{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T14:00:52Z","timestamp":1771855252678,"version":"3.50.1"},"reference-count":39,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2026,2,6]]},"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>\n                      <jats:named-content content-type=\"\">Objective<\/jats:named-content>\n                    <\/jats:title>\n                    <jats:p>To study the properties of different ophthalmic viscosurgical devices (OVDs) with respect to their ability to create and maintain high intraocular pressure (IOP) during the creation of a continuous curvilinear capsulorhexis (CCC) by comparing the drop in IOP before and after creation of the CCC.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>The study included 174 eyes in four groups using two different OVDs (hyaluronic acid (HA) and hydroxypropylmethylcellulose (HPMC)) and two different instruments (utrata forceps (UF) and 26G cystotome (RN)). IOP was measured using rebound tonometry with sterilised probes immediately before the beginning of the CCC and immediately afterwards during cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The drop in IOP during capsulorhexis was measured at 52.1\u00b110.7\u2009mm Hg with the combination HA\/RN, 62.4\u00b111.5\u2009mm Hg with HA\/UF, 60.5\u00b110.0\u2009mm Hg with HPMC\/RN and 68.7\u00b114.1\u2009mm Hg with HPMC\/UF. The variance in IOP reduction between HA and HPMC did not reach statistical significance (p=0.100).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The lack of a noticeable difference in IOP levels, despite the use of different OVDs with unique properties, indicates that IOP may not be the main factor influencing the notable differences in tactile feedback perceived by surgeons during capsulorhexis procedures conducted with varying OVDs. To elucidate these sensations, additional characteristics such as viscosity, elasticity, pseudoplasticity and cohesion will have to be explored.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2025-002573","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T13:00:16Z","timestamp":1771851616000},"page":"e002573","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Intracameral pressure during capsulorhexis in cataract surgery using cohesive versus dispersive ophthalmic viscosurgical devices: a randomised trial"],"prefix":"10.1136","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5936-1826","authenticated-orcid":false,"given":"Daniel M","family":"Handzel","sequence":"first","affiliation":[{"name":"Ophthalmology, Augenzentrum Osthessen, Fulda, Hessen, Germany"},{"name":"Campus Fulda, Philipps-Universitat Marburg, Fulda, Hessen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Walter","family":"Sekundo","sequence":"additional","affiliation":[{"name":"Ophthalmology, Philipps-Universitat Marburg, Marburg, Hessen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiraz","family":"Ben Abdallah","sequence":"additional","affiliation":[{"name":"Ophthalmology, Augenzentrum Osthessen, Fulda, Hessen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus S","family":"Ladewig","sequence":"additional","affiliation":[{"name":"Campus Fulda, Philipps-Universitat Marburg, Fulda, Hessen, Germany"},{"name":"Ophthalmology, Klinikum Fulda, Fulda, Hessen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"key":"2026022305000918000_11.1.e002573.1","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s40123-021-00403-9","article-title":"Ophthalmic Viscosurgical Devices (OVDs) in Challenging Cases: a Review","volume":"10","author":"Borkenstein","year":"2021","journal-title":"Ophthalmol Ther"},{"key":"2026022305000918000_11.1.e002573.2","first-page":"16","article-title":"From Simple Liquids to Surgical Instruments: On the History of Ophthalmo-Viscosurgical Devices (OVD)","volume":"75","author":"Scholtz","year":"2012","journal-title":"Archivum Historii i Filozofii Medyzyny"},{"key":"2026022305000918000_11.1.e002573.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(22)01839-6"},{"key":"2026022305000918000_11.1.e002573.4","unstructured":"Auffarth GU . Viskoelastische Substanzen in Der Ophthalmochirurgie. Bremen: UNI-Med Verlag, 2001."