{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T03:54:55Z","timestamp":1777953295830,"version":"3.51.4"},"reference-count":14,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:00:00Z","timestamp":1777852800000},"content-version":"unspecified","delay-in-days":33,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Qual"],"accepted":{"date-parts":[[2026,4,15]]},"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The application of intraoperative tourniquets is a fundamental component of distal radius fracture surgery, yet it carries a risk of significant complications. The British Orthopaedic Association (BOA) has published safety guidelines (BOA Standards for Trauma (BOAST)) to standardise practice, but adherence is often suboptimal. This quality improvement project aimed to evaluate and improve compliance with these guidelines in a real-world clinical setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A two-cycle retrospective audit was conducted at a major trauma centre in the UK. The first cycle (January to April 2023, n=34) established baseline compliance with seven key BOAST documentation standards. Following this, a multifaceted intervention was implemented, including staff education, the introduction of a standardised checklist and the placement of visual reminders in operating theatres. A re-audit was then conducted (May to June 2024, n=63) to measure the impact of these interventions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Baseline documentation compliance was extremely low, with only tourniquet pressure recorded in 20.5% (7\/34) and tourniquet time documented in 55.9% (19\/34). Following the interventions, documentation of tourniquet pressure increased to 59.0% (37\/63) and tourniquet site, padding, compressive exsanguination, skin condition, tourniquet size and tourniquet time showed modest improvements. Overall compliance, however, remained below optimal levels.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>A targeted quality improvement initiative combining education and practical tools can lead to meaningful improvements in adherence to tourniquet safety guidelines. Despite these gains, persistent documentation gaps highlight the need for more robust, system-level solutions, such as integration into electronic health records, to ensure sustained compliance and enhance patient safety.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjoq-2025-003956","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T14:55:12Z","timestamp":1777906512000},"page":"e003956","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project"],"prefix":"10.1136","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7376-4963","authenticated-orcid":false,"given":"Mahmoud","family":"Mersal","sequence":"first","affiliation":[{"name":"University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samer","family":"Sarofeen","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6463-0752","authenticated-orcid":false,"given":"Osama","family":"Embaby","sequence":"additional","affiliation":[{"name":"Orthopaedic Surgery, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Shammout","sequence":"additional","affiliation":[{"name":"University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ciara","family":"O\u2019Sullivan","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chloe","family":"Lawrence","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sitaram","family":"Giri","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,5,4]]},"reference":[{"key":"2026050407550874000_15.2.e003956.1","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5413.98824"},{"key":"2026050407550874000_15.2.e003956.2","doi-asserted-by":"publisher","DOI":"10.1093\/bjaceaccp\/mkp002"},{"key":"2026050407550874000_15.2.e003956.3","doi-asserted-by":"crossref","DOI":"10.5812\/ircmj.9588","article-title":"Tourniquet in surgery of the limbs: a review of history, types and complications","volume":"17","author":"Saied","year":"2015","journal-title":"Iran Red Crescent Med J"},{"key":"2026050407550874000_15.2.e003956.4","doi-asserted-by":"crossref","DOI":"10.1186\/s42490-020-00041-5","article-title":"Tourniquet-induced nerve compression injuries are caused by high pressure levels and gradients - a review of the evidence to guide safe surgical, pre-hospital and blood flow restriction usage","volume":"2","author":"Masri","year":"2020","journal-title":"BMC Biomed Eng"},{"key":"2026050407550874000_15.2.e003956.5","doi-asserted-by":"crossref","DOI":"10.1186\/s13017-025-00625-3","article-title":"Tourniquet-related complications in extremity injuries: a scoping review of the literature","volume":"20","author":"Xacur-Trabulce","year":"2025","journal-title":"World J Emerg Surg"},{"key":"2026050407550874000_15.2.e003956.6","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1186\/s13018-024-05176-y","article-title":"Low tourniquet pressure has less impact on lower extremity nerve innervation: comparison of different tourniquet pressures used with intraoperative neuromonitoring with a randomized controlled study","volume":"19","author":"Y\u0131ld\u0131r\u0131m","year":"2024","journal-title":"J Orthop Surg Res"},{"key":"2026050407550874000_15.2.e003956.7","unstructured":"British Orthopaedic Association . Boast - the safe use of intraoperative tourniquets. 2021. Available: https:\/\/www.boa.ac.uk\/resource\/boast-the-safe-use-of-intraoperative-tourniquets.html"},{"key":"2026050407550874000_15.2.e003956.8","article-title":"Embracing Digital Transformation: A Three-Cycle Audit on Improving Intraoperative Tourniquet Documentation Following BOAST (British Orthopaedic Association Standards for Trauma) Guidelines","volume":"16","author":"Kafagi","year":"2024","journal-title":"Cureus"},{"key":"2026050407550874000_15.2.e003956.9","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1308\/rcsann.2023.0072","article-title":"Introducing a new proforma for the safe use of intraoperative tourniquets in orthopaedic surgery","volume":"107","author":"Garner","year":"2025","journal-title":"Ann R Coll Surg Engl"},{"key":"2026050407550874000_15.2.e003956.10","article-title":"Management of tourniquet-related nerve injury (TRNI): a systematic review","volume":"14","author":"Chang","year":"2022","journal-title":"Cureus"},{"key":"2026050407550874000_15.2.e003956.11","doi-asserted-by":"crossref","DOI":"10.1186\/s12893-024-02579-w","article-title":"Summary of the best evidence for the safe use of pneumatic tourniquet in limb surgery","volume":"24","author":"Liu","year":"2024","journal-title":"BMC Surg"},{"key":"2026050407550874000_15.2.e003956.12","doi-asserted-by":"publisher","DOI":"10.1136\/bmjqs-2015-004411"},{"key":"2026050407550874000_15.2.e003956.13","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.mpsur.2023.08.008","article-title":"Tourniquet use in trauma and orthopaedics, how and when: current evidence","volume":"41","author":"Hamad","year":"2023","journal-title":"Surgery (Oxford)"},{"key":"2026050407550874000_15.2.e003956.14","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1186\/s12891-023-06979-6","article-title":"The effects of tourniquet use on blood loss and perioperative complications in total knee arthroplasty","volume":"24","author":"Tan","year":"2023","journal-title":"BMC Musculoskelet Disord"}],"container-title":["BMJ Open Quality"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjoq-2025-003956","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T14:55:15Z","timestamp":1777906515000},"score":1,"resource":{"primary":{"URL":"https:\/\/qir.bmj.com\/lookup\/doi\/10.1136\/bmjoq-2025-003956"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":14,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,5,4]]},"published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1136\/bmjoq-2025-003956"],"URL":"https:\/\/doi.org\/10.1136\/bmjoq-2025-003956","relation":{},"ISSN":["2399-6641"],"issn-type":[{"value":"2399-6641","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}