{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:09:25Z","timestamp":1780445365419,"version":"3.54.1"},"reference-count":25,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T00:00:00Z","timestamp":1739404800000},"content-version":"unspecified","delay-in-days":12,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2025,1,31]]},"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Different aqueous restrictive manoeuvres in non-valved devices affect intraocular pressure (IOP) levels in the first postoperative month. This study compares tube ligature (TL) alone to TL plus rip cord stent (TLS) on the efficacy of the Baerveldt 350.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a retrospective consecutive case-series observational study to assess efficacy by measuring IOP, success rates and the reduction of antiglaucoma medication usage over 3 years.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The study included 43 eyes in the TL group and 29 in the TLS group. Initial IOPs were 26.67\u2009mm Hg for TL and 28.21\u2009mm Hg for TLS. After 1 year, IOP decreased to 13.03\u2009mm Hg and 12.11\u2009mm Hg, respectively. Over 3 years, TLS consistently achieved greater reductions in IOP compared with TL, with significant differences of 3.56\u2009mm Hg in the second year (p=0.01) and 3.34\u2009mm Hg in the third year (p=0.01). Mean antiglaucoma medication use decreased from 3.03 (SD 1.29) to 0.72 (SD 0.47) over 3 years, representing a 76.24% reduction, with no differences between the TL and TLS groups. Failure rate at 1 year was significantly lower for TLS under the success criteria of IOP=(6\u201318) mm Hg (TL: 33.33%, TLS: 7.14%, p=0.02). Rates of transient hypotension and hypertensive phase were higher in the TL group: 93.02% vs 34.48% (p&lt;0.001) and 58.14% vs 32.14% (\u03c7\u00b2=4.59, p=0.03), respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Adding the rip cord stent to the Baerveldt implant significantly enhances long-term IOP control and reduces failure rates compared with TL alone. The lower incidence of hypertensive phases could be due to sequential tube opening. Small sample size, lack of randomisation and follow-up discrepancies may introduce bias and limit statistical power, highlighting the need for further research to confirm these conclusions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2024-001879","type":"journal-article","created":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T13:05:18Z","timestamp":1739451918000},"page":"e001879","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Impact of the restrictive technique on outcomes in Baerveldt-350 implant surgery"],"prefix":"10.1136","volume":"10","author":[{"given":"Gloria","family":"Segura-Duch","sequence":"first","affiliation":[{"name":"Ophthalmology, Verte-ICO Oftalmolog\u00eda, Barcelona, Spain"},{"name":"Oftalmology, Centro de Oftalmolog\u00eda Barraquer, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Oliver-Gutierrez","sequence":"additional","affiliation":[{"name":"Ophthalmology, Verte-ICO Oftalmolog\u00eda, Barcelona, Spain"},{"name":"Ophthalmology, Hospital del Valle Hebr\u00f3n, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5965-8315","authenticated-orcid":false,"given":"Susana","family":"Duch","sequence":"additional","affiliation":[{"name":"Ophthalmology, Verte-ICO Oftalmolog\u00eda, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mar","family":"Schilt","sequence":"additional","affiliation":[{"name":"Ophthalmology, Verte-ICO Oftalmolog\u00eda, Barcelona, Spain"},{"name":"Ophtalmology, Hospital Municipal de Badalona, Badalona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Arciniegas-Perasso","sequence":"additional","affiliation":[{"name":"Ophthalmology, Verte-ICO Oftalmolog\u00eda, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,2,13]]},"reference":[{"key":"2026010721202020000_10.1.e001879.1","first-page":"368","article-title":"Experimental studies of aqueous filtration using the Molteno implant","volume":"85","author":"Minckler","year":"1987","journal-title":"Trans Am Ophthalmol Soc"},{"key":"2026010721202020000_10.1.e001879.2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00803-0"},{"key":"2026010721202020000_10.1.e001879.3","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0988"},{"key":"2026010721202020000_10.1.e001879.4","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-1424"},{"key":"2026010721202020000_10.1.e001879.5","first-page":"370","article-title":"Elevated levels of transforming growth factor beta and prostaglandin E2 in aqueous humor from patients undergoing filtration surgery for glaucoma","volume":"43","author":"Freedman","year":"2008","journal-title":"Can J Ophthalmol"},{"key":"2026010721202020000_10.1.e001879.6","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12274"},{"key":"2026010721202020000_10.1.e001879.7","doi-asserted-by":"publisher","DOI":"10.1159\/000101925"},{"key":"2026010721202020000_10.1.e001879.8","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)91223-4"},{"key":"2026010721202020000_10.1.e001879.9","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.1986.tb00470.x"},{"key":"2026010721202020000_10.1.e001879.10","first-page":"444","article-title":"Single stage Molteno implant with combination internal occlusion and external ligature","volume":"21","author":"Latina","year":"1990","journal-title":"Ophthalmic Surg"},{"key":"2026010721202020000_10.1.e001879.11","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1007\/s10792-017-0654-8","article-title":"Hypertensive phase and its association with surgical outcomes in Baerveldt implantation","volume":"38","author":"Chansangpetch","year":"2018","journal-title":"Int Ophthalmol"},{"key":"2026010721202020000_10.1.e001879.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.01.003"},{"key":"2026010721202020000_10.1.e001879.13","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000001969"},{"key":"2026010721202020000_10.1.e001879.14","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00574-8"},{"key":"2026010721202020000_10.1.e001879.15","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(03)00630-5"},{"key":"2026010721202020000_10.1.e001879.16","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1016\/j.ogla.2020.05.001","article-title":"Treatment Outcomes Using the PAUL Glaucoma Implant to Control Intraocular Pressure in Eyes with Refractory Glaucoma","volume":"3","author":"Koh","year":"2020","journal-title":"Ophthalmol Glaucoma"},{"key":"2026010721202020000_10.1.e001879.17","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1097\/00061198-199808000-00005","article-title":"The effect of mitomycin C on Molteno implant surgery: a 1-year randomized, masked, prospective study","volume":"7","author":"Cantor","year":"1998","journal-title":"J Glaucoma"},{"key":"2026010721202020000_10.1.e001879.18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.09.037"},{"key":"2026010721202020000_10.1.e001879.19","doi-asserted-by":"publisher","DOI":"10.1046\/j.1442-9071.2003.00644.x"},{"key":"2026010721202020000_10.1.e001879.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.04.008"},{"key":"2026010721202020000_10.1.e001879.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.05.004"},{"key":"2026010721202020000_10.1.e001879.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.04.018"},{"key":"2026010721202020000_10.1.e001879.23","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.2147\/OPTH.S246905","article-title":"Comparison of Two Tube-Modification Techniques in Baerveldt Glaucoma Implantation in Refractory Glaucoma","volume":"14","author":"Petpiroon","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"2026010721202020000_10.1.e001879.24","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/IJG.0b013e3182447b7c","article-title":"Surgical outcomes of the Baerveldt Glaucoma Implant: differences between surgical techniques in the Rotterdam Eye Hospital","volume":"22","author":"Poels","year":"2013","journal-title":"J Glaucoma"},{"key":"2026010721202020000_10.1.e001879.25","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.116.5.571"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2024-001879","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T05:20:44Z","timestamp":1767849644000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2024-001879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,2,13]]},"published-print":{"date-parts":[[2025,2]]}},"alternative-id":["10.1136\/bmjophth-2024-001879"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2024-001879","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2]]}}}