{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T15:10:53Z","timestamp":1778685053884,"version":"3.51.4"},"reference-count":16,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"unspecified","delay-in-days":42,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Qual"],"accepted":{"date-parts":[[2026,4,15]]},"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:p>At our institution, outpatient radioactive iodine-131 (\u00b9\u00b3\u00b9I) therapy requires coordination across multiple teams and is prone to inefficiencies. Patients and staff experienced process delays on the day of dose administration due to extended treatment times, inconsistent workflows and material waste. This project aimed to reduce overall process time (OPT) by 25% within 12 months while maintaining radiation safety and minimising material costs associated with room wrapping, a separate process involving the protection of treatment room surfaces from radioactive contamination.<\/jats:p>\n                  <jats:p>Workflow data were collected from 55\u2009patients treated between January 2022 and June 2024 to establish a baseline. Quality improvement methods using the Lean Six Sigma (Define, Measure, Analyse, Improve, Control) framework were applied to identify inefficiencies and implement changes through two sequential improvement cycles focused on standardising processes governing patient arrival, predosing and discharge. Wrapping workflow interventions simplified material use and standardised the wrapping order.<\/jats:p>\n                  <jats:p>After the first improvement cycle, average OPT decreased from 156.3 min to 114.2\u2009min (26.9% reduction from baseline). The proportion of patients with an OPT under 2\u2009hours increased from 9.1% to 61.9%. After the second improvement cycle, OPT further decreased to 103.0\u2009min (34.1% reduction from baseline), and 73.3% of patients were discharged within 2\u2009hours. Material costs per treatment decreased from $35.80 to $19.00 (46.9% reduction), with additional unquantified cost and time savings from procedure scheduling changes.<\/jats:p>\n                  <jats:p>The sequential application of Lean Six Sigma strategies significantly reduced process time and material costs in outpatient \u00b9\u00b3\u00b9I therapy without compromising radiation safety standards. These interventions demonstrate how structured quality improvement can enhance staff efficiency and resource use, providing a replicable model for other complex clinical workflows.<\/jats:p>","DOI":"10.1136\/bmjoq-2025-003903","type":"journal-article","created":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T14:20:57Z","timestamp":1778682057000},"page":"e003903","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Applying Lean Six Sigma to improve efficiency in outpatient iodine-131 therapy: reducing process time and material waste"],"prefix":"10.1136","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-7605-9188","authenticated-orcid":false,"given":"Shyam","family":"Jani","sequence":"first","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Murray","sequence":"additional","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dawn","family":"Kramer","sequence":"additional","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nitika","family":"Thawani","sequence":"additional","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aidnag","family":"Diaz","sequence":"additional","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2597-605X","authenticated-orcid":false,"given":"Stephen","family":"Sorensen","sequence":"additional","affiliation":[{"name":"Radiation Oncology, St Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,5,13]]},"reference":[{"key":"2026051307201524000_15.2.e003903.1","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2010.0403"},{"key":"2026051307201524000_15.2.e003903.2","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.prro.2025.03.006","article-title":"Quality and Safety Considerations for Radiopharmaceutical Therapy in the Radiation Oncology Environment: An ASTRO Safety White Paper","volume":"15","author":"Zoberi","year":"2025","journal-title":"Pract Radiat Oncol"},{"key":"2026051307201524000_15.2.e003903.3","first-page":"1580","article-title":"The frequency of vomiting after outpatient I-131 therapy (tx) in patients (pts) with well-differentiated thyroid cancer (WDTC)","volume":"51","author":"Khorjekar","year":"2010","journal-title":"J Nucl Med"},{"key":"2026051307201524000_15.2.e003903.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2010.10.001"},{"key":"2026051307201524000_15.2.e003903.5","doi-asserted-by":"crossref","first-page":"e571","DOI":"10.1016\/j.ijrobp.2012.01.063","article-title":"Quantitative assessment of workload and stressors in clinical radiation oncology","volume":"83","author":"Mazur","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2026051307201524000_15.2.e003903.6","first-page":"291","article-title":"Safety strategies in an academic radiation oncology department and recommendations for action","volume":"37","author":"Terezakis","year":"2011","journal-title":"Jt Comm J Qual Patient Saf"},{"key":"2026051307201524000_15.2.e003903.7","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.ijrobp.2014.01.024","article-title":"Workflow enhancement (WE) improves safety in radiation oncology: putting the WE and team together","volume":"89","author":"Chao","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2026051307201524000_15.2.e003903.8","doi-asserted-by":"crossref","first-page":"1910","DOI":"10.3390\/pr10101910","article-title":"Lean Six Sigma in Healthcare: A Systematic Literature Review on Motivations and Benefits","volume":"10","author":"McDermott","year":"2022","journal-title":"Processes (Basel)"},{"key":"2026051307201524000_15.2.e003903.9","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s00187-022-00336-9","article-title":"Success factors for lean six sigma projects in healthcare","volume":"33","author":"Sohal","year":"2022","journal-title":"J Manag Control"},{"key":"2026051307201524000_15.2.e003903.10","first-page":"E66","article-title":"The Statistical point of view of Quality: the Lean Six Sigma methodology","volume":"7","author":"Bertolaccini","year":"2015","journal-title":"J Thorac Dis"},{"key":"2026051307201524000_15.2.e003903.11","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1945-1474.2006.tb00596.x","article-title":"Lean six sigma in healthcare","volume":"28","author":"de Koning","year":"2006","journal-title":"J Healthc Qual"},{"key":"2026051307201524000_15.2.e003903.12","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.brachy.2016.08.001","article-title":"Process improvement for the safe delivery of multidisciplinary-executed treatments-A case in Y-90 microspheres therapy","volume":"16","author":"Cai","year":"2017","journal-title":"Brachytherapy"},{"key":"2026051307201524000_15.2.e003903.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.semradonc.2011.09.002"},{"key":"2026051307201524000_15.2.e003903.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2011.06.010"},{"key":"2026051307201524000_15.2.e003903.15","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.radonc.2018.02.019","article-title":"Applying Lean-Six-Sigma Methodology in radiotherapy: Lessons learned by the breast daily repositioning case","volume":"127","author":"Mancosu","year":"2018","journal-title":"Radiother Oncol"},{"key":"2026051307201524000_15.2.e003903.16","doi-asserted-by":"publisher","DOI":"10.1515\/reveh-2019-0003"}],"container-title":["BMJ Open Quality"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjoq-2025-003903","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T14:20:59Z","timestamp":1778682059000},"score":1,"resource":{"primary":{"URL":"https:\/\/qir.bmj.com\/lookup\/doi\/10.1136\/bmjoq-2025-003903"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,5,13]]},"published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1136\/bmjoq-2025-003903"],"URL":"https:\/\/doi.org\/10.1136\/bmjoq-2025-003903","relation":{},"ISSN":["2399-6641"],"issn-type":[{"value":"2399-6641","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}