{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T18:07:24Z","timestamp":1780423644752,"version":"3.54.1"},"reference-count":24,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"unspecified","delay-in-days":62,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2026,5,9]]},"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Refractive errors cause significant preventable visual impairment globally, particularly in underserved areas. Conventional subjective refraction remains the gold standard but proves examiner-dependent, time-consuming and challenging in high-volume settings. The 3nethra Specto, a wearable digital subjective refractometer, offers rapid refractive assessment. This study evaluates its accuracy and repeatability versus conventional methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A prospective comparative study was conducted on 135 subjects who underwent both conventional subjective refraction and 3nethra Specto assessment. Spherical (S), cylindrical (C) and axis measurements were analysed using power vector transformation (J\u2080, J\u2084\u2085). Primary predictive validity was assessed using univariate general linear models (GLMs) (IBM SPSS V.25.0) with age\/sex as covariates. Model fit was evaluated via F-statistics, R\u00b2 and residual SD. Instrument repeatability used GLM Repeated Measures, agreement assessed via Bland-Altman plots, keeping significance at p&lt;0.05. Patient and examiner feedback on the instrument was captured using the User Experience questionnaire.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Of 135 adults (mean age 31.5\u00b18.9 years; 60% male), compound myopic astigmatism predominated (45%). 3nethra Specto measurements closely matched subjective refraction (sphere: \u22121.02 D vs \u22120.99 D; cylinder: \u22120.49 D vs \u22120.83 D; M: \u22121.26 D vs \u22121.24 D). GLM analysis showed excellent predictive validity (all p&lt;0.001; R\u00b2 0.914 to 0.994; residual SD 0.084 D to 0.228 D). Bland-Altman plots confirmed 95% limits of agreement of \u22120.39 D to +0.47 D for M and \u22120.62 D to +0.64 D for J\u2080 and \u22120.32 D to +0.35 D for J\u2084\u2085. Device repeatability was high (all F&gt;96, p&lt;0.001; R\u00b2\u22650.956; residual SD\u22640.148 D). Patients rated subjective refraction higher for comfort\/enjoyability but found 3nethra more inventive\/exciting; examiners preferred 3nethra for efficiency, speed, innovation and ease of use.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The 3nethra Specto wearable liquid lens refractor demonstrated excellent agreement and repeatability with traditional subjective refraction across all refractive parameters, confirming clinical equivalence. Positive patient and examiner feedback highlighted its innovation, efficiency and usability. This device offers a reliable alternative for routine refractive assessment in clinical settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2025-002553","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T17:45:15Z","timestamp":1780422315000},"page":"e002553","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Validation of 3nethra specto, a wearable digital subjective refractor versus conventional subjective refraction for refractive error measurement in young adults: a comparative study"],"prefix":"10.1136","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1385-3227","authenticated-orcid":false,"given":"Kaushik","family":"Murali","sequence":"first","affiliation":[{"name":"Department of Paediatric Ophthalmology and Strabismus, Sankara Eye Hospital, Sankara Academy of Vision, Sankara Eye Foundation India, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6787-7830","authenticated-orcid":false,"given":"Namratha","family":"Hegde","sequence":"additional","affiliation":[{"name":"Sankara Academy of Vision, Sankara Eye Foundation India, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3279-7601","authenticated-orcid":false,"given":"Afia","family":"S","sequence":"additional","affiliation":[{"name":"Sankara College of Optometry, Sankara Academy of Vision, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6995-0169","authenticated-orcid":false,"given":"Varshini","family":"M","sequence":"additional","affiliation":[{"name":"Sankara College of Optometry, Sankara Academy of Vision, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-8272-2749","authenticated-orcid":false,"given":"Disha","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Department of Paediatric Ophthalmology and Strabismus, Sankara Eye Hospital, Sankara Academy of Vision, Sankara Eye Foundation India, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-3240-8839","authenticated-orcid":false,"given":"Revathy","family":"Manthri Rangaraj","sequence":"additional","affiliation":[{"name":"Research and Development, Forus Health Pvt Ltd, Bangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3249-4254","authenticated-orcid":false,"given":"Rashmi","family":"Hullur","sequence":"additional","affiliation":[{"name":"Research and Development, Forus Health Pvt Ltd, Bangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-6400-4839","authenticated-orcid":false,"given":"Kousar","family":"Sidiq","sequence":"additional","affiliation":[{"name":"Research and Development, Forus Health Pvt Ltd, Bangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2783-6475","authenticated-orcid":false,"given":"Venkatakrishnan","family":"S","sequence":"additional","affiliation":[{"name":"Research and Development, Forus Health Pvt Ltd, Bangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,6,2]]},"reference":[{"key":"2026060210450974000_11.2.e002553.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joco.2017.08.009"},{"key":"2026060210450974000_11.2.e002553.2","unstructured":"Eye care, vision impairment and blindness_ refractive errors. 