{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T23:55:29Z","timestamp":1783727729615,"version":"3.55.0"},"reference-count":52,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,7,21]],"date-time":"2025-07-21T00:00:00Z","timestamp":1753056000000},"content-version":"unspecified","delay-in-days":20,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100016545","name":"Roche Diagnostics","doi-asserted-by":"publisher","award":["9110193179"],"award-info":[{"award-number":["9110193179"]}],"id":[{"id":"10.13039\/100016545","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100022617","name":"Fisher and Paykel Healthcare","doi-asserted-by":"publisher","award":["NA"],"award-info":[{"award-number":["NA"]}],"id":[{"id":"10.13039\/501100022617","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Resp Res"],"accepted":{"date-parts":[[2025,7,3]]},"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Liberation from invasive mechanical ventilation is a milestone in critical care, but approaches vary. This survey aimed to describe current ventilator liberation practices, relate them to available evidence, and identify areas for improvement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A survey was performed among Dutch intensive care unit (ICU) sites. The survey evaluated practice in seven domains of ventilator liberation: protocol availability, transition from controlled to assisted ventilation, spontaneous breathing trials (SBT), cuff-leak test, postextubation support, weaning failure and tracheostomised weaning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The survey response rate was 93% (132\/142), representing 97% (69\/71) of Dutch ICUs. Protocols for postextubation support and weaning failure were available in less than half of the ICUs (44% and 49%, respectively). The transition from controlled to assisted ventilation is regularly evaluated daily in 78% of ICUs. Assisted ventilation tolerance is mainly assessed by clinical signs, respiratory parameters and non-invasive manoeuvres that assess respiratory drive (P\n                      <jats:sub>0.1<\/jats:sub>\n                      ). SBTs are regularly performed in 58% of ICUs, using one or more of the following methods: T-piece (52%), pressure support+positive end expiratory pressure (32%) and continuous positive airway pressure (28%). Cuff-leak tests are seldom performed (1.4%), predominantly in cases of intubation for upper-airway obstruction (92%). Postextubation respiratory support with high-flow nasal oxygen or non-invasive ventilation is used at least as often with therapeutic (43%\/13%) rather than preventive (35%\/4%) of facilitative intent (29%\/3%). Delirium screening (87%) and reconsidering sedation (84%) are frequently assessed in case of weaning failure. Regular use of closed-loop ventilation is reported in a minority of ICUs throughout the process of ventilator liberation (3\u20139%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Various aspects of ventilator liberation practices show only limited alignment with existing guidelines. The results of this survey pinpoint areas to prioritise in guideline and practice improvement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjresp-2024-002868","type":"journal-article","created":{"date-parts":[[2025,7,22]],"date-time":"2025-07-22T05:30:11Z","timestamp":1753162211000},"page":"e002868","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":3,"title":["Liberation from invasive mechanical ventilation: a nationwide survey among intensive care units in the Netherlands"],"prefix":"10.1136","volume":"12","clinical-trial-number":[{"clinical-trial-number":"nct05686850","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Carline N L","family":"Groenland","sequence":"first","affiliation":[{"name":"Intensive Care, Franciscus Gasthuis en Vlietland, Rotterdam, The Netherlands"},{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthijs L","family":"Janssen","sequence":"additional","affiliation":[{"name":"Intensive Care, Franciscus Gasthuis en Vlietland, Rotterdam, The Netherlands"},{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kim S","family":"van den Bosch","sequence":"additional","affiliation":[{"name":"Intensive Care, Franciscus Gasthuis en Vlietland, Rotterdam, The Netherlands"},{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivan J