{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T13:21:31Z","timestamp":1787318491499,"version":"build-2736575974"},"reference-count":25,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2021,5,27]],"date-time":"2021-05-27T00:00:00Z","timestamp":1622073600000},"content-version":"unspecified","delay-in-days":26,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Resp Res"],"accepted":{"date-parts":[[2021,5,11]]},"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Trending venous blood gases (VBGs) has been suggested as an alternative to arterial blood gases (ABGs) in patients with respiratory failure, but there are limits to its utility. The aim of this study was to compare the trending of venous carbon dioxide partial pressure (pCO\n                      <jats:sub>2<\/jats:sub>\n                      ) (pCO\n                      <jats:sub>2<\/jats:sub>\n                      v) with mathematically arterialised pCO\n                      <jats:sub>2<\/jats:sub>\n                      (pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca) and to further evaluate whether pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca follows change in arterial pCO\n                      <jats:sub>2<\/jats:sub>\n                      (pCO\n                      <jats:sub>2<\/jats:sub>\n                      a) more accurately.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      We analysed two data sets. The first was a retrospective study of patients with respiratory failure admitted to the intensive care unit. Venous samples were mathematically arterialised using the vTAC method. The change in pCO\n                      <jats:sub>2<\/jats:sub>\n                      between two consecutive samples (\u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      ) for pCO\n                      <jats:sub>2<\/jats:sub>\n                      v was compared with the change in calculated pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca values. In the second data set taken from previously published work, we analysed 82 trend points (difference between consecutive samples) for change in pCO\n                      <jats:sub>2<\/jats:sub>\n                      . There were pCO\n                      <jats:sub>2<\/jats:sub>\n                      v, pCO\n                      <jats:sub>2<\/jats:sub>\n                      a and pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca values for each trend point. The primary outcome measures were the 95% limits of agreement (LOAs) between different sampling methods for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In the first data set, 46 patients had 203 VBG results giving 157 trend points for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      analysis. The 95% LOAs for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca and \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      v were \u22129.28 to 11.12 mm Hg.\n                    <\/jats:p>\n                    <jats:p>\n                      In the second data set, 95% LOAs for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      were \u22129.46 to 9.48 mm Hg for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      a and \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      v, \u22128.94 to 8.58 mm Hg for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca and \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      v, and \u22124.54 to 4.91 mm Hg for \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      a and \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      This study suggests that trending pCO\n                      <jats:sub>2<\/jats:sub>\n                      v is not an accurate way to trend pCO\n                      <jats:sub>2<\/jats:sub>\n                      a in patients with respiratory failure. \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca via vTAC trended differently to \u0394pCO\n                      <jats:sub>2<\/jats:sub>\n                      v. Our data suggest pCO\n                      <jats:sub>2<\/jats:sub>\n                      ca more accurately trends pCO\n                      <jats:sub>2<\/jats:sub>\n                      a.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjresp-2021-000896","type":"journal-article","created":{"date-parts":[[2021,5,28]],"date-time":"2021-05-28T13:51:25Z","timestamp":1622209885000},"page":"e000896","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":6,"title":["Trending peripheral venous PCO\n                    <sub>2<\/sub>\n                    in patients with respiratory failure using mathematically arterialised venous blood gas samples"],"prefix":"10.1136","volume":"8","author":[{"given":"Merle","family":"Weber","sequence":"first","affiliation":[{"name":"Intensive Care Unit, Hawke's Bay District Health Board, Hastings, Hawke's Bay, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9992-8252","authenticated-orcid":false,"given":"Grant","family":"Cave","sequence":"additional","affiliation":[{"name":"Intensive Care Unit, Hawke's Bay District Health Board, Hastings, Hawke's Bay, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2021,5,28]]},"reference":[{"key":"2025083109374667000_8.1.e000896.1","doi-asserted-by":"crossref","first-page":"305","DOI":"10.2147\/OAEM.S228420","article-title":"Can venous blood gas be used as an alternative to arterial blood gas in intubated patients at admission to the emergency department? A retrospective study","volume":"11","author":"Sch\u00fctz","year":"2019","journal-title":"Open Access Emerg Med"},{"key":"2025083109374667000_8.1.e000896.2","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2006.035915"},{"key":"2025083109374667000_8.1.e000896.3","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2007.046979"},{"key":"2025083109374667000_8.1.e000896.4","doi-asserted-by":"publisher","DOI":"10.1097\/MEJ.0b013e328335622a"},{"key":"2025083109374667000_8.1.e000896.5","doi-asserted-by":"publisher","DOI":"10.1111\/1742-6723.12066"},{"key":"2025083109374667000_8.1.e000896.