{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:14:52Z","timestamp":1792800892698,"version":"4.5.0"},"reference-count":29,"publisher":"BMJ","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2013,1,28]]},"published-print":{"date-parts":[[2013]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>In this method comparison study we compared blood lactate concentration measured using the Lactate Plus portable analyzer to lactate concentration measured by a reference analyzer, the YSI 2300.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>University campus in the USA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Participants<\/jats:title>\n                    <jats:p>Fifteen active men and women performed a discontinuous graded exercise test to volitional exhaustion on a motorised treadmill. Blood samples were taken via finger prick and collected in microcapillary tubes for analysis by the reference instrument at the end of each stage. Duplicate samples for the portable analyzer were either taken directly from the finger or from the micro capillary tubes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Primary outcome measurements<\/jats:title>\n                    <jats:p>Ordinary least products regressions were used to assess validity, reliability and bias in the portable analyzer. Lactate threshold was determined by visual inspection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Though measurements from both instruments were correlated (r=0.91), the differences between instruments had large variability (SD=1.45\u2005mM\/l) when blood was sampled directly from finger. This variability was reduced by \u223c95% when both instruments measured blood collected in the capillary tubes. As the proportional and fixed bias between instruments was small, there was no difference in estimates of the lactate threshold between instruments. Reliability for the portable instrument was strong (r=0.99, p&lt;0.05) with no proportional bias (slope=1.02) and small fixed bias (\u22120.19\u2005mM\/l).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The Lactate Plus analyzer provides accurate and reproducible measurements of blood lactate concentration that can be used to estimate workloads corresponding to blood lactate transitions or any absolute lactate concentrations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2012-001899","type":"journal-article","created":{"date-parts":[[2013,3,1]],"date-time":"2013-03-01T22:55:45Z","timestamp":1362178545000},"page":"e001899","source":"Crossref","is-referenced-by-count":105,"title":["A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer"],"prefix":"10.1136","volume":"3","author":[{"given":"Sarah","family":"Hart","sequence":"first","affiliation":[{"name":"Department of Applied Health Science, Wheaton College, Wheaton, Illinois, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathryn","family":"Drevets","sequence":"additional","affiliation":[{"name":"Department of Applied Health Science, Wheaton College, Wheaton, Illinois, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micah","family":"Alford","sequence":"additional","affiliation":[{"name":"Department of Applied Health Science, Wheaton College, Wheaton, Illinois, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda","family":"Salacinski","sequence":"additional","affiliation":[{"name":"Department of Kinesiology and Physical Education, Northern Illinois University, DeKalb, Illinois, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian E","family":"Hunt","sequence":"additional","affiliation":[{"name":"Department of Applied Health Science, Wheaton College, Wheaton, Illinois, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2013,2,27]]},"reference":[{"key":"2025121514524548000_3.2.e001899.1","first-page":"1040","article-title":"Serum lactate and base deficit as predictors of mortality in normotensive elderly blunt trauma patients","volume":"66","author":"Callaway","year":"2009","journal-title":"J Trauma-Injury Infect Crit Care"},{"key":"2025121514524548000_3.2.e001899.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.annemergmed.2010.10.016"},{"key":"2025121514524548000_3.2.e001899.3","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1515\/jpme.1998.26.2.83","article-title":"Quality assessment of two lactate test strip methods suitable for obstetric use","volume":"26","author":"Nordstrom","year":"1998","journal-title":"J Perinat Med"},{"key":"2025121514524548000_3.2.e001899.4","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1016\/j.clinbiochem.2008.08.088","article-title":"Comparison and validation of point of care lactate meters as a replacement for fetal pH measurement","volume":"41","author":"Ridenour","year":"2008","journal-title":"Clin Biochem"},{"key":"2025121514524548000_3.2.e001899.5","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s00421-009-1107-5","article-title":"Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer","volume":"107","author":"Baldari","year":"2009","journal-title":"Eur J Appl Physiol"},{"key":"2025121514524548000_3.2.e001899.6","doi-asserted-by":"publisher","DOI":"10.1016\/S1440-2440(03)80267-0"},{"key":"2025121514524548000_3.2.e001899.