{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T19:45:39Z","timestamp":1767987939869,"version":"3.49.0"},"reference-count":13,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T00:00:00Z","timestamp":1767916800000},"content-version":"unspecified","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Qual"],"accepted":{"date-parts":[[2025,12,3]]},"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:p>Sepsis resulting from bloodstream infection is a medical emergency, especially in immunocompromised haematology patients. Identification of causative pathogens through blood cultures is crucial for delivering effective antibiotics promptly.<\/jats:p>\n                  <jats:p>Adequate blood culture volumes (BCV) are crucial for detecting bloodstream infections. Guidelines recommend 8\u201310\u2009mL per blood culture bottle, yet achieving these volumes remains challenging. In our haematology wards, baseline mean BCV was suboptimal at 4.5\u2009mL. This quality improvement project aimed to optimise BCVs to recommended levels within 6\u2009months at a Singapore tertiary hospital\u2019s Department of Haematology.<\/jats:p>\n                  <jats:p>We implemented a multistakeholder quality improvement across three haematology wards from January 2023 to January 2025. Three Plan-Do-Study-Act cycles were executed from July 2024: (1) staff education and stakeholder engagement, (2) equipment and process enhancement and (3) validation of BCV measurements through comparison of an automated BCV measurement system (BD EpiCenter BACTEC Microbiology Data Management System) against manual bottle weighing.<\/jats:p>\n                  <jats:p>Postintervention data demonstrated clear statistical signals of improvements in BCV through both EpiCenter automated system and manual bottle weighing. Manual validation in selected wards demonstrated achievement of target volumes. Importantly, this validation process revealed potential limitations of automated measurement systems in our specialised clinical setting. Overall, our results demonstrate that a well-coordinated, multidisciplinary approach combining staff education and engagement, improved equipment and BCV measurement process can successfully achieve recommended BCV in our complex haematology settings.<\/jats:p>","DOI":"10.1136\/bmjoq-2025-003497","type":"journal-article","created":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T14:40:17Z","timestamp":1767969617000},"page":"e003497","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Quality improvement project to improve blood culture volumes in haematology patients"],"prefix":"10.1136","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7321-710X","authenticated-orcid":false,"given":"Chan","family":"Yuen Yue Candice","sequence":"first","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tan Yen","family":"Ee","sequence":"additional","affiliation":[{"name":"Department of Microbiology, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tee","family":"Ning","sequence":"additional","affiliation":[{"name":"Department of Specialty Nursing, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ng Hui Ling","family":"Dorothy","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wong Hei Man","family":"Anson","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chan Fu Zi","family":"Yvonne","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sim Xiang Ying","family":"Jean","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheong May","family":"Anne","sequence":"additional","affiliation":[{"name":"Department of Haematology, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Khaing Mon Nanda","family":"Kyaw Isabella","sequence":"additional","affiliation":[{"name":"Process Transformation and Improvement Division: Organisation Planning and Performance, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chlebicki Maciej","family":"Piotr","sequence":"additional","affiliation":[{"name":"Department of Infectious Diseases, Singapore General Hospital, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,1,9]]},"reference":[{"key":"2026010906401282000_15.1.e003497.1","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s15010-004-3049-5","article-title":"Bloodstream infections in patients with solid tumors: associated factors, microbial spectrum and outcome","volume":"32","author":"Anatoliotaki","year":"2004","journal-title":"Infection"},{"key":"2026010906401282000_15.1.e003497.2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000000026"},{"key":"2026010906401282000_15.1.e003497.3","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-0691.2005.01298.x"},{"key":"2026010906401282000_15.1.e003497.4","doi-asserted-by":"crossref","DOI":"10.1128\/JCM.00268-19","article-title":"Detailed Analysis of the Characteristics of Sample Volume in Blood Culture Bottles","volume":"57","author":"Henning","year":"2019","journal-title":"J Clin Microbiol"},{"key":"2026010906401282000_15.1.e003497.5","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.00140-07"},{"key":"2026010906401282000_15.1.e003497.6","doi-asserted-by":"crossref","DOI":"10.1016\/j.infpip.2019.100007","article-title":"Increasing the volume of blood received in adult paired blood culture bottles at a regional public health laboratory: results of a quality improvement project to optimise the diagnosis of bacteraemia","volume":"1","author":"Birkhamshaw","year":"2019","journal-title":"Infect Prev Pract"},{"key":"2026010906401282000_15.1.e003497.7","doi-asserted-by":"crossref","DOI":"10.1136\/bmjoq-2017-000228","article-title":"Education and coaching to optimise blood culture volumes: continuous quality improvement in microbiology","volume":"7","author":"Libertin","year":"2018","journal-title":"BMJ Open Qual"},{"key":"2026010906401282000_15.1.e003497.8","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1136\/bmjebm-2017-110853","article-title":"Methodological quality and synthesis of case series and case reports","volume":"23","author":"Murad","year":"2018","journal-title":"BMJ EBM"},{"key":"2026010906401282000_15.1.e003497.9","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.cll.2020.07.001","article-title":"Modern Blood Culture","volume":"40","author":"Gonzalez","year":"2020","journal-title":"Clin Lab Med"},{"key":"2026010906401282000_15.1.e003497.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.diagmicrobio.2014.11.001"},{"key":"2026010906401282000_15.1.e003497.11","unstructured":"BD . BD vacutainer ultratouch push button blood collection set. 2022. Available: https:\/\/lp.bd.com\/rs\/328-BFZ-688\/images\/FY22-EMEA-IDS-SA-UltraTouch-Blood-Culture%20SS-PRNT_D-Veeva-57297.pdf"},{"key":"2026010906401282000_15.1.e003497.12","unstructured":"Pathologists TRC of . Blood culture pathway. Available: https:\/\/www.rcpath.org\/profession\/publications\/college-bulletin\/january-2023\/blood-culture-pathway.html [Accessed 10 Mar 2025]."},{"key":"2026010906401282000_15.1.e003497.13","doi-asserted-by":"publisher","DOI":"10.1093\/cid\/ciy381"}],"container-title":["BMJ Open Quality"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjoq-2025-003497","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T14:40:19Z","timestamp":1767969619000},"score":1,"resource":{"primary":{"URL":"https:\/\/qir.bmj.com\/lookup\/doi\/10.1136\/bmjoq-2025-003497"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1,9]]},"published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1136\/bmjoq-2025-003497"],"URL":"https:\/\/doi.org\/10.1136\/bmjoq-2025-003497","relation":{},"ISSN":["2399-6641"],"issn-type":[{"value":"2399-6641","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]}}}