{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T19:27:55Z","timestamp":1780082875246,"version":"3.54.0"},"reference-count":49,"publisher":"BMJ","issue":"6","license":[{"start":{"date-parts":[[2021,6,28]],"date-time":"2021-06-28T00:00:00Z","timestamp":1624838400000},"content-version":"unspecified","delay-in-days":27,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2021,4,6]]},"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The survival benefit of using mechanical circulatory support (MCS) in patients with acute myocardial infarction (AMI) is still controversial. It is necessary to explore the impact on clinical outcomes of MCS in patients with AMI undergoing stenting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Systematic review and meta-analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data sources<\/jats:title>\n                    <jats:p>Embase, Cochrane Library, Medline, PubMed, Web of Science, ClinicalTrials.gov and Clinicaltrialsregister.eu databases were searched from database inception to February 2021.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Eligibility criteria<\/jats:title>\n                    <jats:p>Randomised clinical trials (RCTs) on MCS use in patients with AMI undergoing stent implantation were included.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data extraction and synthesis<\/jats:title>\n                    <jats:p>Data were extracted and summarised independently by two reviewers. Risk ratios (RRs) and 95% CIs were calculated for clinical outcomes according to random-effects model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Twelve studies of 1497 patients with AMI were included, nine studies including 1382 patients compared MCS with non-MCS, and three studies including 115 patients compared percutaneous ventricular assist devices (pVADs) versus intra-aortic balloon pump (IABP). Compared with non-MCS, MCS was not associated with short-term (within 30 days) (RR=0.90; 95%\u2009CI 0.57 to 1.41; I\n                      <jats:sup>2<\/jats:sup>\n                      =46.8%) and long-term (at least 6 months) (RR=0.82; 95%\u2009CI 0.57 to 1.17; I\n                      <jats:sup>2<\/jats:sup>\n                      =37.6%) mortality reductions. In the subset of patients without cardiogenic shock (CS) compared with non-MCS, the patients with IABP treatment significantly had decreased long-term mortality (RR=0.49; 95%\u2009CI 0.27 to 0.90; I\n                      <jats:sup>2<\/jats:sup>\n                      =0), but without the short-term mortality reductions (RR=0.51; 95%\u2009CI 0.22 to 1.19; I\n                      <jats:sup>2<\/jats:sup>\n                      =17.9%). While in the patients with CS, the patients with MCS did not benefit from the short-term (RR=1.09; 95%\u2009CI 0.67 to 1.79; I\n                      <jats:sup>2<\/jats:sup>\n                      =46.6%) or long-term (RR=1.00; 95%\u2009CI 0.75 to 1.33; I\n                      <jats:sup>2<\/jats:sup>\n                      =22.1%) survival. Moreover, the application of pVADs increased risk of bleeding (RR=1.86; 95%\u2009CI 1.15 to 3.00; I\n                      <jats:sup>2<\/jats:sup>\n                      =15.3%) compared with IABP treatment (RR=1.86; 95%\u2009CI 1.15 to 3.00; I\n                      <jats:sup>2<\/jats:sup>\n                      =15.3%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In all patients with AMI undergoing stent implantation, the MCS use does not reduce all-cause mortality. Patients without CS can benefit from MCS regarding long-term survival, while patients with CS seem not.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2020-044072","type":"journal-article","created":{"date-parts":[[2021,6,29]],"date-time":"2021-06-29T13:00:19Z","timestamp":1624971619000},"page":"e044072","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":6,"title":["Effects of mechanical circulatory support devices in patients with acute myocardial infarction undergoing stent implantation: a systematic review and meta-analysis of randomised controlled trials"],"prefix":"10.1136","volume":"11","clinical-trial-number":[{"clinical-trial-number":"nct04184635","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct03637205","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct01633502","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct03813134","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct02301819","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct03729765","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct03431467","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct03947619","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Yunmin","family":"Shi","sequence":"first","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yujie","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuejing","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9866-1098","authenticated-orcid":false,"given":"Yan","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengqing","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanyuan","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suzhen","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weihong","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Yuan","sequence":"additional","affiliation":[{"name":"Clinical Research Center, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yao","family":"Lu","sequence":"additional","affiliation":[{"name":"Clinical Research Center, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7820-536X","authenticated-orcid":false,"given":"Jingjing","family":"Cai","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"},{"name":"Clinical Research Center, Third Xiangya Hospital, Central South University, Changsha, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2021,6,29]]},"reference":[{"key":"2025121601413123000_11.6.e044072.