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijid.2008.03.007"},{"key":"2025121514524548000_3.2.e001899.8","doi-asserted-by":"publisher","DOI":"10.1007\/s004210050659"},{"key":"2025121514524548000_3.2.e001899.9","doi-asserted-by":"publisher","DOI":"10.1007\/s10545-005-0090-1"},{"key":"2025121514524548000_3.2.e001899.10","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s00421-010-1379-9","article-title":"Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus","volume":"109","author":"Tanner","year":"2010","journal-title":"Eur J Appl Physiol"},{"key":"2025121514524548000_3.2.e001899.11","doi-asserted-by":"publisher","DOI":"10.1152\/ajpendo.00303.2003"},{"key":"2025121514524548000_3.2.e001899.12","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1681.1997.tb01807.x"},{"key":"2025121514524548000_3.2.e001899.13","doi-asserted-by":"publisher","DOI":"10.1046\/j.1440-1681.2002.03686.x"},{"key":"2025121514524548000_3.2.e001899.14","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1152\/jappl.1985.59.6.1936","article-title":"Improved detection of lactate threshold during exercise using a log-log transformation","volume":"59","author":"Beaver","year":"1985","journal-title":"J Appl Physiol"},{"key":"2025121514524548000_3.2.e001899.15","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1249\/00005768-198502000-00005","article-title":"Anaerobic threshold: review of the concept and directions for future research","volume":"17","author":"Brooks","year":"1985","journal-title":"Med Sci Sports Exerc"},{"key":"2025121514524548000_3.2.e001899.16","doi-asserted-by":"publisher","DOI":"10.1097\/00005768-200111000-00007"},{"key":"2025121514524548000_3.2.e001899.17","first-page":"R94","article-title":"Fitting straight lines to experimental data","volume":"233","author":"Brace","year":"1977","journal-title":"Am J Physiol"},{"key":"2025121514524548000_3.2.e001899.18","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1055\/s-2007-1021263","article-title":"Exercise training at and above the lactate threshold in previously untrained women","volume":"13","author":"Weltman","year":"1992","journal-title":"Int J Sports Med"},{"key":"2025121514524548000_3.2.e001899.19","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1080\/17461390903567825","article-title":"Assessment of individual anaerobic threshold and stroking parameters in swimmers aged 10\u201311 years","volume":"10","author":"Fernandes","year":"2010","journal-title":"Eur J Sport Sci"},{"key":"2025121514524548000_3.2.e001899.20","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1519\/JSC.0b013e318225f395","article-title":"The influence of blood lactate sample site on exercise prescription","volume":"26","author":"Moran","year":"2012","journal-title":"J Strength Cond Res"},{"key":"2025121514524548000_3.2.e001899.21","doi-asserted-by":"crossref","first-page":"2082","DOI":"10.1152\/jappl.1985.58.6.2082","article-title":"Gas-exchange and lactate anaerobic thresholds\u2014interevaluator and intraevaluator agreement","volume":"58","author":"Gladden","year":"1985","journal-title":"J Appl Physiol"},{"key":"2025121514524548000_3.2.e001899.22","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1152\/jappl.1983.55.4.1178","article-title":"Anaerobic threshold\u2014problems of determination and validation","volume":"55","author":"Yeh","year":"1983","journal-title":"J Appl Physiol"},{"key":"2025121514524548000_3.2.e001899.23","first-page":"61e","article-title":"Characterization of the blood lactate curce and applicability of the Dmax model in a progressive protocol on treadmill","volume":"12","author":"de Oliveira Pires","year":"2006","journal-title":"Rev Bras Med Esporte"},{"key":"2025121514524548000_3.2.e001899.24","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1021309"},{"key":"2025121514524548000_3.2.e001899.25","first-page":"50","article-title":"The Dmax method does not produce a valid estimate of the lactate threshold","volume":"13","author":"Janeba","year":"2010","journal-title":"JEPonline"},{"key":"2025121514524548000_3.2.e001899.26","doi-asserted-by":"publisher","DOI":"10.1080\/02640410601128922"},{"key":"2025121514524548000_3.2.e001899.27","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1002\/mrm.1910220113","article-title":"pH-Lactate dissociation in neonatal anoxia: proton and 31P NMR spectroscopic studies in rat pups","volume":"22","author":"Hida","year":"1991","journal-title":"Magn Reson Med"},{"key":"2025121514524548000_3.2.e001899.28","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1111\/j.1471-4159.1987.tb13140.x","article-title":"Lactate and pH in the brain: association and dissociation in different pathophysiological states","volume":"48","author":"Paschen","year":"1987","journal-title":"J Neurochem"},{"key":"2025121514524548000_3.2.e001899.29","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/S0765-1597(00)80017-9","article-title":"Determination of lactic and ventilatory thresholds. Position of the Societe Francaise de Medecine du Sport (French Sports Medicine Society)","volume":"15","author":"Vallier","year":"2000","journal-title":"Sci Sports"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2012-001899","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T22:52:56Z","timestamp":1765839176000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2012-001899"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2013,2,27]]},"published-print":{"date-parts":[[2013]]}},"alternative-id":["10.1136\/bmjopen-2012-001899"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2012-001899","relation":{},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013]]}}}