M","family":"Baggen","sequence":"additional","affiliation":[{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leo","family":"Heunks","sequence":"additional","affiliation":[{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"},{"name":"Intensive Care, Radboudumc, Nijmegen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henrik","family":"Endeman","sequence":"additional","affiliation":[{"name":"Adult Intensive Care, Erasmus MC Medische Faculteit Rotterdam, Rotterdam, The Netherlands"},{"name":"Intensive Care, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2868-0920","authenticated-orcid":false,"given":"Evert-Jan","family":"Wils","sequence":"additional","affiliation":[{"name":"Intensive Care, Franciscus Gasthuis en Vlietland, Rotterdam, The Netherlands"},{"name":"Intensive Care, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,7,21]]},"reference":[{"key":"2026010701504576000_12.1.e002868.1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00010206"},{"key":"2026010701504576000_12.1.e002868.2","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0000000000001091"},{"key":"2026010701504576000_12.1.e002868.3","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/ALN.0000000000000874","article-title":"Acquired Muscle Weakness in the Surgical Intensive Care Unit: Nosology, Epidemiology, Diagnosis, and Prevention","volume":"124","author":"Farhan","year":"2016","journal-title":"Anesthesiology"},{"key":"2026010701504576000_12.1.e002868.4","unstructured":"Provost KA , El-Solh AA . Complications associated with mechanical ventilation. New York, NY: McGraw-Hill Education, 2012."},{"key":"2026010701504576000_12.1.e002868.5","doi-asserted-by":"crossref","DOI":"10.1186\/cc10117","article-title":"Prolonged mechanical ventilation in critically ill patients: epidemiology, outcomes and modelling the potential cost consequences of establishing a regional weaning unit","volume":"15","author":"Lone","year":"2011","journal-title":"Crit Care"},{"key":"2026010701504576000_12.1.e002868.6","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0B013E31816536F7"},{"key":"2026010701504576000_12.1.e002868.7","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1513\/AnnalsATS.201705-410OC","article-title":"International Practice Variation in Weaning Critically Ill Adults from Invasive Mechanical Ventilation","volume":"15","author":"Burns","year":"2018","journal-title":"Ann Am Thorac Soc"},{"key":"2026010701504576000_12.1.e002868.8","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1164\/rccm.201610-2075ST","article-title":"An Official American Thoracic Society\/American College of Chest Physicians Clinical Practice Guideline: Liberation from Mechanical Ventilation in Critically Ill Adults. Rehabilitation Protocols, Ventilator Liberation Protocols, and Cuff Leak Tests","volume":"195","author":"Girard","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"2026010701504576000_12.1.e002868.9","doi-asserted-by":"publisher","DOI":"10.1016\/S2213-2600(22)00449-0"},{"key":"2026010701504576000_12.1.e002868.10","unstructured":"Heunks L . Herziene richtlijn ontwenning van de beademing voor volwassen pati\u00ebnten op een intensive care. 2018."},{"key":"2026010701504576000_12.1.e002868.11","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/S2213-2600(22)00502-1","article-title":"Weaning from mechanical ventilation in intensive care units: a call for new international consensus guidelines","volume":"11","author":"Jaber","year":"2023","journal-title":"Lancet Respir Med"},{"key":"2026010701504576000_12.1.e002868.12","unstructured":"Kwaliteitsstandaard intensive care. 2016. Available: https:\/\/www.nvic.nl\/richtlijn\/organisatie-van-intensive-care-kwaliteitsstandaard-2016\/ [Accessed 4 Jul 2024]."},{"key":"2026010701504576000_12.1.e002868.13","unstructured":"Dutch National Intensive Care Foundation . Available: https:\/\/www.stichting-nice.nl\/ [Accessed 4 Jul 2024]."