{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T05:38:15Z","timestamp":1786945095727,"version":"build-2736575974"},"reference-count":32,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T00:00:00Z","timestamp":1712188800000},"content-version":"unspecified","delay-in-days":3,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2024,3,23]]},"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>Preclinical validation study to assess the feasibility and accuracy of electromagnetic image-guided systems (EM-IGS) in orbital surgery using high-fidelity physical orbital anatomy simulators.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>EM-IGS platform, clinical software, navigation instruments and reference system (StealthStation S8, Medtronic) were evaluated in a mock operating theatre at the Royal Victoria Eye and Ear Hospital, a tertiary academic hospital in Dublin, Ireland. Five high-resolution 3D-printed model skulls were created using CT scans of five anonymised patients with an orbital tumour that previously had a successful orbital biopsy or excision. The ability of ophthalmic surgeons to achieve satisfactory system registration in each model was assessed. Subsequently, navigational accuracy was recorded using defined anatomical landmarks as ground truth. Qualitative feedback on the system was also attained.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Three independent surgeons participated in the study, one junior trainee, one fellow and one consultant. Across models, more senior participants were able to achieve a smaller system-generated registration error in a fewer number of attempts. When assessing navigational accuracy, submillimetre accuracy was achieved for the majority of points (16 landmarks per model, per participant). Qualitative surgeon feedback suggested acceptability of the technology, although interference from mobile phones near the operative field was noted.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>This study suggests the feasibility and accuracy of EM-IGS in a preclinical validation study for orbital surgery using patient specific 3D-printed skulls. This preclinical study provides the foundation for clinical studies to explore the safety and effectiveness of this technology.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/bmjophth-2023-001568","type":"journal-article","created":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T13:40:41Z","timestamp":1712238041000},"page":"e001568","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Image-guided orbital surgery: a preclinical validation study using a high-resolution physical model"],"prefix":"10.1136","volume":"9","author":[{"given":"Rizwana I","family":"Khan","sequence":"first","affiliation":[{"name":"Royal Victoria Eye and Ear Hospital, Dublin, Ireland"},{"name":"RCSI University of Medicine and Health Sciences, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3626-8677","authenticated-orcid":false,"given":"Kealan","family":"McElhinney","sequence":"additional","affiliation":[{"name":"Royal Victoria Eye and Ear Hospital, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Dickson","sequence":"additional","affiliation":[{"name":"School of Mechanical & Materials Engineering, University College Dublin, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronan P","family":"Kileen","sequence":"additional","affiliation":[{"name":"Department of Radiology, St Vincent\u2019s University Hospital, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2171-0418","authenticated-orcid":false,"given":"Conor","family":"Murphy","sequence":"additional","affiliation":[{"name":"Royal Victoria Eye and Ear Hospital, Dublin, Ireland"},{"name":"RCSI University of Medicine and Health Sciences, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donncha F","family":"O\u2019Brien","sequence":"additional","affiliation":[{"name":"RCSI University of Medicine and Health Sciences, Dublin, Ireland"},{"name":"Department of Neurosurgery, Beaumont Hospital, Dublin, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2024,4,4]]},"reference":[{"key":"2025090110133085000_9.1.e001568.1","doi-asserted-by":"crossref","unstructured":"Rootman J , Stewart B , Goldberg RA . Orbital surgery: a conceptual approach. 1995. doi:10.1097\/00002341-199603000-00052","DOI":"10.1097\/00002341-199603000-00052"},{"key":"2025090110133085000_9.1.e001568.2","unstructured":"Rootman J . Diseases of the orbit: a multidisciplinary approach. 1988."},{"key":"2025090110133085000_9.1.e001568.3","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1979.51.2.0219"},{"key":"2025090110133085000_9.1.e001568.4","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1016\/j.ophtha.2018.01.030","article-title":"Incidence, risk factors, and management of blindness after orbital surgery","volume":"125","author":"Jacobs","year":"2018","journal-title":"Ophthalmology"},{"key":"2025090110133085000_9.1.e001568.5","doi-asserted-by":"crossref","first-page":"359","DOI":"10.3109\/01676830.2014.915329","article-title":"The anatomical location and laterality of orbital cavernous haemangiomas","volume":"33","author":"McNab","year":"2014","journal-title":"Orbit"},{"key":"2025090110133085000_9.1.e001568.6","doi-asserted-by":"publisher","DOI":"10.1097\/00002341-199206000-00002"},{"key":"2025090110133085000_9.1.e001568.7","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1038\/sj.eye.6702376","article-title":"Update on orbital anatomy","volume":"20","author":"Ren\u00e9","year":"2006","journal-title":"Eye (Lond)"},{"key":"2025090110133085000_9.1.e001568.8","doi-asserted-by":"crossref","first-page":"107","DOI":"10.17116\/neiro2016806107-114","article-title":"Navigation systems in neurosurgery","volume":"80","author":"Shurkhay","year":"2016","journal-title":"Zh Vopr Neirokhir Im N N Burdenko"},{"key":"2025090110133085000_9.1.e001568.9","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/00002341-200111000-00012","article-title":"The use of a computer-assisted image-guided system (Instatrak) in orbital surgery","volume":"17","author":"Camara","year":"2001","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"2025090110133085000_9.1.e001568.10","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/IIO.0000000000000188","article-title":"Innovations in orbital surgical navigation, orbital