{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T13:24:45Z","timestamp":1791811485801,"version":"4.3.4"},"reference-count":9,"publisher":"BMJ","issue":"7","license":[{"start":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T00:00:00Z","timestamp":1784764800000},"content-version":"unspecified","delay-in-days":22,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open"],"accepted":{"date-parts":[[2026,6,29]]},"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Short peripheral catheters (SPCs) are the most frequently used vascular access devices in neonates but are associated with complications and limited dwell times. International guidelines recommend using the smallest appropriate catheter gauge, yet 24G SPCs remain the default choice in many neonatal intensive care units (NICUs) while 26G SPCs are less often used because of concerns about flow adequacy particularly during blood transfusions. Evidence directly comparing these gauges in neonates is limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a retrospective cohort study in a tertiary NICU and national referral centre for high-risk neonatal care in Doha, Qatar. Data were collected between 1 August 2018 and 31 December 2023. Eligible participants were neonates (0\u201328 days) who received at least one SPC insertion. Data extracted included demographics, catheter characteristics, dwell time, complications and reasons for removal. Analyses were performed at the catheter episode level. Dwell times were analysed using Kaplan\u2013Meier survival curves with log-rank testing, and group comparisons were performed with parametric or non-parametric tests as appropriate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 45\u2009753 SPC episodes were analysed: 10\u2009531 (23.0%) 24G and 35\u2009222 (77.0%) 26G. Baseline characteristics were comparable between the groups. The mean dwell time was slightly longer for 26G than for 24G (35.1 vs 32.6\u2009hours, p&lt;0.001), although the absolute difference was small. Therapy completion rates were nearly identical (42.6% vs 42.0%, p=0.286). First-attempt success was higher with 26G (79% vs 74%, p&lt;0.001), representing a clinically relevant improvement. The complication profile showed a trade-off: 26G SPCs had fewer leaks (11.9% vs 14.4%, p&lt;0.001) and occlusions (4.0% vs 4.8%,\n                      <jats:italic>p<\/jats:italic>\n                      &lt;0.001), but a slightly higher rate of phlebitis (4.6% vs 4.2%, p&lt;0.001). Severe infiltration and extravasation rates were comparable. Overall complication rates were not significantly different between the groups. In the transfusion subgroup, 26G SPCs were used most frequently, and outcomes were not clinically different from those of 24G, with no excess complications observed, supporting their clinical feasibility for blood administration.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this large neonatal cohort, 26G SPCs were associated with a statistically longer dwell time than 24G SPCs, although the absolute difference was small. Therapy completion and complication rates were comparable between the groups, whereas first-attempt insertion success rates were higher with 26G SPCs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjopen-2026-121488","type":"journal-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T18:05:31Z","timestamp":1784829931000},"page":"e121488","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Comparative performance of 24G and 26G short peripheral catheters in neonates: a single-centre retrospective cohort study in a tertiary neonatal intensive care unit"],"prefix":"10.1136","volume":"16","author":[{"given":"Matheus F P.T","family":"van Rens","sequence":"first","affiliation":[{"name":"Neonatal Intensive Care Unit (NICU), Radboud University Medical Center, Amalia Children\u2019s Hospital, Radboud University, Nijmegen, GE, The Netherlands"},{"name":"Neonatal Intensive Care Unit, Women\u2019s Wellness and Research Center, P. O. Box: 3050, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fiammetta","family":"Piersigilli","sequence":"additional","affiliation":[{"name":"Neonatal Intensive Care Unit, Cliniques Saint Luc, Universit\u00e9 de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2518-8161","authenticated-orcid":false,"given":"Einas E","family":"Elmalik","sequence":"additional","affiliation":[{"name":"Neonatal Intensive Care Unit, Women\u2019s Wellness and Research Center, P. O. Box: 3050, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Airene L V","family":"Francia","sequence":"additional","affiliation":[{"name":"Neonatal Intensive Care Unit, Women\u2019s Wellness and Research Center, P. O. Box: 3050, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3854-6976","authenticated-orcid":false,"given":"Fredericus H J","family":"van Loon","sequence":"additional","affiliation":[{"name":"Anaesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands"},{"name":"Institute of People and Health Sciences, Faculty of PeriOperative Care & Technology, Fontys University of Applied Sciences, Fontys University of Applied Sciences, Eindhoven, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2627-4806","authenticated-orcid":false,"given":"Mohammad A A","family":"Bayoumi","sequence":"additional","affiliation":[{"name":"Neonatal Intensive Care Unit, Women\u2019s Wellness and Research Center, P. O. Box: 3050, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"2026072311051853000_16.7.e121488.1","doi-asserted-by":"publisher","DOI":"10.1053\/S1536-0903(03)00171-1"},{"key":"2026072311051853000_16.7.e121488.2","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2020-047788","article-title":"Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study","volume":"11","author":"van Rens","year":"2021","journal-title":"BMJ Open"},{"key":"2026072311051853000_16.7.e121488.3","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000558"},{"key":"2026072311051853000_16.7.e121488.4","doi-asserted-by":"crossref","DOI":"10.3389\/fped.2022.980725","article-title":"The ABBA project (Assess Better Before Access): A retrospective cohort study of neonatal intravascular device outcomes","volume":"10","author":"van Rens","year":"2022","journal-title":"Front Pediatr"},{"key":"2026072311051853000_16.7.e121488.5","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1177\/11297298241291248","article-title":"The NAVIGATE project: A GloVANet-WoCoVA position statement on the nomenclature for vascular access devices","volume":"26","author":"van Rens","year":"2025","journal-title":"J Vasc Access"},{"key":"2026072311051853000_16.7.e121488.6","unstructured":"Spencer TR . Vascular access \u2013 an evidence-based approach. cvr calc 2.0 \u2013 catheter to vessel ratio. 2025. Available: https:\/\/vascularaccess.com.au\/catheter-vessel-ratio"},{"key":"2026072311051853000_16.7.e121488.7","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000532","article-title":"Infusion Therapy Standards of Practice, 9th Edition","volume":"47","author":"Nickel","year":"2024","journal-title":"J Infus Nurs"},{"key":"2026072311051853000_16.7.e121488.8","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-025-00301-1","article-title":"Short versus long peripheral intravenous catheters in neonates: a retrospective cohort study","volume":"15","author":"van Rens","year":"2025","journal-title":"Sci Rep"},{"key":"2026072311051853000_16.7.e121488.9","unstructured":"Becton D . Pro iv catheter \u2013 product brochure. KMT Medical; 2022. Available: https:\/\/www.kmtmed.com\/wp-content\/uploads\/2022\/06\/BD-Neoflon-Pro-Brochure.pdf"}],"container-title":["BMJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjopen-2026-121488","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T18:05:32Z","timestamp":1784829932000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopen.bmj.com\/lookup\/doi\/10.1136\/bmjopen-2026-121488"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":9,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7,23]]},"published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1136\/bmjopen-2026-121488"],"URL":"https:\/\/doi.org\/10.1136\/bmjopen-2026-121488","relation":{},"ISSN":["2044-6055","2044-6055"],"issn-type":[{"value":"2044-6055","type":"print"},{"value":"2044-6055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]}}}