},{"key":"2026010701504576000_12.1.e002868.14","unstructured":"Dutch Society of Intensive Care . Available: https:\/\/www.nvic.nl\/"},{"key":"2026010701504576000_12.1.e002868.15","doi-asserted-by":"publisher","DOI":"10.1007\/s11606-021-06737-1"},{"key":"2026010701504576000_12.1.e002868.16","doi-asserted-by":"publisher","DOI":"10.1503\/cmaj.080372"},{"key":"2026010701504576000_12.1.e002868.17","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1016\/S2213-2600(18)30375-8","article-title":"Ventilatory support after extubation in critically ill patients","volume":"6","author":"Maggiore","year":"2018","journal-title":"Lancet Respir Med"},{"key":"2026010701504576000_12.1.e002868.18","doi-asserted-by":"publisher","DOI":"10.1186\/cc9296"},{"key":"2026010701504576000_12.1.e002868.19","first-page":"1","article-title":"The transition phase between controlled mechanical ventilation and weaning is our next great cause","volume":"31","author":"Demoule","year":"2025","journal-title":"Curr Opin Crit Care"},{"key":"2026010701504576000_12.1.e002868.20","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1111\/aas.14317","article-title":"A survey of preferences for respiratory support in the intensive care unit for patients with acute hypoxaemic respiratory failure","volume":"67","author":"Aslam","year":"2023","journal-title":"Acta Anaesthesiol Scand"},{"key":"2026010701504576000_12.1.e002868.21","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201605-1081cp"},{"key":"2026010701504576000_12.1.e002868.22","doi-asserted-by":"crossref","first-page":"2329","DOI":"10.1001\/jama.2020.6825","article-title":"Management of COVID-19 Respiratory Distress","volume":"323","author":"Marini","year":"2020","journal-title":"JAMA"},{"key":"2026010701504576000_12.1.e002868.23","doi-asserted-by":"crossref","DOI":"10.1186\/s13613-020-00692-6","article-title":"Caution about early intubation and mechanical ventilation in COVID-19","volume":"10","author":"Tobin","year":"2020","journal-title":"Ann Intensive Care"},{"key":"2026010701504576000_12.1.e002868.24","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/ALN.0000000000004467","article-title":"Performance of Noninvasive Airway Occlusion Maneuvers to Assess Lung Stress and Diaphragm Effort in Mechanically Ventilated Critically Ill Patients","volume":"138","author":"de Vries","year":"2023","journal-title":"Anesthesiology"},{"key":"2026010701504576000_12.1.e002868.25","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1007\/s00134-018-5045-8","article-title":"The airway occlusion pressure (P0.1) to monitor respiratory drive during mechanical ventilation: increasing awareness of a not-so-new problem","volume":"44","author":"Telias","year":"2018","journal-title":"Intensive Care Med"},{"key":"2026010701504576000_12.1.e002868.26","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1056\/NEJMoa2209041","article-title":"Spontaneous-Breathing Trials with Pressure-Support Ventilation or a T-Piece","volume":"387","author":"Thille","year":"2022","journal-title":"N Engl J Med"},{"key":"2026010701504576000_12.1.e002868.27","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.1001\/jama.2019.7234","article-title":"Effect of Pressure Support vs T-Piece Ventilation Strategies During Spontaneous Breathing Trials on Successful Extubation Among Patients Receiving Mechanical Ventilation: A Randomized Clinical Trial","volume":"321","author":"Subir\u00e0","year":"2019","journal-title":"JAMA"},{"key":"2026010701504576000_12.1.e002868.28","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1513\/AnnalsATS.202008-968OC","article-title":"Mechanical Ventilation Discontinuation Practices in Asia: A Multinational Survey","volume":"18","author":"Leung","year":"2021","journal-title":"Ann Am Thorac Soc"},{"key":"2026010701504576000_12.1.e002868.29","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1164\/rccm.201607-1338OC","article-title":"Effort to Breathe with Various Spontaneous Breathing Trial Techniques. A Physiologic Meta-analysis","volume":"195","author":"Sklar","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"2026010701504576000_12.1.e002868.30","doi-asserted-by":"publisher","DOI":"10.1186\/cc8142"},{"key":"2026010701504576000_12.1.e002868.31","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1164\/rccm.201610-2076ST","article-title":"Official Executive Summary of an American Thoracic Society\/American College of Chest Physicians Clinical Practice Guideline: Liberation from Mechanical Ventilation in Critically Ill Adults","volume":"195","author":"Schmidt","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"2026010701504576000_12.1.e002868.32","doi-asserted-by":"publisher","DOI":"10.1378\/chest.120.6_suppl.375S"},{"key":"2026010701504576000_12.1.e002868.33","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/s13613-019-0483-1","article-title":"Experts\u2019 guidelines of intubation and extubation of the