{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T01:40:56Z","timestamp":1793151656831,"version":"4.5.0"},"reference-count":65,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2023,10,13]]},"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:sec>\n                  <jats:title>Aims<\/jats:title>\n                  <jats:p>This study aims to compare the clinical outcome of Descemet membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) in patients with corneal endothelial dysfunction due to Fuchs\u2019 endothelial dystrophy or pseudophakic bullous keratopathy.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>We conducted a meta-analysis using a literature search of Embase, PubMed, Cochrane CENTRAL, ClinicalTrials.gov and WHO ICTRP databases. We included randomised controlled trials (RCTs) and cohort studies that compared DMEK and UT-DSAEK (graft&lt;130\u2009\u00b5m), with a follow-up of \u226512 months, published until 20 February 2022. We used the Revised Cochrane risk-of-bias tool for RCTs and the Risk of Bias in Non-Randomised Studies-of Interventions system for cohort studies.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Out of 144 records, 8 studies (3 RCTs, 2 fellow-eye studies and 3 cohort studies) were included, encompassing 376 eyes, (N=187\u2009DMEK vs N=189 UT-DSAEK). The 12-month logarithm of the minimum angle of resolution best-corrected visual acuity (BCVA) was better post-DMEK (mean difference \u22120.06 (95% CI \u22120.10 to \u20130.02)), but with higher rebubbling risk: OR 2.76 (95% CI 1.46 to 5.22). Heterogeneity was significant I<jats:sup>2<\/jats:sup>=57%. Findings were consistent when excluding retrospective studies, including only studies with low risk of bias or RCTs only. An analysis of studies with mean DSAEK grafts &lt;70\u2009\u00b5m showed no significant difference in BCVA between the procedures. Publication bias was found in the BCVA analysis (Egger\u2019s test p=0.023).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Post-DMEK BCVA is superior to post-UT-DSAEK when using &lt;130\u2009\u00b5m grafts. DSAEK grafts &lt;70\u2009\u00b5m may not significantly differ from DMEK. The higher risk of rebubbling with DMEK necessitates an appropriate selection of patients.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>PROSPERO registration number<\/jats:title>\n                  <jats:p>CRD42022340805.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/bmjophth-2023-001397","type":"journal-article","created":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T13:40:18Z","timestamp":1698846018000},"page":"e001397","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis"],"prefix":"10.1136","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8077-7749","authenticated-orcid":false,"given":"Tal Corina","family":"Sela","sequence":"first","affiliation":[{"name":"School of Public Health, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moti","family":"Iflah","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khitam","family":"Muhsen","sequence":"additional","affiliation":[{"name":"Department of Epidemiology and Preventive Medicine, School of Public Health, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alon","family":"Zahavi","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel"},{"name":"Ophthalmology Department and Laboratory of Eye Research, Felsenstein Medical Research Center, Rabin Medical Center, Petah Tikva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2023,11,1]]},"reference":[{"key":"2025090109274649000_8.1.e001397.1","doi-asserted-by":"crossref","first-page":"631","DOI":"10.2147\/OPTH.S289359","article-title":"Current perspectives on corneal transplantation","volume":"16","author":"Liu","year":"2022","journal-title":"Clin Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.2","article-title":"Descemet\u2019s membrane endothelial keratoplasty (DMEK) versus Descemet\u2019s stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure","volume":"6","author":"Stuart","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"2025090109274649000_8.1.e001397.3","unstructured":"Weisenthal RW et al . External disease and Cornea. In: Weisenthal RW , Daly MK , de Feritas D , eds. 2020-2021 Basic and clinical science course. San Francisco, CA: American Academy of Ophthalmology, 2020: 411\u201353."},{"key":"2025090109274649000_8.1.e001397.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2020.100904"},{"key":"2025090109274649000_8.1.e001397.