{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T16:45:04Z","timestamp":1774975504876,"version":"3.50.1"},"reference-count":20,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T00:00:00Z","timestamp":1726444800000},"content-version":"unspecified","delay-in-days":15,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2024,9,3]]},"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n                  <jats:title>Purpose<\/jats:title>\n                  <jats:p>To compare the two most used digital alignment systems regarding precision, repeatability and loss of track.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>15 eyes of 15 patients older than 21 years with cataracts were included in this prospective study. The two systems were intraoperatively superimposed and recorded, and the alignment of the two displayed alignment axes was analysed regarding precision, repeatability and loss of track.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>There was a significant difference in precision and repeatability between the two digital alignment systems regarding the projected alignment axis. The deviation from the actual target axis was significantly different, with a mean of 0.34\u00b0\u00b10.75\u00b0 for the Zeiss system and 1.60\u00b0\u00b11.08\u00b0 for the Alcon system (p=0.03, n=14). The within-subject SD was significantly lower with 0.21\u00b0 for the Zeiss system and 0.34\u00b0 for the Alcon system (p=0.03, n=14).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>The Zeiss Callisto system showed a significantly lower deviation from the target axis, higher stability with eye movements and less need for microscope illumination than the Alcon system. Both systems showed high precision when compared with manual marking methods.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Trial registration number<\/jats:title>\n                  <jats:p>\n                     <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"clintrialgov\" xlink:href=\"NCT05220683\">NCT05220683<\/jats:ext-link>.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/bmjophth-2024-001875","type":"journal-article","created":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T13:55:39Z","timestamp":1726494939000},"page":"e001875","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of two digital alignment systems for toric intraocular lens implantation"],"prefix":"10.1136","volume":"9","clinical-trial-number":[{"clinical-trial-number":"nct05220683","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct05220683","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8735-0342","authenticated-orcid":false,"given":"Johannes","family":"Zeilinger","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Schlatter","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel","family":"Ruiss","sequence":"additional","affiliation":[{"name":"Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Natascha","family":"Bayer","sequence":"additional","affiliation":[{"name":"Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Kronschl\u00e4ger","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Findl","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2024,9,16]]},"reference":[{"key":"2025090109195971000_9.1.e001875.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.02.025"},{"key":"2025090109195971000_9.1.e001875.2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.122.4.495"},{"key":"2025090109195971000_9.1.e001875.3","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-016-0201-z"},{"key":"2025090109195971000_9.1.e001875.4","doi-asserted-by":"publisher","DOI":"10.1007\/s10654-015-0010-0"},{"key":"2025090109195971000_9.1.e001875.5","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1038\/eye.2015.274","article-title":"Relationship between age, corneal astigmatism, and ocular dimensions with reference to astigmatism in eyes undergoing routine cataract surgery","volume":"30","author":"Collier Wakefield","year":"2016","journal-title":"Eye (Lond)"},{"key":"2025090109195971000_9.1.e001875.6","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1001\/jamaophthalmol.2014.3602","article-title":"Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial","volume":"132","author":"Visser","year":"2014","journal-title":"JAMA Ophthalmol"},{"key":"2025090109195971000_9.1.e001875.7","doi-asserted-by":"crossref","first-page":"646","DOI":"10.3928\/1081597X-20200729-03","article-title":"Sources of Error in Toric Intraocular Lens Power Calculation","volume":"36","author":"Hirnschall","year":"2020","journal-title":"J Refract Surg"},{"key":"2025090109195971000_9.1.e001875.8","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation","volume":"34","author":"Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"2025090109195971000_9.1.e001875.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.024"},{"key":"2025090109195971000_9.1.e001875.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.07.039"},{"key":"2025090109195971000_9.1.e001875.11","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1097\/j.jcrs.0000000000000688","article-title":"Time-efficiency assessment of guided toric intraocular lens cataract surgery: pilot study","volume":"47","author":"Barber\u00e1-Loustaunau","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"2025090109195971000_9.1.e001875.12","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20101005-01"},{"key":"2025090109195971000_9.1.e001875.13","first-page":"135","article-title":"Image-guided lens extraction surgery: a systematic review","volume":"12","author":"Panagiotopoulou","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"2025090109195971000_9.1.e001875.14","doi-asserted-by":"crossref","first-page":"482","DOI":"10.3928\/1081597X-20170504-02","article-title":"Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies","volume":"33","author":"Hura","year":"2017","journal-title":"J Refract Surg"},{"key":"2025090109195971000_9.1.e001875.15","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","article-title":"Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery","volume":"43","author":"Webers","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"2025090109195971000_9.1.e001875.16","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1016\/j.jcrs.2019.03.030","article-title":"Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking","volume":"45","author":"Zhou","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"2025090109195971000_9.1.e001875.17","doi-asserted-by":"crossref","DOI":"10.1186\/s12886-022-02548-y","article-title":"Digital versus slit-beam marking for toric intraocular lenses in cataract surgery","volume":"22","author":"Ding","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"2025090109195971000_9.1.e001875.18","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","article-title":"Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation","volume":"43","author":"Mayer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"2025090109195971000_9.1.e001875.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.04.009"},{"key":"2025090109195971000_9.1.e001875.20","doi-asserted-by":"crossref","first-page":"3020","DOI":"10.4103\/ijo.IJO_465_20","article-title":"Randomized trial comparing visual outcomes of toric intraocular lens implantation using manual and digital marker","volume":"68","author":"Kodavoor","year":"2020","journal-title":"Indian J Ophthalmol"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2024-001875","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T16:20:10Z","timestamp":1756743610000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2024-001875"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,9,16]]},"published-print":{"date-parts":[[2024,9]]}},"alternative-id":["10.1136\/bmjophth-2024-001875"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2024-001875","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9]]}}}