{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T05:39:23Z","timestamp":1780637963037,"version":"3.54.1"},"reference-count":31,"publisher":"BMJ","issue":"8","license":[{"start":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T00:00:00Z","timestamp":1755561600000},"content-version":"unspecified","delay-in-days":18,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Interregional Group for Clinical Research and Innovation Grand Ouest","award":["RPM23T003"],"award-info":[{"award-number":["RPM23T003"]}]},{"name":"University hospital center of Orl\u00e9ans"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2025,7,30]]},"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Central venous catheters (CVCs) are commonly used in intensive care but should be removed as soon as they are no longer needed to reduce infection risk. Peripheral venous access then becomes necessary, but can be challenging due to oedema. Near-infrared light devices, simple non-invasive tools, may assist nurses in this procedure. We hypothesise that a near-infrared light device (AccuVein AV500) could improve the first-attempt success rate of peripheral venous catheter (PVC) placement in intensive care patients no longer requiring a central catheter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>This investigator-initiated, prospective, multicentre, randomised controlled superiority trial compares the near-infrared light device to the landmark approach for PVC insertion in critically ill patients with an existing CVC. A total of three hundred and eighty patients are to be randomised in two parallel groups with a stratification on centre and anticipated difficulty of peripheral venous access.<\/jats:p>\n                    <jats:p>The study objective is to compare the first-attempt success rate of PVC placement in adult critical care patients for whom a central catheter is no longer indicated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Ethics and dissemination<\/jats:title>\n                    <jats:p>The protocol and amendments have been approved by the French ethics committee (Comit\u00e9 de Protection des Personnes Sud Ouest et Outre Mer II, Toulouse, France, number 2023-A00429-36), and patients are included after informed consent. The results will be submitted for publication in peer-reviewed journals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration number<\/jats:title>\n                    <jats:p>\n                      Clinicaltrials.gov:\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"clintrialgov\" xlink:href=\"NCT06234293\">NCT06234293<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2025-102390","type":"journal-article","created":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T04:05:37Z","timestamp":1755576337000},"page":"e102390","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Near-infrared light devices versus landmark approach for peripheral venous access in the intensive care unit: protocol of a randomised controlled study"],"prefix":"10.1136","volume":"15","clinical-trial-number":[{"clinical-trial-number":"nct06234293","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-4818-0010","authenticated-orcid":false,"given":"Aude","family":"Ferrier","sequence":"first","affiliation":[{"name":"Centre Hospitalier Universitaire d'Orl\u00e9ans, Orl\u00e9ans, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Am\u00e9lie","family":"Despres","sequence":"additional","affiliation":[{"name":"Centre Hospitalier R\u00e9gional Universitaire de Tours, Tours, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aur\u00e9lie","family":"Brasselet","sequence":"additional","affiliation":[{"name":"Centre Hospitalier du Mans, Le Mans, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ga\u00ebtan","family":"Badre","sequence":"additional","affiliation":[{"name":"Centre Hospitalier de Chartres, Le Coudray, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathilde","family":"Wanneveich","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire d'Orl\u00e9ans, Orl\u00e9ans, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai-Anh","family":"Nay","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire d'Orl\u00e9ans, Orl\u00e9ans, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,8,18]]},"reference":[{"key":"2025123106471095000_15.8.e102390.1","doi-asserted-by":"crossref","DOI":"10.1186\/s13613-020-00713-4","article-title":"Expert consensus-based clinical practice guidelines management of intravascular catheters in the intensive care unit","volume":"10","author":"Timsit","year":"2020","journal-title":"Ann Intensive Care"},{"key":"2025123106471095000_15.8.e102390.2","unstructured":"Vascular access devices market size, share & trends analysis | global | 2024-2030 | medsuite | includes: implantable port market, port market, central venous catheter market, and 9 more. Idata research. Available: https:\/\/idataresearch.com\/product\/vascular-access-devices-market\/ [Accessed 27 Feb 2025]."},{"key":"2025123106471095000_15.8.e102390.3","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.pharma.2015.04.003","article-title":"Crit\u00e8res de choix d\u2019un cath\u00e9ter veineux central : points de vue de l\u2019anesth\u00e9siste-r\u00e9animateur et du pharmacien","volume":"73","author":"Novais","year":"2015","journal-title":"Annales Pharmaceutiques Fran\u00e7aises"},{"key":"2025123106471095000_15.8.e102390.4","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1500964"},{"key":"2025123106471095000_15.8.e102390.5","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1001\/jamainternmed.2023.8232","article-title":"Complication Rates of Central Venous Catheters: A Systematic Review and Meta-Analysis","volume":"184","author":"Teja","year":"2024","journal-title":"JAMA Intern Med"},{"key":"2025123106471095000_15.8.e102390.6","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1007\/s12630-010-9348-7","article-title":"Evaluation of unnecessary central venous catheters in critically ill patients: a prospective observational study","volume":"57","author":"Cload","year":"2010","journal-title":"Can J Anesth\/J Can Anesth"},{"key":"2025123106471095000_15.8.e102390.7","doi-asserted-by":"publisher","DOI":"10.1053\/jhin.2002.1349"},{"key":"2025123106471095000_15.8.e102390.8","doi-asserted-by":"crossref","DOI":"10.1186\/s12879-019-4505-2","article-title":"Blood