implants, and orbital surgical training","volume":"57","author":"Grob","year":"2017","journal-title":"Int Ophthalmol Clin"},{"key":"2025090110133085000_9.1.e001568.11","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s00381-019-04390-y","article-title":"Frameless stereotaxy: it is all about precision","volume":"36","author":"Atteya","year":"2020","journal-title":"Childs Nerv Syst"},{"key":"2025090110133085000_9.1.e001568.12","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-021-89897-8","article-title":"Virtual splint registration for electromagnetic and optical navigation in orbital and craniofacial surgery","volume":"11","author":"Schreurs","year":"2021","journal-title":"Sci Rep"},{"key":"2025090110133085000_9.1.e001568.13","doi-asserted-by":"crossref","first-page":"995","DOI":"10.4103\/ijo.IJO_807_18","article-title":"Computer-assisted navigation in orbitofacial surgery","volume":"67","author":"Udhay","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"2025090110133085000_9.1.e001568.14","doi-asserted-by":"publisher","DOI":"10.1007\/s007010170023"},{"key":"2025090110133085000_9.1.e001568.15","first-page":"353","article-title":"Intraoperative cranial navigation","volume":"43","author":"Maciunas","year":"1996","journal-title":"Clin Neurosurg"},{"key":"2025090110133085000_9.1.e001568.16","doi-asserted-by":"publisher","DOI":"10.1146\/annurev-bioeng-070909-105249"},{"key":"2025090110133085000_9.1.e001568.17","doi-asserted-by":"crossref","first-page":"435","DOI":"10.4103\/0974-9233.164613","article-title":"Novel surgical approaches to the orbit","volume":"22","author":"Campbell","year":"2015","journal-title":"Middle East Afr J Ophthalmol"},{"key":"2025090110133085000_9.1.e001568.18","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1017\/S0022215119001567","article-title":"Use of an image-guided navigation system for routine endonasal endoscopic dacryocystorhinostomy","volume":"133","author":"Reichel","year":"2019","journal-title":"J Laryngol Otol"},{"key":"2025090110133085000_9.1.e001568.19","doi-asserted-by":"publisher","DOI":"10.1177\/0003489416667742"},{"key":"2025090110133085000_9.1.e001568.20","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.1017\/S0022215115001346","article-title":"Face and content validation of a novel three-dimensional printed temporal bone for surgical skills development","volume":"129 Suppl 3","author":"Da Cruz","year":"2015","journal-title":"J Laryngol Otol"},{"key":"2025090110133085000_9.1.e001568.21","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/j.wneu.2016.03.095","article-title":"Three-dimensional printed modeling of an arteriovenous malformation including blood flow","volume":"90","author":"Thawani","year":"2016","journal-title":"World Neurosurg"},{"key":"2025090110133085000_9.1.e001568.22","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1007\/s00464-015-4185-y","article-title":"From CT scanning to 3-D printing technology for the preoperative planning in laparoscopic splenectomy","volume":"30","author":"Pietrabissa","year":"2016","journal-title":"Surg Endosc"},{"key":"2025090110133085000_9.1.e001568.23","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1097\/SCS.0000000000002656","article-title":"Cranioplasty enhanced by three-dimensional printing: custom-made three-dimensional-printed titanium implants for skull defects","volume":"27","author":"Park","year":"2016","journal-title":"J Craniofac Surg"},{"key":"2025090110133085000_9.1.e001568.24","doi-asserted-by":"crossref","first-page":"e142","DOI":"10.1016\/j.wneu.2018.07.236","article-title":"Using three-dimensional printing to create individualized cranial nerve models for skull base tumor surgery","volume":"120","author":"Lin","year":"2018","journal-title":"World Neurosurgery"},{"key":"2025090110133085000_9.1.e001568.25","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.2147\/OPTH.S119055","article-title":"Interactive navigation-guided ophthalmic plastic surgery: navigation enabling of telescopes and their use in endoscopic lacrimal surgeries","volume":"10","author":"Ali","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"2025090110133085000_9.1.e001568.26","doi-asserted-by":"publisher","DOI":"10.1076\/orbi.21.3.199.7180"},{"key":"2025090110133085000_9.1.e001568.27","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1080\/01676830.2018.1490440","article-title":"Perceptions and use of computer-assisted surgery (CAS) in the orbit","volume":"38","author":"Hussain","year":"2019","journal-title":"Orbit"},{"key":"2025090110133085000_9.1.e001568.28","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s10143-005-0007-3","article-title":"Frameless image-guided neuronavigation in orbital surgery: practical applications","volume":"29","author":"Hejazi","year":"2006","journal-title":"Neurosurg Rev"},{"key":"2025090110133085000_9.1.e001568.29","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.3171\/2015.5.JNS15330","article-title":"Orbit-associated tumors: navigation and control of resection using intraoperative computed tomography","volume":"124","author":"Terpolilli","year":"2016","journal-title":"J Neurosurg"},{"key":"2025090110133085000_9.1.e001568.30","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1177\/112067210601600314","article-title":"Computer-assisted image-guided orbit surgery","volume":"16","author":"Karcioglu","year":"2006","journal-title":"Eur J Ophthalmol"},{"key":"2025090110133085000_9.1.e001568.31","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1159\/000097922","article-title":"Application accuracy of an electromagnetic field-based image-guided navigation system","volume":"85","author":"Rosenow","year":"2007","journal-title":"Stereotact Funct Neurosurg"},{"key":"2025090110133085000_9.1.e001568.32","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(09)61116-8"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2023-001568","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T17:13:43Z","timestamp":1756746823000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2023-001568"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,4,4]]},"published-print":{"date-parts":[[2024,4]]}},"alternative-id":["10.1136\/bmjophth-2023-001568"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2023-001568","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4]]}}}