},{"key":"2026022305000918000_11.1.e002573.5","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1093\/ajhp\/zxab228","article-title":"A primer on ocular viscosurgical devices","volume":"78","author":"Gerberich","year":"2021","journal-title":"Am J Health Syst Pharm"},{"key":"2026022305000918000_11.1.e002573.6","doi-asserted-by":"crossref","DOI":"10.1155\/2020\/2159363","article-title":"Effects of Combinations of Ophthalmic Viscosurgical Devices and Suction Flow Rates on the Corneal Endothelial Cell Damage Incurred during Phacoemulsification","volume":"2020","author":"Kunishige","year":"2020","journal-title":"J Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.7","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/S0886-3350(13)81001-2","article-title":"Continuous curvilinear capsulorhexis","volume":"17","author":"Gimbel","year":"1991","journal-title":"J Cataract Refract Surg"},{"key":"2026022305000918000_11.1.e002573.8","first-page":"111","article-title":"Scheimpflug imaging criteria for identifying eyes at high risk of acute angle closure","volume":"7","author":"Pakravan","year":"2012","journal-title":"J Ophthalmic Vis Res"},{"key":"2026022305000918000_11.1.e002573.9","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/1471-2415-13-44","article-title":"Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions","volume":"13","author":"Schweier","year":"2013","journal-title":"BMC Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.10","doi-asserted-by":"crossref","first-page":"1879","DOI":"10.1016\/j.jcrs.2014.04.025","article-title":"Corneal endothelial cell coating during phacoemulsification using a new dispersive hyaluronic acid ophthalmic viscosurgical device","volume":"40","author":"Kretz","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"2026022305000918000_11.1.e002573.11","doi-asserted-by":"crossref","DOI":"10.1136\/bmjophth-2018-000227","article-title":"Dispersive viscosurgical devices demonstrate greater efficacy in protecting corneal endothelium in vitro","volume":"4","author":"Yildirim","year":"2019","journal-title":"BMJ Open Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.12","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.ogla.2020.04.015","article-title":"The Pressure: Before and after Schi\u00f8tz","volume":"3","author":"Albert","year":"2020","journal-title":"Ophthalmol Glaucoma"},{"key":"2026022305000918000_11.1.e002573.13","first-page":"132","article-title":"Direct intraoperative continuous monitoring of intraocular pressure","volume":"23","author":"Blumenthal","year":"1992","journal-title":"Ophthalmic Surg"},{"key":"2026022305000918000_11.1.e002573.14","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jaapos.2016.01.003","article-title":"Rebound tonometry over an air-filled anterior chamber in the supine child after intraocular surgery","volume":"20","author":"Davis","year":"2016","journal-title":"J AAPOS"},{"key":"2026022305000918000_11.1.e002573.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.08.062"},{"key":"2026022305000918000_11.1.e002573.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.07.035"},{"key":"2026022305000918000_11.1.e002573.17","first-page":"S102","article-title":"Agreement and reproducibility of Tono-Pen XL tip covered with ocufilm and fingertip of surgical glove in intra-ocular pressure measurement","volume":"95 Suppl 4","author":"Sayawat","year":"2012","journal-title":"J Med Assoc Thai"},{"key":"2026022305000918000_11.1.e002573.18","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0239875","article-title":"Repeatability, reproducibility, agreement, and safety of Tono-Pen tip cover for intraocular measurement using latex and polyethylene wrap","volume":"15","author":"Suvannachart","year":"2020","journal-title":"PLoS One"},{"key":"2026022305000918000_11.1.e002573.19","doi-asserted-by":"crossref","unstructured":"Pinelli RPF . Dynamics of the capsulorhexis. In: Garg A , Fine IH , Alio JL , et al , eds. Mastering the Phacodynamics. New Delhi: Jaypee Brothers, 2007: 111\u20135.","DOI":"10.5005\/jp\/books\/10497_12"},{"key":"2026022305000918000_11.1.e002573.20","unstructured":"Seibel BE . Phacodynamics: Mastering the Tools and Techniques of Phacoemulsification Surgery. 4th edn. SLACK Inc, 2004:400."},{"key":"2026022305000918000_11.1.e002573.21","doi-asserted-by":"crossref","first-page":"104545","DOI":"10.1016\/j.jfo.2025.104545","article-title":"Validation of iCare IC200\u00ae rebound tonometry for intraocular pressure measurement","volume":"48","author":"Vieyres","year":"2025","journal-title":"J Fr Ophtalmol"},{"key":"2026022305000918000_11.1.e002573.22","unstructured":"Bader J , Zeppieri M . Treasure island (fl) ineligible companies. disclosure: marco zeppieri declares no relevant financial relationships with ineligible companies. Disclosure: shane havens declares no relevant financial relationships with ineligible companies. 2024."