{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T14:21:16Z","timestamp":1788531676468,"version":"build-2803163510"},"reference-count":34,"publisher":"BMJ","issue":"9","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"unspecified","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2026,8,26]]},"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>The aim of this systematic review protocol is to provide the current reported level of diagnostic performance of ultra-low field MRI (ULF-MRI) in brain imaging of both paediatrics (including neonates and infants) and adults from a range of neurological conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>We will use the population\/problem, intervention, comparison and outcome framework to break down the keywords to search PubMed, Medline, CINHAL, Embase, Web of Science, Scopus, Cochrane Central Register of Controlled Trials and Google Scholar without restriction of geographical location, study design and publication status. Other sources such as the reference list of selected studies will also be searched, and the search will be documented with a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow chart. The Quality Assessment of Diagnostic Accuracy Studies 3 tool will be used to assess the quality of the retrieved studies. After screening the studies, a meta-analysis for the primary outcome of individual and pooled diagnostic accuracy will be conducted using Meta-DiSc V1.4. Results expressed as forest plots, pooled heterogeneity values, 95% CIs, probability values and summary receiver operating characteristic curve plots will be used for data synthesis. The review commenced in January 2026 and is anticipated to conclude in June 2026. At the time of protocol submission, study identification, screening, data extraction, quality assessment and evidence synthesis have not yet commenced.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Ethics and dissemination<\/jats:title>\n                    <jats:p>The results of this systematic review will be disseminated in a peer-reviewed journal and presented at a relevant conference. Data do not include animal or human participant recruitment or personal individual data. All data are already published in the public domain; therefore, ethical approval is not required.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>PROSPERO registration number<\/jats:title>\n                    <jats:p>PROSPERO 1308164<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2026-118511","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:41:14Z","timestamp":1788529274000},"page":"e118511","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Diagnostic performance of ultra-low field neurological magnetic resonance imaging: a systematic review protocol"],"prefix":"10.1136","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5598-3890","authenticated-orcid":false,"given":"Paul","family":"Lockwood","sequence":"first","affiliation":[{"name":"School of Nursing, Midwifery, Allied and Public Health, Canterbury Christ Church University, Canterbury, Kent, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Barrett","sequence":"additional","affiliation":[{"name":"Radiology, Dartford and Gravesham NHS Trust, Dartford, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"2026090405502167000_16.9.e118511.1","unstructured":"British Institute of Radiology . MR safety: static magnetic field. London, 2018."},{"key":"2026090405502167000_16.9.e118511.2","doi-asserted-by":"publisher","DOI":"10.1177\/0272989X9101100203"},{"key":"2026090405502167000_16.9.e118511.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-9260(05)83184-8"},{"key":"2026090405502167000_16.9.e118511.4","unstructured":"Cooley CZ , McDaniel PC , Stockmann JP , et al . A portable brain MRI scanner for underserved settings and point-of-care imaging. ArXiv Preprint ArXiv 2020;200413183."