventional technique in 109 patients","volume":"27","author":"Pillai","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.26","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.clinimag.2019.04.015","article-title":"Propensity-matched comparison of transjugular intrahepatic portosystemic shunt placement techniques: intracardiac echocardiography (ICE) versus fluoroscopic guidance","volume":"57","author":"Ramaswamy","year":"2019","journal-title":"Clin Imaging"},{"key":"2025073013370378000_8.1.e000815.27","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1055\/s-0040-1715875","article-title":"Intracardiac Echocardiography-Guided TIPS: a primer for new operators","volume":"37","author":"Grimsbo","year":"2020","journal-title":"Semin Intervent Radiol"},{"key":"2025073013370378000_8.1.e000815.28","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000208984.17697.58"},{"key":"2025073013370378000_8.1.e000815.29","doi-asserted-by":"crossref","first-page":"W11","DOI":"10.2214\/AJR.15.15210","article-title":"Real-Time 3D CT image guidance for transjugular intrahepatic portosystemic shunt creation using preoperative CT: a prospective feasibility study of 20 patients","volume":"208","author":"Luo","year":"2017","journal-title":"AJR Am J Roentgenol"},{"key":"2025073013370378000_8.1.e000815.30","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s00270-018-1877-4","article-title":"Clinical experience with real-time 3-D guidance based on C-Arm-Acquired cone-beam CT (CBCT) in transjugular intrahepatic portosystemic stent shunt (TIPSS) placement","volume":"41","author":"B\u00f6ning","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2025073013370378000_8.1.e000815.31","doi-asserted-by":"crossref","first-page":"4277","DOI":"10.1007\/s00330-016-4340-4","article-title":"Three-Dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: feasibility, technical success and procedural time","volume":"26","author":"Ketelsen","year":"2016","journal-title":"Eur Radiol"},{"key":"2025073013370378000_8.1.e000815.32","doi-asserted-by":"crossref","first-page":"3215","DOI":"10.1007\/s00330-018-5316-3","article-title":"Transjugular intrahepatic portosystemic shunt creation: three-dimensional roadmap versus CO\n                  2\n                wedged hepatic venography","volume":"28","author":"Luo","year":"2018","journal-title":"Eur Radiol"},{"key":"2025073013370378000_8.1.e000815.33","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1007\/s00270-015-1087-2","article-title":"C-Arm cone-beam volume CT in transjugular intrahepatic portosystemic shunt: initial clinical experience","volume":"38","author":"Luo","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2025073013370378000_8.1.e000815.34","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S1051-0443(92)72010-7","article-title":"Localization of the portal vein for transjugular catheterization: percutaneous placement of a metallic marker with real-time US guidance","volume":"3","author":"Harman","year":"1992","journal-title":"J Vasc Interv Radiol"},{"key":"2025073013370378000_8.1.e000815.35","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.2214\/AJR.20.23846","article-title":"Ultrasound-Guided portal vein access and percutaneous wire placement in the portal vein are associated with shorter procedure times and lower radiation doses during tips placement","volume":"216","author":"Cam","year":"2021","journal-title":"Am J Roentgenol"}],"container-title":["BMJ Open Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjgast-2021-000815","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T20:37:19Z","timestamp":1753907839000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopengastro.bmj.com\/lookup\/doi\/10.1136\/bmjgast-2021-000815"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12,24]]},"published-print":{"date-parts":[[2021,12]]}},"alternative-id":["10.1136\/bmjgast-2021-000815"],"URL":"https:\/\/doi.org\/10.1136\/bmjgast-2021-000815","relation":{},"ISSN":["2054-4774"],"issn-type":[{"value":"2054-4774","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12]]}}}