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.08.017"},{"key":"2025090109274649000_8.1.e001397.6","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1097\/j.jcrs.0000000000000574","article-title":"Outcomes of corneal transplantation in Europe: report by the European Cornea and Cell Transplantation Registry","volume":"47","author":"Dunker","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"2025090109274649000_8.1.e001397.7","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.ophtha.2018.10.022","article-title":"Corneal edema and opacification preferred practice pattern\u00ae","volume":"126","author":"Farid","year":"2019","journal-title":"Ophthalmology"},{"key":"2025090109274649000_8.1.e001397.8","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/ceo.14089","article-title":"Outcomes of corneal transplantation in Australia, in an era of lamellar keratoplasty","volume":"50","author":"Williams","year":"2022","journal-title":"Clin Exp Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.9","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/ICU.0000000000000575","article-title":"Ultrathin Descemet stripping automated endothelial keratoplasty","volume":"30","author":"Durrani","year":"2019","journal-title":"Curr Opin Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.10","doi-asserted-by":"crossref","first-page":"128","DOI":"10.4103\/ojo.ojo_137_22","article-title":"Ongoing debates in endothelial keratoplasty: DMEK is not the new DSAEK!","volume":"15","author":"Al-Mahrouqi","year":"2022","journal-title":"Oman J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.11","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000071"},{"key":"2025090109274649000_8.1.e001397.12","doi-asserted-by":"publisher","DOI":"10.1177\/1120672118757431"},{"key":"2025090109274649000_8.1.e001397.13","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001999"},{"key":"2025090109274649000_8.1.e001397.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.01.051"},{"key":"2025090109274649000_8.1.e001397.15","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-7753"},{"key":"2025090109274649000_8.1.e001397.16","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001510"},{"key":"2025090109274649000_8.1.e001397.17","doi-asserted-by":"crossref","first-page":"e173","DOI":"10.1097\/ICO.0b013e3182912fd2","article-title":"Preconditioned donor corneal thickness for microthin endothelial keratoplasty","volume":"32","author":"Thomas","year":"2013","journal-title":"Cornea"},{"key":"2025090109274649000_8.1.e001397.18","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.ophtha.2020.03.023","article-title":"The ongoing debate: Descemet membrane endothelial keratoplasty versus ultrathin Descemet stripping automated endothelial Keratoplasty","volume":"127","author":"Busin","year":"2020","journal-title":"Ophthalmology"},{"key":"2025090109274649000_8.1.e001397.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.05.019"},{"key":"2025090109274649000_8.1.e001397.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.02.029"},{"key":"2025090109274649000_8.1.e001397.21","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002601"},{"key":"2025090109274649000_8.1.e001397.22","doi-asserted-by":"crossref","DOI":"10.1186\/s40662-020-00191-6","article-title":"Ultrathin Descemet stripping automated endothelial keratoplasty versus Descemet membrane endothelial keratoplasty: a fellow-eye comparison","volume":"7","author":"Mencucci","year":"2020","journal-title":"Eye Vis (Lond)"},{"key":"2025090109274649000_8.1.e001397.23","doi-asserted-by":"crossref","DOI":"10.3390\/jcm10030419","article-title":"Visual quality and subjective satisfaction in ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) versus Descemet membrane endothelial Keratoplasty (DMEK): a fellow-eye comparison","volume":"10","author":"Torras-Sanvicens","year":"2021","journal-title":"J Clin Med"},{"key":"2025090109274649000_8.1.e001397.24","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001697"},{"key":"2025090109274649000_8.1.e001397.25","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2020-000546","article-title":"Clinical outcomes of pre-loaded ultra-thin DSAEK and pre-loaded DMEK","volume":"5","author":"Romano","year":"2020","journal-title":"BMJ Open Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.26","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.ajo.2022.09.013","article-title":"Systematic review and meta-analysis: outcomes after Descemet membrane endothelial keratoplasty versus ultrathin Descemet stripping automated endothelial keratoplasty","volume":"245","author":"Maier","year":"2023","journal-title":"Am J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.27","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.ajo.2022.11.027","article-title":"Comment on: systematic review and meta-analysis: outcomes after Descemet membrane endothelial keratoplasty versus ultrathin Descemet stripping automated endothelial keratoplasty","volume":"250","author":"Dimtsas","year":"2023","journal-title":"Am J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.28","doi-asserted-by":"crossref","first-page":"3026","DOI":"10.1038\/s41433-023-02467-2","article-title":"Ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) versus Descemet membrane endothelial keratoplasty (DMEK)-a systematic review and meta-analysis","volume":"37","author":"Hurley","year":"2023","journal-title":"Eye"},{"key":"2025090109274649000_8.1.e001397.29","article-title":"Is ultra-thin Descemet stripping automated endothelial keratoplasty a viable alternative to Descemet membrane endothelial keratoplasty? A systematic review and meta-analysis","volume":"15","author":"Singh","year":"2023","journal-title":"Ther