},{"key":"2026090405502167000_16.9.e118511.5","doi-asserted-by":"crossref","DOI":"10.1016\/j.eclinm.2023.102253","article-title":"Development of neonatal-specific sequences for portable ultralow field magnetic resonance brain imaging: a prospective, single-centre, cohort study","volume":"65","author":"Cawley","year":"2023","journal-title":"EClinicalMedicine"},{"key":"2026090405502167000_16.9.e118511.6","doi-asserted-by":"crossref","first-page":"111929","DOI":"10.1016\/j.ejrad.2025.111929","article-title":"Retrospective comparison of routine brain MRI scans in patients at 0.55 T and 1.5\/3T","volume":"184","author":"Lavrova","year":"2025","journal-title":"Eur J Radiol"},{"key":"2026090405502167000_16.9.e118511.7","doi-asserted-by":"crossref","unstructured":"Lepore N , Linguraru MG . Low field pediatric brain magnetic resonance image segmentation and quality assurance. First MICCAI Challenge, LISA 2024, Held in Conjunction with MICCAI 2024; 2024","DOI":"10.1007\/978-3-031-83008-2"},{"key":"2026090405502167000_16.9.e118511.8","doi-asserted-by":"crossref","DOI":"10.1002\/hbm.70443","article-title":"Feasibility and Validity of Ultra-Low-Field MRI for Measurement of Regional Infant Brain Volumes in Structures Associated With Antenatal Maternal Anemia","volume":"47","author":"Ringshaw","year":"2026","journal-title":"Hum Brain Mapp"},{"key":"2026090405502167000_16.9.e118511.9","doi-asserted-by":"crossref","unstructured":"Deoni SC , Burton P , Beauchemin J , et al . Neuroimaging and cognitive testing in healthy aging adults using a portable low-field mri scanner and web-based assessment. In Review 2022. doi:10.21203\/rs.3.rs-2002708\/v1","DOI":"10.21203\/rs.3.rs-2002708\/v1"},{"key":"2026090405502167000_16.9.e118511.10","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1007\/s12028-025-02327-9","article-title":"Feasibility and Clinical Utility of Low-Field Magnetic Resonance Imaging in Critically Ill Children: An Experience from Pakistan","volume":"44","author":"Hilal","year":"2026","journal-title":"Neurocrit Care"},{"key":"2026090405502167000_16.9.e118511.11","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.124.069187"},{"key":"2026090405502167000_16.9.e118511.12","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.122.029242","article-title":"Identification of White Matter Hyperintensities in Routine Emergency Department Visits Using Portable Bedside Magnetic Resonance Imaging","volume":"12","author":"de Havenon","year":"2023","journal-title":"J Am Heart Assoc"},{"key":"2026090405502167000_16.9.e118511.13","doi-asserted-by":"crossref","DOI":"10.1007\/s00415-025-12938-z","article-title":"Portable ultra-low-field MRI for progressive multifocal leukoencephalopathy: Case studies, sensitivity, and potential applications","volume":"272","author":"Okar","year":"2025","journal-title":"J Neurol"},{"key":"2026090405502167000_16.9.e118511.14","unstructured":"National Institute for Health Research . A brief guide to patient and public involvement and qualitative methods within health and social care research. 2021."},{"key":"2026090405502167000_16.9.e118511.15","doi-asserted-by":"crossref","DOI":"10.1186\/s40900-024-00617-8","article-title":"Ethical considerations in public engagement: developing tools for assessing the boundaries of research and involvement","volume":"10","author":"Garcia-Iglesias","year":"2024","journal-title":"Res Involv Engagem"},{"key":"2026090405502167000_16.9.e118511.16","unstructured":"National institute for health research . NIHR co-production in action \u2013 number one. 2021."},{"key":"2026090405502167000_16.9.e118511.17","unstructured":"Society and College of Radiographers . Patient public and practitioner partnerships within imaging and radiotherapy: guiding principles. London, 2018."},{"key":"2026090405502167000_16.9.e118511.18","unstructured":"National Institute for Health and Care Research . Briefing note five: how to involve members of the public in research uk standards for public involvement. London, 2021."},{"key":"2026090405502167000_16.9.e118511.19","unstructured":"Coldham T . Guidance on co-producing a research project. 2021."},{"key":"2026090405502167000_16.9.e118511.20","unstructured":"Turk A , Boylan A , Locock L . A Researcher\u2019s Guide to Patient and Public Involvement. Oxford, 2017."