{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:30:46Z","timestamp":1793197846129,"version":"4.5.0"},"reference-count":18,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T00:00:00Z","timestamp":1746662400000},"content-version":"unspecified","delay-in-days":7,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2025,4,22]]},"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To assess the interchangeability of minimum linear diameter (MLD) macular hole (MH) size measurements in high-density horizontal and radial scan modes in optical coherence tomography (OCT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>60 patients with a MH had repeat high-density OCT volume scans in a horizontal (30\u2009\u00b5m interscan-spacing) and a radial (angular 3.75\u00b0 interscan-spacing) mode, and the MLD was measured by five raters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There were no significant differences in the MLD measurements within the horizontal and the radial modes across repeat measurements of each rater in volume scan 1 (all p\u22650.14\u2009and p\u22650.28, respectively), between volume scans 1 and 2 (all p\u22650.14\u2009and p\u22650.69), among the raters (p=0.70\u2009and p=0.60), and using all MLD measurements obtained in this study between primary and repeat measurements in volume scan 1 (p=0.10\u2009and p=0.74) and between measurements obtained in volume scan 1 and 2 (p=0.21\u2009and p=0.90).<\/jats:p>\n                    <jats:p>There was a statistically significant difference of \u221210.05\u2009\u00b5m between the mean MLD of all measurements in the horizontal (n=900) and in the radial (n=900) mode (427.91 (\u00b1187.01) vs 437.97 (\u00b1184.93) \u00b5m; p&lt;0.001). However, the variability of these differences around the mean MLD was large (95% limits of agreement \u221277.31 to 57.21\u2009\u00b5m). The mean difference between all horizontal and all radial MLD measurements in a MH was for MHs that had their widest MLD within 15\u00b0 of the horizontal, vertical and diagonal meridians 0.77 (\u00b113.88) \u00b5m, \u221234.43 (\u00b155.22) \u00b5m and \u221210.39 (\u00b1 34.62) \u00b5m, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Horizontal scans systematically underestimate the maximum MLD if located vertically or diagonally; however, they have less intra-rater and inter-rater and inter-scan variability in MLD measurements as compared with radial scans. Therefore, the two scan modes are not interchangeable but rather complement each other. These results may be limited to the MLD range analysed (125\u2013924\u2009\u00b5m).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2024-002131","type":"journal-article","created":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T01:35:11Z","timestamp":1746754511000},"page":"e002131","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Analysing the translatability of macular hole size measurements between high-density horizontal and radial OCT scan patterns"],"prefix":"10.1136","volume":"10","author":[{"given":"Navid","family":"Johannigmann-Malek","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonard","family":"Coulibaly","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sofia","family":"Groselli","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharina","family":"Gabka","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Charbel Issa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8662-0582","authenticated-orcid":false,"given":"Carmen","family":"Baumann","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, TUM University Hospital, Technical University of Munich (TUM), School of Medicine and Health, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,5,8]]},"reference":[{"key":"2026010721203847000_10.1.e002131.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.07.042"},{"key":"2026010721203847000_10.1.e002131.2","doi-asserted-by":"crossref","first-page":"419","DOI":"10.4103\/jovr.jovr_146_17","article-title":"Pneumatic vitreolysis for management of symptomatic focal vitreomacular traction","volume":"12","author":"Chan","year":"2017","journal-title":"J Ophthalmic Vis Res"},{"key":"2026010721203847000_10.1.e002131.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.07.045"},{"key":"2026010721203847000_10.1.e002131.4","doi-asserted-by":"crossref","DOI":"10.1186\/s40942-023-00472-x","article-title":"Pneumatic vitreolysis versus vitrectomy for the treatment of vitreomacular traction syndrome and macular holes: complication analysis and systematic review with meta-analysis of functional outcomes","volume":"9","author":"Quiroz-Reyes","year":"2023","journal-title":"Int J Retina Vitreous"},{"key":"2026010721203847000_10.1.e002131.5","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1097\/IAE.0000000000001985","article-title":"INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP TECHNIQUE FOR TREATMENT OF FULL-THICKNESS MACULAR HOLES","volume":"38","author":"Rizzo","year":"2018","journal-title":"Retina (Philadelphia, Pa)"},{"key":"2026010721203847000_10.1.e002131.6","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.153189"},{"key":"2026010721203847000_10.1.e002131.7","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1007\/s00417-013-2477-2","article-title":"Idiopathic macular hole: analysis of visual outcomes and the use of indocyanine green or brilliant blue for internal limiting membrane peel","volume":"252","author":"Williamson","year":"2014","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"2026010721203847000_10.1.e002131.8","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.091777"},{"key":"2026010721203847000_10.1.e002131.9","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1038\/eye.2017.254","article-title":"Measurement of full-thickness macular hole size using en face optical coherence tomography","volume":"32","author":"Philippakis","year":"2018","journal-title":"Eye (Lond)"},{"key":"2026010721203847000_10.1.e002131.10","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2019-000404","article-title":"Macular hole morphology and measurement using an automated three-dimensional image segmentation algorithm","volume":"5","author":"Chen","year":"2020","journal-title":"BMJ Open Ophthalmol"},{"key":"2026010721203847000_10.1.e002131.11","doi-asserted-by":"crossref","DOI":"10.3390\/jcm10132899","article-title":"Repeatability and Reproducibility of Macular Hole Size Measurements Using Optical Coherence Tomography","volume":"10","author":"Baumann","year":"2021","journal-title":"J Clin Med"},{"key":"2026010721203847000_10.1.e002131.12","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2023-001531","article-title":"Factors influencing the reliability of measurements in eyes with full-thickness macular holes: are we measuring incorrectly?","volume":"9","author":"Moussa","year":"2024","journal-title":"BMJ Open Ophthalmol"},{"key":"2026010721203847000_10.1.e002131.13","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1016\/j.ajo.2014.01.021","article-title":"Effect of optical coherence tomography scan pattern and density on the detection of full-thickness macular holes","volume":"157","author":"Schneider","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"2026010721203847000_10.1.e002131.14","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.ajo.2018.07.027","article-title":"The Manchester Large Macular Hole Study: Is it Time to Reclassify Large Macular Holes?","volume":"195","author":"Ch\u2019ng","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"2026010721203847000_10.1.e002131.15","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1038\/s41433-020-0844-x","article-title":"Factors affecting anatomical and visual outcome after macular hole surgery: findings from a large prospective UK cohort","volume":"35","author":"Steel","year":"2021","journal-title":"Eye (Lond)"},{"key":"2026010721203847000_10.1.e002131.16","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(86)90837-8"},{"key":"2026010721203847000_10.1.e002131.17","doi-asserted-by":"crossref","DOI":"10.1167\/tvst.10.13.2","article-title":"Defining a Cutoff for Progression of Macular Holes","volume":"10","author":"Baumann","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"2026010721203847000_10.1.e002131.18","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1080\/02713683.2019.1708956","article-title":"How Big is the Hole? Measuring Intra- and Inter-Individual Agreement in Macular Hole Size Measurements","volume":"45","author":"Antonopoulou","year":"2020","journal-title":"Curr Eye Res"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2024-002131","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T05:21:04Z","timestamp":1767849664000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2024-002131"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,5,8]]},"published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1136\/bmjophth-2024-002131"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2024-002131","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5]]}}}