{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T13:29:29Z","timestamp":1787232569441,"version":"build-2736575974"},"reference-count":22,"publisher":"BMJ","issue":"3","license":[{"start":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T00:00:00Z","timestamp":1787184000000},"content-version":"unspecified","delay-in-days":50,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Ophth"],"accepted":{"date-parts":[[2026,8,2]]},"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the estimated lens diameter (eLD) of the crystalline lens in a large European cohort.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>Data sets from an Austrian population acquired between 2020 and 2022 were analysed in this study. Measurements included optical biometry (IOLMaster 700, Carl Zeiss Meditec AG, Germany) as well as anterior segment optical coherence tomography (CASIA2, Tomey, Japan). For eLD prediction, three different machine learning approaches were implemented.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In total, 2352 eyes of 2352 patients were included in this study. The eLD was normally distributed with a mean value of 10.18\u00b10.56\u2009mm, showing a statistically significant difference (p=0.008) between females and males (10.16\u00b10.54\u2009mm and 10.22\u00b10.57\u2009mm, respectively). There was a low but significant correlation (p&lt;0.01 for all) with age (r=0.246), lens thickness (r=0.265), white-to-white (r=0.122), corneal radii (r=0.090), axial eye length (r=0.092), anterior chamber depth (r=\u22120.060), decentration (r=\u22120.087) and tilt (r=\u22120.159), respectively. Subanalysis of short and long eyes yielded no significant difference in eLD. For eLD prediction, age and lens thickness appeared to be relevant parameters, with all three models demonstrating low predictive accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The crystalline lens diameter followed a normal distribution with no significant differences between short and long eyes. All three models demonstrated low predictive accuracies, suggesting that reliable prediction of eLD is currently not attainable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjophth-2026-002819","type":"journal-article","created":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T13:05:13Z","timestamp":1787231113000},"page":"e002819","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of the crystalline lens diameter using swept-source optical coherence tomography"],"prefix":"10.1136","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3919-0249","authenticated-orcid":false,"given":"Sophia Anna","family":"Reifeltshammer","sequence":"first","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0369-5237","authenticated-orcid":false,"given":"Haidar","family":"Khalil","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa","family":"H\u00f6ftberger","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Laubichler","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leon","family":"Pomberger","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klemens","family":"Waser","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"},{"name":"Smile Eyes, Trier, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8691-5276","authenticated-orcid":false,"given":"Matthias","family":"Bolz","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nino","family":"Hirnschall","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria"},{"name":"Department for Ophthalmology and Optometry, Johannes Kepler University, Linz, Upper Austria, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,8,20]]},"reference":[{"key":"2026082006050509000_11.3.e002819.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.031"},{"key":"2026082006050509000_11.3.e002819.2","doi-asserted-by":"crossref","DOI":"10.1155\/2019\/8319027","article-title":"Panoramic observation of crystalline lenses with 25 MHz ultrasonography","volume":"2019","author":"Xue","year":"2019","journal-title":"J Ophthalmol"},{"key":"2026082006050509000_11.3.e002819.3","first-page":"1162","article-title":"Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study","volume":"40","author":"Strenk","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2026082006050509000_11.3.e002819.4","doi-asserted-by":"crossref","first-page":"108653","DOI":"10.1016\/j.exer.2021.108653","article-title":"Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age","volume":"209","author":"Mohamed","year":"2021","journal-title":"Exp Eye Res"},{"key":"2026082006050509000_11.3.e002819.5","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-10619"},{"key":"2026082006050509000_11.3.e002819.6","doi-asserted-by":"crossref","first-page":"6847","DOI":"10.1167\/iovs.15-17228","article-title":"Predicting lens diameter: ocular biometry with high-resolution MRI","volume":"56","author":"Erb-Eigner","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2026082006050509000_11.3.e002819.7","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.ajo.2020.12.021","article-title":"Correlation of intraoperative optical coherence tomography of crystalline lens diameter, thickness, and volume with biometry and age","volume":"225","author":"Waring","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"2026082006050509000_11.3.e002819.8","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1097\/j.jcrs.0000000000001194","article-title":"Distribution