Adv Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.30","doi-asserted-by":"publisher","DOI":"10.1097\/PRS.0b013e318219c171"},{"key":"2025090109274649000_8.1.e001397.31","doi-asserted-by":"crossref","unstructured":"Lasserson TJ , Thomas J , Higgins JP , et al . Chapter 1: starting a review. In: Higgins J , Thomas J , Chandler J , eds. Cochrane handbook for systematic reviews of interventions. Cochrane, 2023.","DOI":"10.1002\/9781119536604.ch1"},{"key":"2025090109274649000_8.1.e001397.32","doi-asserted-by":"publisher","DOI":"10.1007\/s10654-019-00576-5"},{"key":"2025090109274649000_8.1.e001397.33","unstructured":"Institute of Medicine . Finding what works in health care: standards for systematic reviews. Washington, DC: National Academies Press (US), 2011."},{"key":"2025090109274649000_8.1.e001397.34","unstructured":"Deeks J , Higgins J , Altman D , et al . Chapter 10: analysing data and undertaking meta-analyses. In: Higgins J , Thomas J , Chandler J , eds. Cochrane handbook for systematic reviews of interventions. Cochrane, 2023."},{"key":"2025090109274649000_8.1.e001397.35","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"2025090109274649000_8.1.e001397.36","unstructured":"Sela TC , Iflah M , Zahavi A , et al . Safety and efficacy of Ultrathin Descemet\u2019s stripping automated endothelial Keratoplasty (UT-DSAEK) versus Descemet membrane endothelial Keratoplasty (DMEK) for patients with corneal endothelial failure \u2013 systematic review and meta-analysis. PROSPERO. 2022; CRD42022340805. Available: https:\/\/www.crd.york.ac.uk\/prospero\/display_record.php?RecordID=340805 [Accessed 20 May 2023]."},{"key":"2025090109274649000_8.1.e001397.37","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.l4898","article-title":"Rob 2: a revised tool for assessing risk of bias in randomised trials","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"key":"2025090109274649000_8.1.e001397.38","doi-asserted-by":"crossref","unstructured":"Sterne JA , Hern\u00e1n MA , Reeves BC , et al . ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ 2016:i4919. doi:10.1136\/bmj.i4919","DOI":"10.1136\/bmj.i4919"},{"key":"2025090109274649000_8.1.e001397.39","doi-asserted-by":"crossref","DOI":"10.3390\/jcm10215119","article-title":"Comparative analysis of corneal parameters in swept-source imaging between DMEK and UT-DSAEK eyes","volume":"10","author":"Machali\u0144ska","year":"2021","journal-title":"J Clin Med"},{"key":"2025090109274649000_8.1.e001397.40","unstructured":"Chamberlain W . Descemet endothelial thickness comparison trial (DETECT) Clinicaltrials.Gov; Nct02373137 . 2015. Available: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02373137"},{"key":"2025090109274649000_8.1.e001397.41","unstructured":"Chamberlain W , Lin CC , Austin A , et al . DETECT manual of operations and procedures Descemets endothelial thickness comparison trial. Available: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02373137 [Accessed 18 May 2023]."},{"key":"2025090109274649000_8.1.e001397.42","unstructured":"Porco T , Chamberlain W , Rose-Nussbaumer J , et al . Descemets endothelial thickness comparison trial statistical analysis plan. Available: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02373137 [Accessed 18 May 2023]."},{"key":"2025090109274649000_8.1.e001397.43","unstructured":"Nuijts R . DMEK versus DSAEK study. Clinicaltrials.Gov; Nct02793310 . 2016. Available: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02793310?term=NCT02793310&draw=2&rank=1 [Accessed 20 Jan 2023]."},{"key":"2025090109274649000_8.1.e001397.44","doi-asserted-by":"crossref","unstructured":"Rajan M . Corneal transplant clinical trial: 2020: ISRCTN10578843. 2020. doi:10.1186\/ISRCTN10578843","DOI":"10.1186\/ISRCTN10578843"},{"key":"2025090109274649000_8.1.e001397.45","unstructured":"Rajan M . Study protocol. Micro thin Descemet\u2019s stripping automated endothelial Keratoplasty (Micro thin-DSAEK) versus Descemets membrane endothelial Keratoplasty (DMEK): a randomized controlled clinical trial of corneal transplant outcomes and visual function. n.d. Available: https:\/\/www.isrctn.com\/ISRCTN10578843"},{"key":"2025090109274649000_8.1.e001397.46","first-page":"1576","article-title":"Preliminary results of a multicenter randomized clinical trial comparing Descemet membrane endothelial keratoplasty (DMEK) with Ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK)","volume":"59","author":"Dickman","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2025090109274649000_8.1.e001397.47","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.10.009"},{"key":"2025090109274649000_8.1.e001397.48","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.ajo.2022.03.022","article-title":"Efficacy of thin and ultrathin Descemet stripping automated endothelial Keratoplasty and influence of graft thickness on postoperative outcomes: systematic review and meta-analysis","volume":"240","author":"B\u00e9al","year":"2022","journal-title":"Am J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.49","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-22223-y","article-title":"A