},{"key":"2026022305000918000_11.1.e002573.23","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0586"},{"key":"2026022305000918000_11.1.e002573.24","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1007\/s00347-023-01886-6","article-title":"Rebound tonometry with sterilized probes","volume":"120","author":"Handzel","year":"2023","journal-title":"Ophthalmologie"},{"key":"2026022305000918000_11.1.e002573.25","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1097\/ICU.0000000000000612","article-title":"Relationship between sleep position and glaucoma progression","volume":"30","author":"Kaplowitz","year":"2019","journal-title":"Curr Opin Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.26","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1007\/s00347-019-0908-0","article-title":"Application of rebound self-tonometry for measurements in a supine position","volume":"116","author":"Amani","year":"2019","journal-title":"Ophthalmologe"},{"key":"2026022305000918000_11.1.e002573.27","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182972df4"},{"key":"2026022305000918000_11.1.e002573.28","doi-asserted-by":"crossref","DOI":"10.1097\/j.jcro.0000000000000137","article-title":"Intraoperative measurement of intraocular pressure using a handheld rebound tonometer with sterilized probes: simple method for intraoperative tonometry","volume":"13","author":"Handzel","year":"2025","journal-title":"JCRS Online Case Rep"},{"key":"2026022305000918000_11.1.e002573.29","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.18240\/ijo.2024.06.22","article-title":"Intraocular pressure before and after capsulorhexis using two viscoelastic substances and two surgical approaches in enucleated porcine eyes","volume":"17","author":"Ben Abdallah","year":"2024","journal-title":"Int J Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.30","doi-asserted-by":"publisher","DOI":"10.1111\/j.1369-7625.2012.00795.x"},{"key":"2026022305000918000_11.1.e002573.31","doi-asserted-by":"crossref","first-page":"R95","DOI":"10.1055\/s-0031-1280025","article-title":"Acute angle closure, chronic angle-closure glaucoma and their differential diagnoses","volume":"228","author":"Schwenn","year":"2011","journal-title":"Klin Monbl Augenheilkd"},{"key":"2026022305000918000_11.1.e002573.32","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/ICU.0b013e328343729f","article-title":"Classification of primary angle closure disease","volume":"22","author":"Sihota","year":"2011","journal-title":"Curr Opin Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.33","unstructured":"Olson RJ , Braga-Mele R , Chen SH , et al . Cataract in the adult eye preferred practice pattern. 2016. Available: https:\/\/www.aaojournal.org\/article\/S0161-6420(16)31418-X\/pdf"},{"key":"2026022305000918000_11.1.e002573.34","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.03.006"},{"key":"2026022305000918000_11.1.e002573.35","doi-asserted-by":"crossref","first-page":"2809","DOI":"10.1007\/s00417-025-06867-w","article-title":"Comparative analysis of anterior chamber stability with a cohesive ophthalmic viscosurgical device versus the soft-shell technique","volume":"263","author":"Handzel","year":"2025","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"2026022305000918000_11.1.e002573.36","article-title":"Lens extraction for chronic angle-closure glaucoma","volume":"3","author":"Ong","year":"2021","journal-title":"Cochrane Database Syst Rev"},{"key":"2026022305000918000_11.1.e002573.37","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(63)92431-0"},{"key":"2026022305000918000_11.1.e002573.38","first-page":"56","article-title":"CHANGES IN BLOOD AND INTRAOCULAR PRESSURE ON DIFFERENT STEPS OF CATARACT PHACOEMULSIFICATION","volume":"2021","author":"Javrishvili","year":"2021","journal-title":"Georgian Med News"},{"key":"2026022305000918000_11.1.e002573.39","doi-asserted-by":"crossref","first-page":"75","DOI":"10.5507\/bp.2018.065","article-title":"Intraoperative intraocular pressure fluctuation during standard phacoemulsification in real human patients","volume":"163","author":"Hejsek","year":"2019","journal-title":"Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2025-002573","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T13:00:19Z","timestamp":1771851619000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2025-002573"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,23]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2,23]]},"published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1136\/bmjophth-2025-002573"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2025-002573","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,23]]}}}