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.04.052"},{"key":"2025121601413123000_11.6.e044072.2","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1016\/S0140-6736(14)61889-4","article-title":"The war against heart failure: the Lancet lecture","volume":"385","author":"Braunwald","year":"2015","journal-title":"The Lancet"},{"key":"2025121601413123000_11.6.e044072.3","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn416"},{"key":"2025121601413123000_11.6.e044072.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.10.015"},{"key":"2025121601413123000_11.6.e044072.5","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn602"},{"key":"2025121601413123000_11.6.e044072.6","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehp292"},{"key":"2025121601413123000_11.6.e044072.7","first-page":"Cd007398","article-title":"Intra-Aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock","volume":"7","author":"Unverzagt","year":"2011","journal-title":"Cochrane database of syst rev"},{"key":"2025121601413123000_11.6.e044072.8","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1208410"},{"key":"2025121601413123000_11.6.e044072.9","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(13)61783-3"},{"key":"2025121601413123000_11.6.e044072.10","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0b013e3182742cf6"},{"key":"2025121601413123000_11.6.e044072.11","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu278"},{"key":"2025121601413123000_11.6.e044072.12","doi-asserted-by":"crossref","first-page":"e1173","DOI":"10.1097\/CCM.0000000000002692","article-title":"Extracorporeal circulatory support in acute coronary syndromes: a systematic review and meta-analysis","volume":"45","author":"Pavasini","year":"2017","journal-title":"Crit Care Med"},{"key":"2025121601413123000_11.6.e044072.13","doi-asserted-by":"crossref","first-page":"3523","DOI":"10.1093\/eurheartj\/ehx363","article-title":"Percutaneous short-term active mechanical support devices in cardiogenic shock: a systematic review and collaborative meta-analysis of randomized trials","volume":"38","author":"Thiele","year":"2017","journal-title":"Eur Heart J"},{"key":"2025121601413123000_11.6.e044072.14","first-page":"Cd007398","article-title":"Intra-Aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock","volume":"75","author":"Unverzagt","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"2025121601413123000_11.6.e044072.15","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.103.24.3019"},{"key":"2025121601413123000_11.6.e044072.16","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0108356","article-title":"Effects of intra-aortic balloon counterpulsation pump on mortality of acute myocardial infarction","volume":"9","author":"Ye","year":"2014","journal-title":"PLoS One"},{"key":"2025121601413123000_11.6.e044072.17","doi-asserted-by":"crossref","DOI":"10.1186\/s12872-016-0323-2","article-title":"The effectiveness of intra-aortic balloon pump for myocardial infarction in patients with or without cardiogenic shock: a meta-analysis and systematic review","volume":"16","author":"Zheng","year":"2016","journal-title":"BMC Cardiovasc Disord"},{"key":"2025121601413123000_11.6.e044072.18","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-151-4-200908180-00136"},{"key":"2025121601413123000_11.6.e044072.19","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928"},{"key":"2025121601413123000_11.6.e044072.20","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.327.7414.557"},{"key":"2025121601413123000_11.6.e044072.21","doi-asserted-by":"publisher","DOI":"10.1186\/s12916-016-0763-7"},{"key":"2025121601413123000_11.6.e044072.22","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00088-0"},{"key":"2025121601413123000_11.6.e044072.23","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.1998.1348"},{"key":"2025121601413123000_11.6.e044072.24","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.90.2.792"},{"key":"2025121601413123000_11.6.e044072.25","first-page":"128","article-title":"Intra-Aortic balloon pump counterpulsation in extensive myocardial infarction with persistent ischemia: the semper FI pilot study","volume":"95","author":"van Nunen","year":"2020","journal-title":"Catheter Cardiovasc Interv"},{"key":"2025121601413123000_11.6.e044072.26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2016.10.022"},{"key":"2025121601413123000_11.6.e044072.27","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehi161"},{"key":"2025121601413123000_11.6.e044072.28","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2011.1280"},{"key":"2025121601413123000_11.6.e044072.29","first-page":"2934","article-title":"Analysis on application timing of IABP in emergency PCI treatment of patients with combined acute myocardial infarction