{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T01:07:20Z","timestamp":1790730440977,"version":"4.1.0"},"reference-count":27,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T00:00:00Z","timestamp":1743984000000},"content-version":"unspecified","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2025,3,25]]},"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background\/aims<\/jats:title>\n                    <jats:p>To determine the accuracy of an innovative paper-based, low-cost, easily accessed, portable method of evaluating the visual field (VF).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two groups of consecutive patients with glaucoma and controls were enrolled. Both eyes were assessed, and the Humphrey field analyser (HFA) (24-2) was used to identify patients with and without VF defects. The TsiogkaSpaeth grid (TS) grid test was performed in each eye of all participants. The Humphrey VF examination and the TS grid examination were conducted consecutively on the same day by two different examiners, prior to any other eye examinations. Sensitivity, specificity, and positive and negative predictive values of the TS grid scotoma area were assessed, using the results found with the HFA as the reference standard. A mixed-effects logistic regression model with a random intercept per participant was used to account for the correlation between eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>This prospective, cross-sectional study recruited 51 participants in a tertiary care hospital-based glaucoma department. Of them, 19 had glaucomatous defects in both eyes, 12 had defects in 1 eye only and 21 had no defects in either eye. The sensitivity and specificity of the TS grid test were 81.63% (95% CI 68% to 91.2%) and 84.91% (95% CI 72.4% to 93.3%), respectively, positive predicted value was 83.33% (95% CI 69.8% to 92.5%) and negative predictive value was 83.33% (95% CI 70.7% to 92.1%). The area under the curve was 0.83 (95% CI 0.76 to 0.91). There was a significant correlation between the TS grid test score and the VF Index of the HFA 24-2 (r=0.87, p&lt;0.0001) and the mean deviation of the HFA 24-2 (r=0.85, p&lt;0.0001).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The TS grid test offers a reliable, low-cost alternative for VF examination in glaucoma patients. This method could be advantageous in clinical settings with limited access to traditional testing equipment. The TS grid has limitations, including difficulty of fixation loss testing and ensuring the correct fixation distance. The test\u2019s self-administration reliability is uncertain, and some patients were unable to perform it. Other limitations concern the grid\u2019s design and the small sample size of the study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2025-002144","type":"journal-article","created":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T21:40:12Z","timestamp":1744062012000},"page":"e002144","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Diagnostic accuracy of the TsiogkaSpaeth grid test for detecting visual field defects in patients with glaucoma"],"prefix":"10.1136","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4102-6242","authenticated-orcid":false,"given":"Anastasia","family":"Tsiogka","sequence":"first","affiliation":[{"name":"First Department of Ophthalmology, National and Kapodistrian University of Athens School of Medicine, Athens, Attica, Greece"},{"name":"Ophthalmology Department, 401 General Military Hospital of Athens, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7877-8432","authenticated-orcid":false,"given":"Klio I","family":"Chatzistefanou","sequence":"additional","affiliation":[{"name":"First Department of Ophthalmology, University of Athens, Athens General Hospital \"G.Gennimatas\u201d, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Efthymios","family":"Karmiris","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, Hellenic Air Force General Hospital, Athens, Attiki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evangelia","family":"Samoli","sequence":"additional","affiliation":[{"name":"Department of Hygiene, Epidemiology & Medical Statistics, University of Athens, Medical School, Athens, Attiki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantina","family":"Koulotsiou","sequence":"additional","affiliation":[{"name":"Ophthalmology, National and Kapodistrian University of Athens Gennimatas University Hospital, Athens, Attica, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasileios","family":"Papastavrou","sequence":"additional","affiliation":[{"name":"First Department of Ophthalmology, School of Medicine General Hospital of Athens \u2018\u2019G Gennimatas\u2019\u2019, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgios I","family":"Triantafyllopoulos","sequence":"additional","affiliation":[{"name":"401 General Military Hospital of Athens, Athens, Attica, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitrios","family":"Papaconstantinou","sequence":"additional","affiliation":[{"name":"First Department of Ophthalmology, University of Athens, Athens General Hospital \"G.Gennimatas\u201d, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4964-5024","authenticated-orcid":false,"given":"George L","family":"Spaeth","sequence":"additional","affiliation":[{"name":"Glaucoma, Wills Eye Hospital, Philadelphia, Pennsylvania, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,4,7]]},"reference":[{"key":"2026010721203767000_10.1.e002144.1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2014.3192"},{"key":"2026010721203767000_10.1.e002144.2","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2023-001386","article-title":"Risk factors associated with elevated intraocular pressure: a population-based study in a rural community of Bangladesh","volume":"8","author":"Sharfuddin Ahmed","year":"2023","journal-title":"BMJ Open Ophthalmol"},{"key":"2026010721203767000_10.1.e002144.