},{"key":"2026090405502167000_16.9.e118511.21","doi-asserted-by":"crossref","first-page":"S40","DOI":"10.1016\/j.radi.2023.01.012","article-title":"An exploration of values-based radiography from the perspective of the service user","volume":"29 Suppl 1","author":"Newton-Hughes","year":"2023","journal-title":"Radiography (Lond)"},{"key":"2026090405502167000_16.9.e118511.22","doi-asserted-by":"publisher","DOI":"10.1016\/S1532-3382(01)70024-3"},{"key":"2026090405502167000_16.9.e118511.23","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1148\/rg.2015150112","article-title":"Statistics 101 for Radiologists","volume":"35","author":"Anvari","year":"2015","journal-title":"Radiographics"},{"key":"2026090405502167000_16.9.e118511.24","doi-asserted-by":"crossref","first-page":"548","DOI":"10.7326\/ANNALS-25-02104","article-title":"QUADAS-3: A Revised Tool for the Quality Assessment of Diagnostic Test Accuracy Studies","volume":"179","author":"Whiting","year":"2026","journal-title":"Ann Intern Med"},{"key":"2026090405502167000_16.9.e118511.25","unstructured":"Joanna Briggs Institute . Critical appraisal tools. Joanna Briggs Institute\u2019s critical appraisal checklists. Available: https:\/\/jbi.global\/critical-appraisal-tools [Accessed 16 Jan 2023]."},{"key":"2026090405502167000_16.9.e118511.26","doi-asserted-by":"crossref","DOI":"10.1186\/1471-2288-6-31","article-title":"Meta-DiSc: a software for meta-analysis of test accuracy data","volume":"6","author":"Zamora","year":"2006","journal-title":"BMC Med Res Methodol"},{"key":"2026090405502167000_16.9.e118511.27","doi-asserted-by":"crossref","DOI":"10.1186\/s12874-022-01788-2","article-title":"Meta-DiSc 2.0: a web application for meta-analysis of diagnostic test accuracy data","volume":"22","author":"Plana","year":"2022","journal-title":"BMC Med Res Methodol"},{"key":"2026090405502167000_16.9.e118511.28","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pcbi.1011461","article-title":"Ten simple rules for interpreting and evaluating a meta-analysis","volume":"19","author":"Carlson","year":"2023","journal-title":"PLoS Comput Biol"},{"key":"2026090405502167000_16.9.e118511.29","unstructured":"Information Commissioner\u2019s Office . What is personal data?. guide to the general data protection regulation (GDPR). Available: https:\/\/ico.org.uk\/for-organisations\/guide-to-data-protection\/guide-to-the-general-data-protection-regulation-gdpr\/what-is-personal-data\/ [Accessed 17 Oct 2022]."},{"key":"2026090405502167000_16.9.e118511.30","doi-asserted-by":"crossref","unstructured":"UK Government . The Data Protection Act 2018: Chapter 2 The GDPR. England: UK Government, 2018.","DOI":"10.1016\/S1353-4858(18)30020-5"},{"key":"2026090405502167000_16.9.e118511.31","doi-asserted-by":"crossref","first-page":"S31","DOI":"10.1192\/bjo.2024.138","article-title":"A Systematic Review of the Use of Portable Ultra-Low-Field Magnetic Resonance Imaging in Non-Acute Brain Imaging and Its Potential Use in Dementia Assessment","volume":"10","author":"Dobrzanski","year":"2024","journal-title":"BJPsych open"},{"key":"2026090405502167000_16.9.e118511.32","doi-asserted-by":"crossref","DOI":"10.3389\/fnimg.2025.1588487","article-title":"AI improves consistency in regional brain volumes measured in ultra-low-field MRI and 3T MRI","volume":"4","author":"Islam","year":"2025","journal-title":"Front Neuroimaging"},{"key":"2026090405502167000_16.9.e118511.33","doi-asserted-by":"crossref","unstructured":"Wang X , Lyul M . Infant Hippocampal Segmentation in Ultra-Low-Field MRI Using External. Low Field Pediatric Brain Magnetic Resonance Image Segmentation and Quality Assurance: First MICCAI Challenge,. LISA 2024, Held in Conjunction with MICCAI 2024; 2024:28.","DOI":"10.1007\/978-3-031-83008-2_3"},{"key":"2026090405502167000_16.9.e118511.34","doi-asserted-by":"crossref","unstructured":"Zhou W , Li J , Wang X , et al . Infant hippocampal segmentation in ultra-low-field mri using external datasets with diverse field strengths. In: MICCAI Challenge on Low Field Pediatric Brain Magnetic Resonance Image Segmentation and Quality Assurance. Springer Nature Switzerland Cham, 2024: 28\u201337.","DOI":"10.1007\/978-3-031-83008-2_3"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2026-118511","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:41:17Z","timestamp":1788529277000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2026-118511"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":34,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9,4]]},"published-print":{"date-parts":[[2026,9]]}},"alternative-id":["10.1136\/bmjopen-2026-118511"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2026-118511","relation":{},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9]]}}}