and cardiac shock","volume":"21","author":"Zhou","year":"2017","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"2025121601413123000_11.6.e044072.30","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1080\/AC.66.4.2126599","article-title":"Prophylactic intra-aortic balloon pump reduces C-reactive protein levels and early mortality in high-risk patients undergoing percutaneous coronary intervention","volume":"66","author":"Gu","year":"2011","journal-title":"Acta Cardiol"},{"key":"2025121601413123000_11.6.e044072.31","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181b78671"},{"key":"2025121601413123000_11.6.e044072.32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.05.065"},{"key":"2025121601413123000_11.6.e044072.33","first-page":"260","article-title":"[Impact of the intra-aortic balloon pump in the mortality due to cardiogenic shock secondary to acute myocardial infarction]","volume":"75","author":"Arias","year":"2005","journal-title":"Arch Cardiol Mex"},{"key":"2025121601413123000_11.6.e044072.34","first-page":"339","article-title":"Intra-Aortic counterpulsation does not improve coronary flow early after PCI in a high-risk group of patients: observations from a randomized trial to explore its mode of action","volume":"19","author":"Vijayalakshmi","year":"2007","journal-title":"J Invasive Cardiol"},{"key":"2025121601413123000_11.6.e044072.35","doi-asserted-by":"crossref","unstructured":"Lackermair K , Brunner S , Orban M , et al . Outcome of patients treated with extracorporeal life support in cardiogenic shock complicating acute myocardial infarction: 1-year result from the ECLS-Shock study. Clin Res in Cardiol 2020;136.doi:10.1007\/s00392-020-01778-8","DOI":"10.1007\/s00392-020-01778-8"},{"key":"2025121601413123000_11.6.e044072.36","first-page":"678","article-title":"Experimental augmentation of coronary flow by retardation of the arterial pressure pulse","volume":"34","author":"Kantrowitz","year":"1953","journal-title":"Surgery"},{"key":"2025121601413123000_11.6.e044072.37","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1161\/01.CIR.47.6.1197","article-title":"Intraaortic balloon pumping for control of recurrent myocardial ischemia","volume":"47","author":"Gold","year":"1973","journal-title":"Circulation"},{"key":"2025121601413123000_11.6.e044072.38","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1161\/01.CIR.68.1.117","article-title":"Augmentation of regional coronary blood flow by intra-aortic balloon counterpulsation in patients with unstable angina","volume":"68","author":"Fuchs","year":"1983","journal-title":"Circulation"},{"key":"2025121601413123000_11.6.e044072.39","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1186\/s13054-014-0662-2","article-title":"Prophylactic intra-aortic balloon counterpulsation in cardiac surgery: it is time for clear evidence","volume":"18","author":"Grieshaber","year":"2014","journal-title":"Crit Care"},{"key":"2025121601413123000_11.6.e044072.40","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.ijcard.2017.06.040","article-title":"Clinical benefit of drugs targeting mitochondrial function as an adjunct to reperfusion in ST-segment elevation myocardial infarction: a meta-analysis of randomized clinical trials","volume":"244","author":"Campo","year":"2017","journal-title":"Int J Cardiol"},{"key":"2025121601413123000_11.6.e044072.41","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2013-304198"},{"key":"2025121601413123000_11.6.e044072.42","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.181940"},{"key":"2025121601413123000_11.6.e044072.43","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-012-0523-4"},{"key":"2025121601413123000_11.6.e044072.44","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00227-1"},{"key":"2025121601413123000_11.6.e044072.45","doi-asserted-by":"publisher","DOI":"10.1001\/jama.294.4.448"},{"key":"2025121601413123000_11.6.e044072.46","doi-asserted-by":"publisher","DOI":"10.1097\/SHK.0b013e31824a67af"},{"key":"2025121601413123000_11.6.e044072.47","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1001\/jamainternmed.2015.0569","article-title":"Intra-Aortic balloon pump therapy for acute myocardial infarction: a meta-analysis","volume":"175","author":"Ahmad","year":"2015","journal-title":"JAMA Intern Med"},{"key":"2025121601413123000_11.6.e044072.48","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000017107","article-title":"Percutaneous mechanical circulatory support devices in high-risk patients undergoing percutaneous coronary intervention: a meta-analysis of randomized trials","volume":"98","author":"Shi","year":"2019","journal-title":"Medicine"},{"key":"2025121601413123000_11.6.e044072.49","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2015.01.081"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2020-044072","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T09:41:47Z","timestamp":1765878107000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2020-044072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":49,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021,6,29]]},"published-print":{"date-parts":[[2021,6]]}},"alternative-id":["10.1136\/bmjopen-2020-044072"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2020-044072","relation":{},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6]]}}}