machine learning approach to explore predictors of graft detachment following posterior Lamellar keratoplasty: a nationwide Registry study","volume":"12","author":"Muijzer","year":"2022","journal-title":"Sci Rep"},{"key":"2025090109274649000_8.1.e001397.50","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2011.343"},{"key":"2025090109274649000_8.1.e001397.51","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2017.07.003"},{"key":"2025090109274649000_8.1.e001397.52","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1080\/02713683.2021.1892150","article-title":"Descemet membrane endothelial keratoplasty versus Descemet stripping automated endothelial keratoplasty in complicated vitrectomized eyes","volume":"46","author":"Mimouni","year":"2021","journal-title":"Curr Eye Res"},{"key":"2025090109274649000_8.1.e001397.53","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1007\/s00347-016-0221-0","article-title":"Treatment of corneal endothelial disorders by DMEK and UT-DSAEK. indications, complications, results and follow-up","volume":"113","author":"Bachmann","year":"2016","journal-title":"Ophthalmologe"},{"key":"2025090109274649000_8.1.e001397.54","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1097\/ICO.0000000000001220","article-title":"Clinical outcome of rebubbling for graft detachment after Descemet membrane endothelial Keratoplasty","volume":"36","author":"Gerber-Hollbach","year":"2017","journal-title":"Cornea"},{"key":"2025090109274649000_8.1.e001397.55","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.ajo.2020.06.023","article-title":"Real-world outcomes of DMEK: a prospective Dutch Registry study","volume":"222","author":"Dunker","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.56","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1080\/02713683.2020.1842459","article-title":"Impact of re-bubbling after Descemet membrane endothelial keratoplasty on long-term results","volume":"46","author":"Gundlach","year":"2021","journal-title":"Curr Eye Res"},{"key":"2025090109274649000_8.1.e001397.57","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.04.023"},{"key":"2025090109274649000_8.1.e001397.58","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1097\/ICO.0000000000001554","article-title":"Recovery of corneal clarity after DMEK followed by rebubbling versus uneventful DMEK","volume":"37","author":"Lazaridis","year":"2018","journal-title":"Cornea"},{"key":"2025090109274649000_8.1.e001397.59","doi-asserted-by":"crossref","first-page":"2494","DOI":"10.1038\/s41433-022-02362-2","article-title":"Rebubbling and graft detachment in Descemet membrane endothelial keratoplasty using a standardised protocol","volume":"37","author":"Fu","year":"2023","journal-title":"Eye"},{"key":"2025090109274649000_8.1.e001397.60","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.ajo.2019.06.012","article-title":"Descemet membrane endothelial keratoplasty versus Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty","volume":"207","author":"Woo","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.61","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/j.ophtha.2018.03.050","article-title":"Five-year graft survival of Descemet membrane endothelial keratoplasty (EK) versus Descemet stripping EK and the effect of donor sex matching","volume":"125","author":"Price","year":"2018","journal-title":"Ophthalmology"},{"key":"2025090109274649000_8.1.e001397.62","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1001\/jamaophthalmol.2019.0877","article-title":"Effect of unilateral endothelial keratoplasty on vision-related quality-of-life outcomes in the Descemet endothelial thickness comparison trial (DETECT)","volume":"137","author":"Ang","year":"2019","journal-title":"JAMA Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.63","doi-asserted-by":"crossref","first-page":"e1127","DOI":"10.1111\/aos.14741","article-title":"Quality of vision and vision-related quality of life after Descemet membrane endothelial keratoplasty: a randomized clinical trial","volume":"99","author":"Dunker","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.64","doi-asserted-by":"crossref","DOI":"10.4172\/2155-9570.1000608","article-title":"Survey of experts on current endothelial keratoplasty techniques","volume":"7","author":"Chamberlain","year":"2016","journal-title":"J Clin Exp Ophthalmol"},{"key":"2025090109274649000_8.1.e001397.65","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2019-315180"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2023-001397","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T16:27:57Z","timestamp":1756744077000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2023-001397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":65,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,11,1]]},"published-print":{"date-parts":[[2023,11]]}},"alternative-id":["10.1136\/bmjophth-2023-001397"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2023-001397","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11]]}}}