stream infections associated with central and peripheral venous catheters","volume":"19","author":"Ruiz-Giardin","year":"2019","journal-title":"BMC Infect Dis"},{"key":"2025123106471095000_15.8.e102390.9","doi-asserted-by":"publisher","DOI":"10.4065\/81.9.1159"},{"key":"2025123106471095000_15.8.e102390.10","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181d4502e"},{"key":"2025123106471095000_15.8.e102390.11","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1007\/s13546-015-1063-5","article-title":"Voies veineuses p\u00e9riph\u00e9riques et risque d\u2019infections acquises en r\u00e9animation","volume":"24","author":"Messika","year":"2015","journal-title":"R\u00e9animation"},{"key":"2025123106471095000_15.8.e102390.12","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/cix562"},{"key":"2025123106471095000_15.8.e102390.13","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2018-022278","article-title":"Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics","volume":"9","author":"Carr","year":"2019","journal-title":"BMJ Open"},{"key":"2025123106471095000_15.8.e102390.14","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1016\/j.ajem.2014.07.008","article-title":"Risk factors associated with difficult venous access in adult ED patients","volume":"32","author":"Fields","year":"2014","journal-title":"Am J Emerg Med"},{"key":"2025123106471095000_15.8.e102390.15","doi-asserted-by":"crossref","DOI":"10.1186\/s13613-022-01009-5","article-title":"Risk factors for peripheral intravascular catheter-related phlebitis in critically ill patients: analysis of 3429 catheters from 23 Japanese intensive care units","volume":"12","author":"Yasuda","year":"2022","journal-title":"Ann Intensive Care"},{"key":"2025123106471095000_15.8.e102390.16","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e31828a42c5"},{"key":"2025123106471095000_15.8.e102390.17","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1007\/s12098-022-04216-x","article-title":"Comparison of LED-Based Transillumination Device with Traditional Vein Viewing Methods for Difficult Intravenous Cannulation in Indian Children: A Nonrandomized Controlled Trial","volume":"90","author":"Dutt","year":"2023","journal-title":"Indian J Pediatr"},{"key":"2025123106471095000_15.8.e102390.18","doi-asserted-by":"crossref","first-page":"1975","DOI":"10.1007\/s00431-016-2796-5","article-title":"Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis","volume":"175","author":"Park","year":"2016","journal-title":"Eur J Pediatr"},{"key":"2025123106471095000_15.8.e102390.19","doi-asserted-by":"publisher","DOI":"10.1007\/s00431-012-1713-9"},{"key":"2025123106471095000_15.8.e102390.20","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2012.03896.x"},{"key":"2025123106471095000_15.8.e102390.21","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12294"},{"key":"2025123106471095000_15.8.e102390.22","doi-asserted-by":"publisher","DOI":"10.1038\/jp.2011.129"},{"key":"2025123106471095000_15.8.e102390.23","doi-asserted-by":"crossref","first-page":"2747","DOI":"10.1007\/s00431-022-04480-1","article-title":"Near-infrared system\u2019s efficiency for peripheral intravenous cannulation in a level III neonatal intensive care unit: a cross-sectional study","volume":"181","author":"Ferrario","year":"2022","journal-title":"Eur J Pediatr"},{"key":"2025123106471095000_15.8.e102390.24","doi-asserted-by":"crossref","first-page":"105179","DOI":"10.1016\/j.nedt.2021.105179","article-title":"Does the use of infrared technology (AccuVein AV-500\u00ae) for Peripheral Intravenous Cannulation (PIVC) increase the success rate in nursing students? A randomized controlled trial","volume":"108","author":"Y\u0131lmaz","year":"2022","journal-title":"Nurse Educ Today"},{"key":"2025123106471095000_15.8.e102390.25","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1111\/acem.12437","article-title":"Efficacy of AccuVein to facilitate peripheral intravenous placement in adults presenting to an emergency department: a randomized clinical trial","volume":"21","author":"Aulagnier","year":"2014","journal-title":"Acad Emerg Med"},{"key":"2025123106471095000_15.8.e102390.26","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1111\/hae.12513","article-title":"Prospective evaluation of venous access difficulty and a near-infrared vein visualizer at four French haemophilia treatment centres","volume":"21","author":"Guillon","year":"2015","journal-title":"Haemophilia"},{"key":"2025123106471095000_15.8.e102390.27","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s40520-016-0547-0","article-title":"Effects of a new device to guide venous puncture in elderly critically ill patients: results of a pilot randomized study","volume":"29","author":"Fumagalli","year":"2017","journal-title":"Aging Clin Exp Res"},{"key":"2025123106471095000_15.8.e102390.28","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-158-3-201302050-00583"},{"key":"2025123106471095000_15.8.e102390.29","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2017-020220","article-title":"Ultrasound-guided versus landmark approach for peripheral intravenous access by critical care nurses: a randomised controlled study","volume":"8","author":"Bridey","year":"2018","journal-title":"BMJ Open"},{"key":"2025123106471095000_15.8.e102390.30","doi-asserted-by":"publisher","DOI":"10.1378\/chest.11-2054"},{"key":"2025123106471095000_15.8.e102390.31","doi-asserted-by":"crossref","first-page":"25152459231187531","DOI":"10.1177\/25152459231187531","article-title":"Tutorial: Power Analyses for Interaction Effects in Cross-Sectional Regressions","volume":"6","author":"Baranger","year":"2023","journal-title":"Adv Methods Pract Psychol Sci"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2025-102390","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T14:49:02Z","timestamp":1767192542000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2025-102390"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":31,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8,18]]},"published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1136\/bmjopen-2025-102390"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2025-102390","relation":{},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8]]}}}