2024. Available: https:\/\/www.who.int\/news-room\/questions-and-answers\/item\/blindness-and-vision-impairment-refractive-errors"},{"key":"2026060210450974000_11.2.e002553.3","doi-asserted-by":"publisher","DOI":"10.1136\/bjo-2024-325427"},{"key":"2026060210450974000_11.2.e002553.4","doi-asserted-by":"crossref","first-page":"011","DOI":"10.29328\/journal.ijceo.1001061","article-title":"Impact of Refractive Error Correction on Vision Related Quality of Life in School-Aged Children-A Prospective Interventional Study","volume":"9","author":"Rathi","year":"2025","journal-title":"Int J Clin Exp Ophthalmol"},{"key":"2026060210450974000_11.2.e002553.5","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1111\/ceo.12954","article-title":"Impact of refractive error on quality of life: a qualitative study","volume":"45","author":"Kandel","year":"2017","journal-title":"Clin Exp Ophthalmol"},{"key":"2026060210450974000_11.2.e002553.6","first-page":"619","article-title":"Reliability of refraction--a literature review","volume":"67","author":"Goss","year":"1996","journal-title":"J Am Optom Assoc"},{"key":"2026060210450974000_11.2.e002553.7","unstructured":"Aggarwal A , Gairola S , Upadhyay U , et al . Towards automating retinoscopy for refractive error diagnosis. 2022. Available: http:\/\/arxiv.org\/abs\/2208.05552"},{"key":"2026060210450974000_11.2.e002553.8","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.optom.2018.09.001","article-title":"Clinical evaluation of an automated subjective refraction method implemented in a computer-controlled motorized phoropter","volume":"12","author":"Otero","year":"2019","journal-title":"J Optom"},{"key":"2026060210450974000_11.2.e002553.9","unstructured":"Schrepp M , Hinderks A , Thomaschewski J . Applying the user experience questionnaire (UEQ) in different evaluation scenarios. 2011."},{"key":"2026060210450974000_11.2.e002553.10","doi-asserted-by":"crossref","first-page":"40","DOI":"10.9781\/ijimai.2017.445","article-title":"Construction of a Benchmark for the User Experience Questionnaire (UEQ)","volume":"4","author":"Schrepp","year":"2017","journal-title":"IJIMAI"},{"key":"2026060210450974000_11.2.e002553.11","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-7641"},{"key":"2026060210450974000_11.2.e002553.12","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/OPX.0000000000001465","article-title":"A Review of the Use of Confidence Intervals for Bland-Altman Limits of Agreement in Optometry and Vision Science","volume":"97","author":"Carkeet","year":"2020","journal-title":"Optom Vis Sci"},{"key":"2026060210450974000_11.2.e002553.13","doi-asserted-by":"crossref","DOI":"10.1186\/s12886-024-03350-8","article-title":"Refractive error and vision related quality of life","volume":"24","author":"Rajabpour","year":"2024","journal-title":"BMC Ophthalmol"},{"key":"2026060210450974000_11.2.e002553.14","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2022-068348","article-title":"Integrating eye care in low-income and middle-income settings: a scoping review","volume":"13","author":"Lee","year":"2023","journal-title":"BMJ Open"},{"key":"2026060210450974000_11.2.e002553.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2022.05.020"},{"key":"2026060210450974000_11.2.e002553.16","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0219501","article-title":"Comparing low-cost handheld autorefractors: A practical approach to measuring refraction in low-resource settings","volume":"14","author":"Agarwal","year":"2019","journal-title":"PLoS One"},{"key":"2026060210450974000_11.2.e002553.17","doi-asserted-by":"crossref","DOI":"10.1186\/s12886-024-03340-w","article-title":"Subjective versus objective refraction in healthy young adults","volume":"24","author":"Kozlov","year":"2024","journal-title":"BMC Ophthalmol"},{"key":"2026060210450974000_11.2.e002553.18","doi-asserted-by":"crossref","first-page":"100117","DOI":"10.1016\/j.sintl.2021.100117","article-title":"Telemedicine for healthcare: Capabilities, features, barriers, and applications","volume":"2","author":"Haleem","year":"2021","journal-title":"Sens Int"},{"key":"2026060210450974000_11.2.e002553.19","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200407000-00018"},{"key":"2026060210450974000_11.2.e002553.20","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1167\/tvst.11.11.16","article-title":"The Reliability and Acceptability of RDx-Based Tele-Controlled Subjective Refraction Compared with Traditional Subjective Refraction","volume":"11","author":"Huang","year":"2022","journal-title":"Transl Vis Sci Technol"},{"key":"2026060210450974000_11.2.e002553.21","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199808000-00028"},{"key":"2026060210450974000_11.2.e002553.22","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1007\/s00417-022-05936-8","article-title":"Comparisons of objective and subjective refraction with and without cycloplegia using binocular wavefront optometer with autorefraction and retinoscopy in school-age children","volume":"261","author":"Lei","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"2026060210450974000_11.2.e002553.23","doi-asserted-by":"crossref","first-page":"536","DOI":"10.18502\/jovr.v17i4.12314","article-title":"Clinical Evaluation of the 3nethra Aberro Handheld Autorefractometer","volume":"17","author":"Perumal","year":"2022","journal-title":"J Ophthalmic Vis Res"},{"key":"2026060210450974000_11.2.e002553.24","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1097\/OPX.0000000000002037","article-title":"Comparison of a Novel Binocular Refraction System with Standard Digital Phoropter Refraction","volume":"100","author":"Bossie","year":"2023","journal-title":"Optom Vis Sci"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2025-002553","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T17:45:21Z","timestamp":1780422321000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2025-002553"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,6,2]]},"published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1136\/bmjophth-2025-002553"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2025-002553","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}