{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T12:55:00Z","timestamp":1773924900505,"version":"3.50.1"},"reference-count":37,"publisher":"BMJ","issue":"4","funder":[{"DOI":"10.13039\/501100004489","name":"Mitacs","doi-asserted-by":"publisher","award":["021853"],"award-info":[{"award-number":["021853"]}],"id":[{"id":"10.13039\/501100004489","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100025250","name":"Vancouver Coastal Health","doi-asserted-by":"crossref","award":["021853"],"award-info":[{"award-number":["021853"]}],"id":[{"id":"10.13039\/501100025250","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Qual Saf"],"accepted":{"date-parts":[[2025,11,15]]},"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Intraoperative hypothermia can lead to adverse clinical outcomes and avoidable financial and environmental costs. Environmentally preferable warming practices have been identified, including using reusable resistive blankets, extending the life cycle of forced air warming (FAW) garments and minimising flannel blanket use. This study integrates existing environmental data with best practices and quality improvement methodology to develop an optimised patient warming pathway (OPWP). This pathway was adapted to our local context, implemented and evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The OPWP was developed using a scoping review, prior environmental impact assessment and root cause analysis. It was tailored to the workflows, patient population and warming practices at a tertiary care hospital and implemented using a multifaceted approach encompassing nine PDSA (Plan-Do-Study-Act) cycles. Major interventions included expanding pre-warming criteria to meet best practice guidelines, preserving the FAW Flex Gown, staff education and training, behaviourally informed strategies, gamification and policy development. Pre-intervention and post-intervention audits assessed environmental and financial savings, incidence of hypothermia and patient-reported outcomes (PROs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The OPWP recommends preferential use of the resistive blanket for intraoperative warming, preservation of the Flex Gown for postoperative use when warming with FAW and minimising flannel blanket use. A modified pathway was implemented using FAW with preservation of a single Flex Gown throughout the perioperative journey. From pre-intervention (N=51) to post-intervention (N=64), flannel blanket use decreased from an average of 6 to 3 per patient (p&lt;0.01). Active warming increased from 55% to 80% (p=0.04) preoperatively and from 0% to 55% (p&lt;0.01) postoperatively. There was no significant change in the incidence of hypothermia (18% to 15%, p=0.77) and PROs remained favourable. Implementation of this pathway could lead to annual environmental savings of 940\u2009339\u2009kg of carbon dioxide equivalents and cost savings of $C117\u2009978.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study demonstrates the successful implementation of an evidence-based and environmentally sustainable perioperative warming pathway to achieve low-carbon, high-quality patient care.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjqs-2025-018638","type":"journal-article","created":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T18:20:18Z","timestamp":1770661218000},"page":"275-287","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Implementing and evaluating a low-carbon, high-quality perioperative patient warming pathway"],"prefix":"10.1136","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-6142-757X","authenticated-orcid":false,"given":"Karina","family":"Spoyalo","sequence":"first","affiliation":[{"name":"Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thais Ayres","family":"Rebello","sequence":"additional","affiliation":[{"name":"School of Engineering, University of British Columbia, Kelowna, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Schwarz","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gyan","family":"Chhipi Shrestha","sequence":"additional","affiliation":[{"name":"School of Engineering, University of British Columbia, Kelowna, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kasun","family":"Hewage","sequence":"additional","affiliation":[{"name":"School of Engineering, University of British Columbia, Kelowna, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rehan","family":"Sadiq","sequence":"additional","affiliation":[{"name":"School of Engineering, University of British Columbia, Kelowna, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shawn E","family":"Mondoux","sequence":"additional","affiliation":[{"name":"Department of Medicine, McMaster University, Hamilton, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew","family":"Walker","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Pharmacology & Therapeutics, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kelly","family":"Mayson","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Pharmacology & Therapeutics, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6836-0000","authenticated-orcid":false,"given":"Andrea