and associated factors of crystalline lens volume in noncataract adolescents and adults and patients with cataract in a Chinese population","volume":"49","author":"Chen","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"2026082006050509000_11.3.e002819.9","doi-asserted-by":"crossref","first-page":"53","DOI":"10.33160\/yam.2022.02.010","article-title":"Intraoperative measurement of crystalline lens diameter in living humans","volume":"65","author":"Nagase","year":"2022","journal-title":"Yonago Acta Med"},{"key":"2026082006050509000_11.3.e002819.10","doi-asserted-by":"crossref","unstructured":"Rodriguez-Sanchez J , Ansah DO , de Castro A , et al . Crystalline lens geometry from a clinical OCT-based biometer in pre-cataract surgery patients. In Review [Preprint] 2026. doi:10.21203\/rs.3.rs-9137111\/v1","DOI":"10.21203\/rs.3.rs-9137111\/v1"},{"key":"2026082006050509000_11.3.e002819.11","doi-asserted-by":"crossref","first-page":"3029","DOI":"10.21037\/qims-20-1124","article-title":"Ultrahigh field MRI determination of water diffusion rates in ex vivo human lenses of different age","volume":"11","author":"Stahnke","year":"2021","journal-title":"Quant Imaging Med Surg"},{"key":"2026082006050509000_11.3.e002819.12","doi-asserted-by":"crossref","DOI":"10.1167\/iovs.61.4.11","article-title":"Age-related changes to the three-dimensional full shape of the isolated human crystalline lens","volume":"61","author":"Martinez-Enriquez","year":"2020","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2026082006050509000_11.3.e002819.13","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1364\/BOE.9.001272","article-title":"Change in human lens dimensions, lens refractive index distribution and ciliary body ring diameter with accommodation","volume":"9","author":"Khan","year":"2018","journal-title":"Biomed Opt Express"},{"key":"2026082006050509000_11.3.e002819.14","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1364\/BOE.8.000918","article-title":"OCT-based full crystalline lens shape change during accommodation in vivo","volume":"8","author":"Martinez-Enriquez","year":"2017","journal-title":"Biomed Opt Express"},{"key":"2026082006050509000_11.3.e002819.15","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8645"},{"key":"2026082006050509000_11.3.e002819.16","doi-asserted-by":"crossref","first-page":"5633","DOI":"10.1364\/BOE.397695","article-title":"Eigenlenses: a new model for full crystalline lens shape representation and its applications","volume":"11","author":"Martinez-Enriquez","year":"2020","journal-title":"Biomed Opt Express"},{"key":"2026082006050509000_11.3.e002819.17","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.ajo.2025.10.015","article-title":"Evaluation of crystalline lens equatorial plane: a novel SS-OCT biometry parameter for predicting postoperative intraocular lens position","volume":"282","author":"Romero","year":"2026","journal-title":"Am J Ophthalmol"},{"key":"2026082006050509000_11.3.e002819.18","doi-asserted-by":"crossref","DOI":"10.1007\/s10792-024-03126-5","article-title":"An analysis of the factors involved in IOL decentration after phacoemulsification using CASIA 2 anterior segment optical coherence tomography","volume":"44","author":"de Paula","year":"2024","journal-title":"Int Ophthalmol"},{"key":"2026082006050509000_11.3.e002819.19","doi-asserted-by":"crossref","DOI":"10.1016\/j.heliyon.2024.e29780","article-title":"Analysis of intraocular lens decentration and tilt after femtosecond laser-assisted cataract surgery using swept-source anterior optical coherence tomography","volume":"10","author":"Lee","year":"2024","journal-title":"Heliyon"},{"key":"2026082006050509000_11.3.e002819.20","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-020-63546-y","article-title":"Development of a new intraocular lens power calculation method based on lens position estimated with optical coherence tomography","volume":"10","author":"Satou","year":"2020","journal-title":"Sci Rep"},{"key":"2026082006050509000_11.3.e002819.21","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1055\/a-1298-8121","article-title":"Artificial intelligence, machine learning and calculation of intraocular lens power","volume":"237","author":"Langenbucher","year":"2020","journal-title":"Klin Monbl Augenheilkd"},{"key":"2026082006050509000_11.3.e002819.22","doi-asserted-by":"crossref","first-page":"OCT600","DOI":"10.1167\/iovs.15-18933","article-title":"Optical coherence tomography based estimates of crystalline lens volume, equatorial diameter, and plane position","volume":"57","author":"Martinez-Enriquez","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["BMJ Open Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjophth-2026-002819","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T13:05:16Z","timestamp":1787231116000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjophth.bmj.com\/lookup\/doi\/10.1136\/bmjophth-2026-002819"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,8,20]]},"published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1136\/bmjophth-2026-002819"],"URL":"https:\/\/doi.org\/10.1136\/bmjophth-2026-002819","relation":{},"ISSN":["2397-3269"],"issn-type":[{"value":"2397-3269","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]}}}