{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T03:39:17Z","timestamp":1772163557923,"version":"3.50.1"},"reference-count":14,"publisher":"BMJ","issue":"7","license":[{"start":{"date-parts":[[2020,7,7]],"date-time":"2020-07-07T00:00:00Z","timestamp":1594080000000},"content-version":"unspecified","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2020,6,15]]},"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Single-arm feasibility study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>Emergency department and outpatient oncology clinic.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Participants<\/jats:title>\n                    <jats:p>Healthcare workers who have previously undergone N95 fit testing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions<\/jats:title>\n                    <jats:p>Fit testing of new iMASC system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Primary and secondary outcome measures<\/jats:title>\n                    <jats:p>Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21\u201365 years) with an average body mass index of 26.5 kg\/m\n                      <jats:sup>2<\/jats:sup>\n                      . The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2020-039120","type":"journal-article","created":{"date-parts":[[2020,7,8]],"date-time":"2020-07-08T05:16:09Z","timestamp":1594185369000},"page":"e039120","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":13,"title":["Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study"],"prefix":"10.1136","volume":"10","author":[{"given":"James D","family":"Byrne","sequence":"first","affiliation":[{"name":"Harvard Radiation Oncology Program, Brigham and Women's Hospital, Boston, Massachusetts, USA"},{"name":"David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adam J","family":"Wentworth","sequence":"additional","affiliation":[{"name":"David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"},{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter R","family":"Chai","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Brigham and Women\u2019s Hospital, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hen-Wei","family":"Huang","sequence":"additional","affiliation":[{"name":"David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"},{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sahab","family":"Babaee","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"},{"name":"Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Canchen","family":"Li","sequence":"additional","affiliation":[{"name":"David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah L","family":"Becker","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caitlynn","family":"Tov","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seokkee","family":"Min","sequence":"additional","affiliation":[{"name":"David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7851-4077","authenticated-orcid":false,"given":"Giovanni","family":"Traverso","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology, Brigham and Women's Hospital, Boston, Massachusetts, USA"},{"name":"Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2020,7,7]]},"reference":[{"key":"2025121221130610000_10.7.e039120.1","doi-asserted-by":"crossref","first-page":"e41","DOI":"10.1056\/NEJMp2006141","article-title":"Critical supply shortages - the need for ventilators and personal protective equipment during the Covid-19 pandemic","volume":"382","author":"Ranney","year":"2020","journal-title":"N Engl J Med"},{"key":"2025121221130610000_10.7.e039120.2","doi-asserted-by":"crossref","DOI":"10.1001\/jama.2020.5317","article-title":"Sourcing personal protective equipment during the COVID-19 pandemic","author":"Livingston","year":"2020","journal-title":"JAMA"},{"key":"2025121221130610000_10.7.e039120.3","doi-asserted-by":"crossref","DOI":"10.1001\/jama.2020.3972","article-title":"Supporting the health care workforce during the COVID-19 global epidemic","author":"Adams","year":"2020","journal-title":"JAMA"},{"key":"2025121221130610000_10.7.e039120.4","doi-asserted-by":"crossref","DOI":"10.1016\/S0140-6736(20)30644-9","article-title":"COVID-19: protecting health-care workers","volume":"395","year":"2020","journal-title":"Lancet"},{"key":"2025121221130610000_10.7.e039120.5","unstructured":"National Academies of Sciences, Engineering, and Medicine, Health and Medicine Division, Board on Health Sciences Policy, Committee on the Use of Elastomeric Respirators in Health Care . Reusable elastomeric respirators in health care: considerations for routine and surge use. Washington (DC): National Academies Press (US), 2018."},{"key":"2025121221130610000_10.7.e039120.6","doi-asserted-by":"publisher","DOI":"10.1183\/23120541.00168-2017"},{"key":"2025121221130610000_10.7.e039120.7","unstructured":"Occupational Safety and Health Standards . OSHA 1910.134 appendix A: fit testing procedures (mandatory), 2017."},{"key":"2025121221130610000_10.7.e039120.8","unstructured":"U.S. Department of Labor . Temporary enforcement guidance - healthcare respiratory protection annual fit-testing for N95 filtering Facepieces during the COVID-19 outbreak, 2020."},{"key":"2025121221130610000_10.7.e039120.9","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/S2213-2600(20)30134-X","article-title":"Rational use of face masks in the COVID-19 pandemic","volume":"8","author":"Feng","year":"2020","journal-title":"Lancet Respir Med"},{"key":"2025121221130610000_10.7.e039120.10","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2014-006577"},{"key":"2025121221130610000_10.7.e039120.11","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1111\/ijn.12354","article-title":"A novel approach to fit testing the N95 respirator in real time in a clinical setting","volume":"22","author":"Or","year":"2016","journal-title":"Int J Nurs Pract"},{"key":"2025121221130610000_10.7.e039120.12","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1086\/591860","article-title":"Respirator-fit testing: does it ensure the protection of healthcare workers against respirable particles carrying pathogens?","volume":"29","author":"Lee","year":"2008","journal-title":"Infect Control Hosp Epidemiol"},{"key":"2025121221130610000_10.7.e039120.13","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1086\/647195","article-title":"The effect of respirator training on the ability of healthcare workers to pass a qualitative fit test","volume":"17","author":"Hannum","year":"1996","journal-title":"Infect Control Hosp Epidemiol"},{"key":"2025121221130610000_10.7.e039120.14","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1080\/104732200301269","article-title":"Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks","volume":"15","author":"McKay","year":"2000","journal-title":"Appl Occup Environ Hyg"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2020-039120","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T05:13:14Z","timestamp":1765602794000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2020-039120"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":14,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2020,7,7]]},"published-print":{"date-parts":[[2020,7]]}},"alternative-id":["10.1136\/bmjopen-2020-039120"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2020-039120","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2020.04.03.20052688","asserted-by":"object"}]},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7]]}}}