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2011.06.011"},{"key":"2025083109374667000_8.1.e000896.7","doi-asserted-by":"publisher","DOI":"10.1111\/resp.12225"},{"key":"2025083109374667000_8.1.e000896.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jemermed.2004.10.017"},{"key":"2025083109374667000_8.1.e000896.9","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.jemermed.2008.04.014","article-title":"Point-Of-Care bedside gas analyzer: limited use of venous PCO2 in emergency patients","volume":"41","author":"Ibrahim","year":"2011","journal-title":"J Emerg Med"},{"key":"2025083109374667000_8.1.e000896.10","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1177\/0885066616652597","article-title":"Correlation of venous blood gas and pulse oximetry with arterial blood gas in the undifferentiated critically ill patient","volume":"33","author":"Zeserson","year":"2018","journal-title":"J Intensive Care Med"},{"key":"2025083109374667000_8.1.e000896.11","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1017\/S1481803500006011","article-title":"Can peripheral venous blood gases replace arterial blood gases in emergency department patients?","volume":"4","author":"Rang","year":"2002","journal-title":"CJEM"},{"key":"2025083109374667000_8.1.e000896.12","first-page":"69","article-title":"Can a change in pH and PCO2 be used to monitor progress in patients undergoing noninvasive ventilation? A prospective cohort study","volume":"21","author":"Kelly","year":"2014","journal-title":"Eur J Emerg Med"},{"key":"2025083109374667000_8.1.e000896.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2005.10.003"},{"key":"2025083109374667000_8.1.e000896.14","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1007\/s10877-018-0197-1","article-title":"Mathematical arterialisation of peripheral venous blood gas for obtainment of arterial blood gas values: a methodological validation study in the clinical setting","volume":"33","author":"Lumholdt","year":"2019","journal-title":"J Clin Monit Comput"},{"key":"2025083109374667000_8.1.e000896.15","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2007.052571"},{"key":"2025083109374667000_8.1.e000896.16","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00140408"},{"key":"2025083109374667000_8.1.e000896.17","doi-asserted-by":"publisher","DOI":"10.1097\/MEJ.0b013e32834de4c6"},{"key":"2025083109374667000_8.1.e000896.18","doi-asserted-by":"crossref","first-page":"2149-54","DOI":"10.1515\/cclm-2012-0233","article-title":"Calculating acid-base and oxygenation status during COPD exacerbation using mathematically arterialised venous blood","volume":"50","author":"Rees","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"2025083109374667000_8.1.e000896.19","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0215413","article-title":"Calculated arterial blood gas values from a venous sample and pulse oximetry: clinical validation","volume":"14","author":"Ekstr\u00f6m","year":"2019","journal-title":"PLoS One"},{"key":"2025083109374667000_8.1.e000896.20","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2021.106022","article-title":"Comparison of two methods for converting central venous values of acid-base status to arterial values in critically ill patients","volume":"203","author":"Shastri","year":"2021","journal-title":"Comput Methods Programs Biomed"},{"key":"2025083109374667000_8.1.e000896.21","unstructured":"Bland M . How can I decide the sample size for a study of agreement between two methods of measurement? Available: https:\/\/www-users.york.ac.uk\/~mb55\/meas\/sizemeth.htm"},{"key":"2025083109374667000_8.1.e000896.22","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2015-205572"},{"key":"2025083109374667000_8.1.e000896.23","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2007.091223"},{"key":"2025083109374667000_8.1.e000896.24","doi-asserted-by":"crossref","DOI":"10.1186\/s13049-021-00848-8","article-title":"Is venous blood a more reliable description of acid-base state following simulated hypo- and hyperventilation?","volume":"29","author":"Shastri","year":"2021","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"2025083109374667000_8.1.e000896.25","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1159\/000512214","article-title":"Evaluation of mathematical arterialization of venous blood in intensive care and pulmonary ward patients","volume":"100","author":"Thomsen","year":"2021","journal-title":"Respiration"}],"container-title":["BMJ Open Respiratory Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjresp-2021-000896","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,31]],"date-time":"2025-08-31T16:37:52Z","timestamp":1756658272000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopenrespres.bmj.com\/lookup\/doi\/10.1136\/bmjresp-2021-000896"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,5,28]]},"published-print":{"date-parts":[[2021,5]]}},"alternative-id":["10.1136\/bmjresp-2021-000896"],"URL":"https:\/\/doi.org\/10.1136\/bmjresp-2021-000896","relation":{},"ISSN":["2052-4439"],"issn-type":[{"value":"2052-4439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5]]}}}