J","family":"MacNeill","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2026,2,9]]},"reference":[{"key":"2026031902050970000_35.4.275.1","unstructured":"World Health Organization . COP26 health programme. Geneva: World Health Organization; 2025. Available: https:\/\/www.who.int\/initiatives\/alliance-for-transformative-action-on-climate-and-health\/cop26-health-programme"},{"key":"2026031902050970000_35.4.275.2","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0157014","article-title":"Environmental Impacts of the U.S. Health Care System and Effects on Public Health","volume":"11","author":"Eckelman","year":"2016","journal-title":"PLoS One"},{"key":"2026031902050970000_35.4.275.3","doi-asserted-by":"publisher","DOI":"10.2105\/AJPH.2017.303846"},{"key":"2026031902050970000_35.4.275.4","doi-asserted-by":"publisher","DOI":"10.1002\/hpm.3616"},{"key":"2026031902050970000_35.4.275.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcjq.2023.02.006"},{"key":"2026031902050970000_35.4.275.6","doi-asserted-by":"crossref","DOI":"10.1136\/bmj-2023-076957","article-title":"Health systems and environmental sustainability: updating frameworks for a new era","volume":"385","author":"Padget","year":"2024","journal-title":"BMJ"},{"key":"2026031902050970000_35.4.275.7","doi-asserted-by":"crossref","DOI":"10.1093\/intqhc\/mzac066","article-title":"Environmental sustainability and quality care: Not one without the other","volume":"34","author":"Putnis","year":"2022","journal-title":"Int J Qual Health Care"},{"key":"2026031902050970000_35.4.275.8","doi-asserted-by":"crossref","first-page":"e66","DOI":"10.1016\/S2542-5196(21)00005-X","article-title":"Planetary health care: a framework for sustainable health systems","volume":"5","author":"MacNeill","year":"2021","journal-title":"Lancet Planet Health"},{"key":"2026031902050970000_35.4.275.9","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0309417","article-title":"Metrics used in quality improvement publications addressing environmental sustainability in healthcare: A scoping review protocol","volume":"19","author":"Sue-Chue-Lam","year":"2024","journal-title":"PLoS One"},{"key":"2026031902050970000_35.4.275.10","unstructured":"National Institute for Health and Care Excellence . Hypothermia: prevention and management in adults having surgery. 2016. Available: www.nice.org.uk\/guidance\/cg65 [Accessed 23 Sep 2023]."},{"key":"2026031902050970000_35.4.275.11","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/S0001-2092(06)63920-3","article-title":"Effects of comfort warming on preoperative patients","volume":"84","author":"Wagner","year":"2006","journal-title":"AORN J"},{"key":"2026031902050970000_35.4.275.12","doi-asserted-by":"publisher","DOI":"10.1016\/S0001-2092(06)60120-8"},{"key":"2026031902050970000_35.4.275.13","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S0140-6736(96)90466-3","article-title":"Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty","volume":"347","author":"Schmied","year":"1996","journal-title":"The Lancet"},{"key":"2026031902050970000_35.4.275.14","doi-asserted-by":"publisher","DOI":"10.1097\/01.anes.0000296719.73450.52"},{"key":"2026031902050970000_35.4.275.15","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1997.03540380041029"},{"key":"2026031902050970000_35.4.275.16","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/00008506-199610000-00013","article-title":"Perioperative normothermia to reduce the incidence of surgical wound infection and shorten hospitalization","volume":"8","year":"1996","journal-title":"J Neurosurg Anesthesiol"},{"key":"2026031902050970000_35.4.275.17","doi-asserted-by":"publisher","DOI":"10.1016\/S0001-2092(06)61744-4"},{"key":"2026031902050970000_35.4.275.18","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1002\/aorn.13327","article-title":"The Role of Perioperative Hypothermia in the Development of Surgical Site Infection: A Systematic Review","volume":"113","author":"\u00d6ner Cengiz","year":"2021","journal-title":"AORN J"},{"key":"2026031902050970000_35.4.275.19","doi-asserted-by":"crossref","first-page":"2294","DOI":"10.1111\/jan.13010","article-title":"Meta-analysis: effectiveness of forced-air warming for prevention of perioperative hypothermia in surgical patients","volume":"72","author":"Nieh","year":"2016","journal-title":"J Adv Nurs"},{"key":"2026031902050970000_35.4.275.20","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1111\/j.1365-2648.2010.05312.x","article-title":"Effectiveness of cutaneous warming systems on temperature control: meta-analysis","volume":"66","author":"Galv\u00e3o","year":"2010","journal-title":"J Adv Nurs"},{"key":"2026031902050970000_35.4.275.21","unstructured":"Rebello TA , Spoyalo K , Chhipi-Shrestha G , et al . A clinical life cycle sustainability assessment of peri-operative patient warming. Br J Anaesth 2025."