{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T17:42:17Z","timestamp":1792172537044,"version":"4.4.0"},"reference-count":17,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T00:00:00Z","timestamp":1703721600000},"content-version":"unspecified","delay-in-days":27,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004761","name":"Natural Science Foundation of Hunan Province, China","doi-asserted-by":"crossref","award":["2022JJ40002"],"award-info":[{"award-number":["2022JJ40002"]}],"id":[{"id":"10.13039\/501100004761","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2023,12,19]]},"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To investigate how the mounting location of wearable devices affects the measurement of light intensity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two commercially available wearable devices, HOBO and Clouclip, were used to compare the effects of different mount locations on light intensity measurement. We assessed the consistency of the measurements of the two devices by placing a HOBO and a Clouclip simultaneously in 26 different light environments and measuring the light intensity. To simulate the real-life usage scenarios of the two devices, we had 29 participants wear two HOBOs\u2014one on the wrist and the other on the chest\u2014along with a Clouclip on their spectacles for 1\u2009day; meanwhile, the light intensity was measured and analysed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      When under the same light environments, the light intensity measured by the Clouclip was 1.09 times higher than that by the HOBO, with an additional 82.62 units (r\n                      <jats:sup>2<\/jats:sup>\n                      =1.00, p&lt;0.001). When simulating the real-life scenarios, the mean light intensity at the eye-level position was significantly lower than that at the chest position (189.13\u00b1665.78\u2009lux vs 490.75\u00b11684.29\u2009lux, p&lt;0.001) and the wrist position (189.13\u00b1665.78\u2009lux vs 483.87\u00b11605.50\u2009lux, p&lt;0.001). However, there was no significant difference in light intensity between the wrist and chest positions (483.87\u00b11605.50\u2009lux vs 490.75\u00b11684.29\u2009lux, p=1.00). Using a threshold of 1000\u2009lux for outdoor exposure, the estimated light exposure at the eye-level position was significantly lower than that at the chest position (3.9% vs 7.8%, \u03c7\n                      <jats:sup>2<\/jats:sup>\n                      =266.14, p&lt;0.001) and the wrist position (3.9% vs 7.7%, \u03c7\n                      <jats:sup>2<\/jats:sup>\n                      =254.25, p&lt;0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our findings revealed significant variations in light exposure among the wrist, chest and eye position. Therefore, caution must be exercised when comparing results obtained from different wearable devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2023-001409","type":"journal-article","created":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T12:20:21Z","timestamp":1703766021000},"page":"e001409","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":11,"title":["Effect of mount location on the quantification of light intensity in myopia study"],"prefix":"10.1136","volume":"8","author":[{"given":"Longbo","family":"Wen","sequence":"first","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Liu","sequence":"additional","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhao","family":"Chen","sequence":"additional","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinglin","family":"Xu","sequence":"additional","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziqi","family":"Hu","sequence":"additional","affiliation":[{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3829-7415","authenticated-orcid":false,"given":"Weizhong","family":"Lan","sequence":"additional","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Guangzhou Aier Eye Hospital, Jinan University, Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhikuan","family":"Yang","sequence":"additional","affiliation":[{"name":"Aier School of Ophthalmology, Central South University, Changsha Aier Eye Hospital, Aier Eye Hospital Group, Changsha, China"},{"name":"Hunan Province Optometry Engineering and Technology Research Center, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2023,12,28]]},"reference":[{"key":"2025090109571011000_8.1.e001409.1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-307724"},{"key":"2025090109571011000_8.1.e001409.2","doi-asserted-by":"crossref","DOI":"10.1167\/iovs.62.5.3","article-title":"IMI risk factors for myopia","volume":"62","author":"Morgan","year":"2021","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2025090109571011000_8.1.e001409.3","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1001\/jamapediatrics.2019.0278","article-title":"Outdoor activity protects against childhood myopia-let the sun shine in","volume":"173","author":"Zadnik","year":"2019","journal-title":"JAMA Pediatr"},{"key":"2025090109571011000_8.1.e001409.4","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13403"},{"key":"2025090109571011000_8.1.e001409.5","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/OPX.0000000000001357","article-title":"Effect of outdoor activities in myopia control: meta-analysis of clinical studies","volume":"96","author":"Deng","year":"2019","journal-title":"Optom Vis Sci"},{"key":"2025090109571011000_8.1.e001409.6","doi-asserted-by":"crossref","DOI":"10.3390\/ijerph16142595","article-title":"Dose\u2013response relationship of outdoor exposure and myopia indicators: A systematic review and meta-analysis of various research methods","volume":"16","author":"Ho","year":"2019","journal-title":"Int J Environ Res Public Health"},{"key":"2025090109571011000_8.1.e001409.7","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2009.105"},{"key":"2025090109571011000_8.1.e001409.8","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.173187"},{"key":"2025090109571011000_8.1.e001409.9","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1038\/eye.2012.49","article-title":"Comparison of measurements of time outdoors and light levels as risk factors for myopia in young Singapore children","volume":"26","author":"Dharani","year":"2012","journal-title":"Eye (Lond)"},{"key":"2025090109571011000_8.1.e001409.10","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1097\/OPX.0000000000000160","article-title":"Light exposure and physical activity in myopic and Emmetropic children","volume":"91","author":"Read","year":"2014","journal-title":"Optometry and Vision Science"},{"key":"2025090109571011000_8.1.e001409.11","doi-asserted-by":"crossref","DOI":"10.1167\/tvst.6.3.20","article-title":"Development of the Fitsight fitness Tracker to increase time outdoors to prevent myopia","volume":"6","author":"Verkicharla","year":"2017","journal-title":"Transl Vis Sci Technol"},{"key":"2025090109571011000_8.1.e001409.12","doi-asserted-by":"crossref","first-page":"e1222","DOI":"10.1111\/aos.14785","article-title":"The Clouclip, a Wearable device for measuring near-work and outdoor time: validation and comparison of objective measures with questionnaire estimates","volume":"99","author":"Wen","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"2025090109571011000_8.1.e001409.13","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1111\/opo.12112","article-title":"A cluster randomized controlled trial evaluating an incentive-based outdoor physical activity programme to increase outdoor time and prevent myopia in children","volume":"34","author":"Ngo","year":"2014","journal-title":"Ophthalmic Physiol Opt"},{"key":"2025090109571011000_8.1.e001409.14","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-318918"},{"key":"2025090109571011000_8.1.e001409.15","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.ophtha.2022.06.024","article-title":"Time outdoors in reducing myopia: A school-based cluster randomized trial with objective monitoring of outdoor time and light intensity","volume":"129","author":"He","year":"2022","journal-title":"Ophthalmology"},{"key":"2025090109571011000_8.1.e001409.16","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4689"},{"key":"2025090109571011000_8.1.e001409.17","first-page":"R613","article-title":"Naturalistic studies of human light exposure","volume":"245","author":"Okudaira","year":"1983","journal-title":"Am J Physiol"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2023-001409","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T16:57:19Z","timestamp":1756745839000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2023-001409"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12,28]]},"published-print":{"date-parts":[[2023,12]]}},"alternative-id":["10.1136\/bmjophth-2023-001409"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2023-001409","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}