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.05.013"},{"key":"2026010721203767000_10.1.e002144.4","doi-asserted-by":"publisher","DOI":"10.1007\/s40135-022-00292-6"},{"key":"2026010721203767000_10.1.e002144.5","doi-asserted-by":"crossref","first-page":"591","DOI":"10.2147\/CEOR.S218277","article-title":"Management Of Glaucoma In Developing Countries: Challenges And Opportunities For Improvement","volume":"11","author":"Delgado","year":"2019","journal-title":"Clinicoecon Outcomes Res"},{"key":"2026010721203767000_10.1.e002144.6","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(10)61423-7"},{"key":"2026010721203767000_10.1.e002144.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.01.043"},{"key":"2026010721203767000_10.1.e002144.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.08.023"},{"key":"2026010721203767000_10.1.e002144.9","first-page":"49","article-title":"Racial Disparities in Glaucoma: From Epidemiology to Pathophysiology","volume":"119","author":"Siegfried","year":"2022","journal-title":"Mo Med"},{"key":"2026010721203767000_10.1.e002144.10","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1001\/jamaophthalmol.2017.0738","article-title":"Detecting Glaucoma With a Portable Brain-Computer Interface for Objective Assessment of Visual Function Loss","volume":"135","author":"Nakanishi","year":"2017","journal-title":"JAMA Ophthalmol"},{"key":"2026010721203767000_10.1.e002144.11","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.2147\/OPTH.S131160","article-title":"Visual field examination method using virtual reality glasses compared with the Humphrey perimeter","volume":"11","author":"Tsapakis","year":"2017","journal-title":"Clin Ophthalmol"},{"key":"2026010721203767000_10.1.e002144.12","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-305223"},{"key":"2026010721203767000_10.1.e002144.13","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000461"},{"key":"2026010721203767000_10.1.e002144.14","doi-asserted-by":"crossref","first-page":"2869","DOI":"10.1007\/s10072-024-07305-1","article-title":"The TsiogkaSpaeth grid for detection of neurological visual field defects: a validation study","volume":"45","author":"Tsiogka","year":"2024","journal-title":"Neurol Sci"},{"key":"2026010721203767000_10.1.e002144.15","unstructured":"Parthasarathi P , Stokkermans TJ . Tests for potential vision. In: StatPearls. Treasure Island (FL): StatPearls Publishing, 2023."},{"key":"2026010721203767000_10.1.e002144.16","unstructured":"Hodapp E , Parrish RK , Anderson DR . Clinical decisions in glaucoma. St. Louis, MO: The CV Mosby Co, 1993:52\u201361."},{"key":"2026010721203767000_10.1.e002144.17","doi-asserted-by":"crossref","DOI":"10.3352\/jeehp.2021.18.17","article-title":"Sample size determination and power analysis using the G*Power software","volume":"18","author":"Kang","year":"2021","journal-title":"J Educ Eval Health Prof"},{"key":"2026010721203767000_10.1.e002144.18","first-page":"66","article-title":"Visual field testing for glaucoma - a practical guide","volume":"25","author":"Broadway","year":"2012","journal-title":"Community Eye Health"},{"key":"2026010721203767000_10.1.e002144.19","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1038\/s41433-019-0637-2","article-title":"Advanced glaucoma at diagnosis: current perspectives","volume":"34","author":"Kastner","year":"2020","journal-title":"Eye (Lond)"},{"key":"2026010721203767000_10.1.e002144.20","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.38506.594977.E0"},{"key":"2026010721203767000_10.1.e002144.21","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1016\/S0161-6420(96)30554-X","article-title":"Automated perimetry. American Academy of Ophthalmology","volume":"103","year":"1996","journal-title":"Ophthalmology"},{"key":"2026010721203767000_10.1.e002144.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.03.019"},{"key":"2026010721203767000_10.1.e002144.23","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.69.12.927"},{"key":"2026010721203767000_10.1.e002144.24","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/j.ophtha.2015.12.003","article-title":"Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects","volume":"123","author":"Su","year":"2016","journal-title":"Ophthalmology"},{"key":"2026010721203767000_10.1.e002144.25","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1038\/eye.1993.24","article-title":"Oculokinetic perimetry compared with Humphrey visual field analysis in the detection of glaucomatous visual field loss","volume":"7 (Pt 1)","author":"Wishart","year":"1993","journal-title":"Eye (Lond)"},{"key":"2026010721203767000_10.1.e002144.26","unstructured":"Jain AK , Goel R . Visual field mapping by Tangent Screen and Humphrey perimetry: a comparative study. 2016."},{"key":"2026010721203767000_10.1.e002144.27","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/IJG.0000000000002336","article-title":"Caronia Glaucoma Card Versus Amsler Grid for Monitoring Patients With Advanced Glaucoma","volume":"33","author":"Caronia","year":"2024","journal-title":"J Glaucoma"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2025-002144","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T05:21:06Z","timestamp":1767849666000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2025-002144"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,4,7]]},"published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.1136\/bmjophth-2025-002144"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2025-002144","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}