},{"key":"2026031902050970000_35.4.275.22","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1177\/0310057X231212211","article-title":"Exploring anaesthetists\u2019 views on the carbon footprint of anaesthesia and identifying opportunities and challenges for reducing its impact on the environment","volume":"52","author":"Breth-Petersen","year":"2024","journal-title":"Anaesth Intensive Care"},{"key":"2026031902050970000_35.4.275.23","unstructured":"Institute for Safe Medication Practices Canada . Hierarchy of effectiveness. Toronto: ISMP Canada; 2025. Available: https:\/\/ismpcanada.ca\/resource\/hierarchy-of-effectiveness\/"},{"key":"2026031902050970000_35.4.275.24","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000010528","article-title":"Association between perioperative hypothermia and patient outcomes after thoracic surgery: A single center retrospective analysis","volume":"97","author":"Emmert","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"2026031902050970000_35.4.275.25","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.ijsu.2015.06.079","article-title":"Risk factors for hypothermia in patients under general anesthesia: Is there a drawback of laminar airflow operating rooms? A prospective cohort study","volume":"21","author":"Yang","year":"2015","journal-title":"Int J Surg"},{"key":"2026031902050970000_35.4.275.26","doi-asserted-by":"crossref","DOI":"10.1136\/bmjoq-2020-001132","article-title":"Using a comprehensive audit to identify local context prior to care bundle design and implementation for inadvertent perioperative hypothermia in colorectal surgery","volume":"10","author":"Tanner","year":"2021","journal-title":"BMJ Open Qual"},{"key":"2026031902050970000_35.4.275.27","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1111\/jocn.14171","article-title":"Effect of a thermal care bundle on the prevention, detection and treatment of perioperative inadvertent hypothermia","volume":"27","author":"Duff","year":"2018","journal-title":"J Clin Nurs"},{"key":"2026031902050970000_35.4.275.28","unstructured":"Davey S , Reilly T , Newton M , et al . The reproducibility and validity of visual analogue scales (VAS) that assess thermal perceptions in stable and dynamic, asymmetric environments. Environmental Ergonomics XII 2007."},{"key":"2026031902050970000_35.4.275.29","doi-asserted-by":"publisher","DOI":"10.1111\/j.1552-6909.2006.00052.x"},{"key":"2026031902050970000_35.4.275.30","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1213\/00000539-200202000-00034","article-title":"Active Warming During Cesarean Delivery","volume":"94","author":"Horn","year":"2002","journal-title":"Anesthesia & Analgesia"},{"key":"2026031902050970000_35.4.275.31","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.colegn.2019.10.003","article-title":"Costs of inadvertent perioperative hypothermia in Australia: A cost-of-illness study","volume":"27","author":"Ralph","year":"2020","journal-title":"Collegian"},{"key":"2026031902050970000_35.4.275.32","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2015-009509","article-title":"Temperature measurements with a temporal scanner: systematic review and meta-analysis","volume":"6","author":"Geijer","year":"2016","journal-title":"BMJ Open"},{"key":"2026031902050970000_35.4.275.33","doi-asserted-by":"publisher","DOI":"10.1136\/bmjebm-2023-112707"},{"key":"2026031902050970000_35.4.275.34","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jopan.2010.01.008","article-title":"Comfort, satisfaction, and anxiolysis in surgical patients using a patient-adjustable comfort warming system: a prospective randomized clinical trial","volume":"25","author":"O\u2019Brien","year":"2010","journal-title":"J Perianesth Nurs"},{"key":"2026031902050970000_35.4.275.35","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1213\/ANE.0000000000005145","article-title":"Effect of Perioperative Active Body Surface Warming Systems on Analgesic and Clinical Outcomes: A Systematic Review and Meta-analysis of Randomized Controlled Trials","volume":"131","author":"Balki","year":"2020","journal-title":"Anesthesia & Analgesia"},{"key":"2026031902050970000_35.4.275.36","article-title":"Active body surface warming systems for preventing complications caused by inadvertent perioperative hypothermia in adults","volume":"4","author":"Madrid","year":"2016","journal-title":"Cochrane Database Syst Rev"},{"key":"2026031902050970000_35.4.275.37","doi-asserted-by":"publisher","DOI":"10.1016\/j.aorn.2010.06.015"}],"container-title":["BMJ Quality &amp; Safety"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjqs-2025-018638","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T09:05:52Z","timestamp":1773911152000},"score":1,"resource":{"primary":{"URL":"https:\/\/qualitysafety.bmj.com\/lookup\/doi\/10.1136\/bmjqs-2025-018638"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,9]]},"references-count":37,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,3,19]]},"published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1136\/bmjqs-2025-018638"],"URL":"https:\/\/doi.org\/10.1136\/bmjqs-2025-018638","relation":{},"ISSN":["2044-5415","2044-5423"],"issn-type":[{"value":"2044-5415","type":"print"},{"value":"2044-5423","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,9]]}}}