{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T16:55:12Z","timestamp":1791910512862,"version":"4.3.4"},"reference-count":33,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,1,11]],"date-time":"2025-01-11T00:00:00Z","timestamp":1736553600000},"content-version":"unspecified","delay-in-days":10,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2024,11,20]]},"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To quantify the effect of cataract surgery on cornea shape.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Patients undergoing cataract surgery with standardised 2.75\u2009mm surgical incisions at 110 degrees with a side port at 50 degrees were included. Repeat biometric measurements were taken before surgery and at 6\u2009weeks on both operated and unoperated fellow eyes. Data were transformed into Long\u2019s formalism for analysis. Device-specific measurement error was determined. The main outcome measure was the change in keratometry taking into account the change in keratometry of the unoperated fellow eye. Secondary outcome measures included the variability introduced due to location of the incision.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>132 patients were included. The mean change in keratometry of the operated eye was \u22120.23@111\/+0.21@21 (95% CI \u22121.43@122\/+0.04@32 to +1.04@135\/+0.30@45). The flattening effect of the surgical incision was greater and more variable than the steepening effect (p&lt;0.01), particularly if the incision was in the flat meridian. Coupling, defined as ratio of the keratometric change in the preoperative meridians of K2 and K1, varied from 0.91 (SD 2.31) for eyes with an incision in the steep meridian, 0.75 (SD 1.81) for an incision in the flat meridian to 0.28 (SD 2.06) when the incision was made in a neutral meridian.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Cataract surgery has a slightly greater flattening than steepening effect on corneal shape. Although the effects are very small and variable with incomplete coupling, it is preferable to place the incision in the steep meridian. Greater emphasis, however, should be placed on eye-specific factors, such as biometry, or patient-related factors to optimise refractive outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2024-001920","type":"journal-article","created":{"date-parts":[[2025,1,11]],"date-time":"2025-01-11T23:50:19Z","timestamp":1736639419000},"page":"e001920","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Cataract surgery has minimal effect on corneal shape"],"prefix":"10.1136","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0957-3222","authenticated-orcid":false,"given":"Fadi","family":"Alfaqawi","sequence":"first","affiliation":[{"name":"Royal Liverpool University Hospital, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8534-6817","authenticated-orcid":false,"given":"Luca","family":"Pagano","sequence":"additional","affiliation":[{"name":"Ophthalmology, Royal Liverpool and Broadgreen Hospitals NHS Trust, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esmaeil M","family":"Arbabi","sequence":"additional","affiliation":[{"name":"Royal Liverpool University Hospital, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5148-7643","authenticated-orcid":false,"given":"Vito","family":"Romano","sequence":"additional","affiliation":[{"name":"Eye Unit, Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Al-Maskari","sequence":"additional","affiliation":[{"name":"Royal Liverpool University Hospital, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8907-1176","authenticated-orcid":false,"given":"Keri","family":"McLean","sequence":"additional","affiliation":[{"name":"Royal Liverpool University Hospital St Paul\u2019s Eye Unit, Liverpool, UK"},{"name":"Department of Eye and Vision Science, University of Liverpool, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriella","family":"Czanner","sequence":"additional","affiliation":[{"name":"Liverpool John Moores University, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0390-0592","authenticated-orcid":false,"given":"Stephen B","family":"Kaye","sequence":"additional","affiliation":[{"name":"Department of Eye and Vision Science, University of Liverpool, Liverpool, UK"},{"name":"Ophthalmology, Royal Liverpool University Hospital, Liverpool, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,1,11]]},"reference":[{"key":"2026010721200951000_10.1.e001920.1","doi-asserted-by":"publisher","DOI":"10.1093\/shm\/13.2.307"},{"key":"2026010721200951000_10.1.e001920.2","first-page":"509","article-title":"Systematic review of population-based studies of the prevalence of cataracts","volume":"81","author":"Acosta","year":"2006","journal-title":"Arch Soc Esp Oftalmol"},{"key":"2026010721200951000_10.1.e001920.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00492-9"},{"key":"2026010721200951000_10.1.e001920.4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2009.02117.x"},{"key":"2026010721200951000_10.1.e001920.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.11.013"},{"key":"2026010721200951000_10.1.e001920.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfma.2011.03.002"},{"key":"2026010721200951000_10.1.e001920.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.11.004"},{"key":"2026010721200951000_10.1.e001920.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.07.009"},{"key":"2026010721200951000_10.1.e001920.9","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-320231"},{"key":"2026010721200951000_10.1.e001920.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.12.064"},{"key":"2026010721200951000_10.1.e001920.11","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/3257217","article-title":"Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens","volume":"2016","author":"Lubi\u0144ski","year":"2016","journal-title":"J Ophthalmol"},{"key":"2026010721200951000_10.1.e001920.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2003.10.010"},{"key":"2026010721200951000_10.1.e001920.13","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00605-2"},{"key":"2026010721200951000_10.1.e001920.14","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80075-8"},{"key":"2026010721200951000_10.1.e001920.15","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00796-3"},{"key":"2026010721200951000_10.1.e001920.16","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199706000-00032"},{"key":"2026010721200951000_10.1.e001920.17","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2013.266"},{"key":"2026010721200951000_10.1.e001920.18","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01639-5"},{"key":"2026010721200951000_10.1.e001920.19","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1990.tb00883.x"},{"key":"2026010721200951000_10.1.e001920.20","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2022-001015","article-title":"Standardised approach to the reporting and presentation of refractive data: electronic patient record","volume":"7","author":"Kaye","year":"2022","journal-title":"BMJ Open Ophthalmol"},{"key":"2026010721200951000_10.1.e001920.21","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197601000-00005"},{"key":"2026010721200951000_10.1.e001920.22","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1983.tb00599.x"},{"key":"2026010721200951000_10.1.e001920.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.09.010"},{"key":"2026010721200951000_10.1.e001920.24","doi-asserted-by":"publisher","DOI":"10.1007\/s00717-021-00488-4"},{"key":"2026010721200951000_10.1.e001920.25","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(96)30712-4"},{"key":"2026010721200951000_10.1.e001920.26","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80176-9"},{"key":"2026010721200951000_10.1.e001920.27","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00132-7"},{"key":"2026010721200951000_10.1.e001920.28","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13003"},{"key":"2026010721200951000_10.1.e001920.29","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2007.21.1.1"},{"key":"2026010721200951000_10.1.e001920.30","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020101-11"},{"key":"2026010721200951000_10.1.e001920.31","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_882_21"},{"key":"2026010721200951000_10.1.e001920.32","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80146-5"},{"key":"2026010721200951000_10.1.e001920.33","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318278fc44"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2024-001920","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T05:20:21Z","timestamp":1767849621000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2024-001920"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,1,11]]},"published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1136\/bmjophth-2024-001920"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2024-001920","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]}}}