ICU patient of French Society of Anaesthesia and Intensive Care Medicine (SFAR) and French-speaking Intensive Care Society (SRLF): In collaboration with the pediatric Association of French-speaking Anaesthetists and Intensivists (ADARPEF), French-speaking Group of Intensive Care and Paediatric emergencies (GFRUP) and Intensive Care physiotherapy society (SKR)","volume":"9","author":"Quintard","year":"2019","journal-title":"Ann Intensive Care"},{"key":"2026010701504576000_12.1.e002868.34","doi-asserted-by":"crossref","DOI":"10.1183\/13993003.01574-2021","article-title":"ERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure","volume":"59","author":"Oczkowski","year":"2022","journal-title":"Eur Respir J"},{"key":"2026010701504576000_12.1.e002868.35","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(08)60105-1"},{"key":"2026010701504576000_12.1.e002868.36","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM200005183422002"},{"key":"2026010701504576000_12.1.e002868.37","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2012.13872"},{"key":"2026010701504576000_12.1.e002868.38","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1906759"},{"key":"2026010701504576000_12.1.e002868.39","first-page":"322","article-title":"The weaning from mechanical ventilation: a comprehensive ultrasound approach","volume":"28","author":"Santangelo","year":"2022","journal-title":"Curr Opin Crit Care"},{"key":"2026010701504576000_12.1.e002868.40","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3182266408"},{"key":"2026010701504576000_12.1.e002868.41","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1007\/s00134-019-05892-8","article-title":"Respiratory muscle ultrasonography: methodology, basic and advanced principles and clinical applications in ICU and ED patients-a narrative review","volume":"46","author":"Tuinman","year":"2020","journal-title":"Intensive Care Med"},{"key":"2026010701504576000_12.1.e002868.42","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-015-0894-9","article-title":"Diaphragm ultrasound as indicator of respiratory effort in critically ill patients undergoing assisted mechanical ventilation: a pilot clinical study","volume":"19","author":"Umbrello","year":"2015","journal-title":"Crit Care"},{"key":"2026010701504576000_12.1.e002868.43","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-006-0339-7"},{"key":"2026010701504576000_12.1.e002868.44","doi-asserted-by":"crossref","DOI":"10.1186\/s13063-023-07171-w","article-title":"Effect of lung ultrasound-guided fluid deresuscitation on duration of ventilation in intensive care unit patients (CONFIDENCE): protocol for a multicentre randomised controlled trial","volume":"24","author":"Blok","year":"2023","journal-title":"Trials"},{"key":"2026010701504576000_12.1.e002868.45","doi-asserted-by":"publisher","DOI":"10.1378\/chest.121.2.549"},{"key":"2026010701504576000_12.1.e002868.46","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-018-2126-6"},{"key":"2026010701504576000_12.1.e002868.47","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1080\/17476348.2021.1933450","article-title":"Effectiveness, safety and efficacy of INTELLiVENT-adaptive support ventilation, a closed-loop ventilation mode for use in ICU patients - a systematic review","volume":"15","author":"Botta","year":"2021","journal-title":"Expert Rev Respir Med"},{"key":"2026010701504576000_12.1.e002868.48","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1097\/EJA.0000000000001972","article-title":"Effects of closed loop ventilation on ventilator settings, patient outcomes and ICU staff workloads - a systematic review","volume":"41","author":"Goossen","year":"2024","journal-title":"Eur J Anaesthesiol"},{"key":"2026010701504576000_12.1.e002868.49","first-page":"19","article-title":"Closed-loop ventilation","volume":"29","author":"Arnal","year":"2023","journal-title":"Curr Opin Crit Care"},{"key":"2026010701504576000_12.1.e002868.50","doi-asserted-by":"crossref","DOI":"10.1186\/s13063-022-06286-w","article-title":"Effect of Automated Closed-loop ventilation versus convenTional VEntilation on duration and quality of ventilation in critically ill patients (ACTiVE) - study protocol of a randomized clinical trial","volume":"23","author":"Botta","year":"2022","journal-title":"Trials"},{"key":"2026010701504576000_12.1.e002868.51","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-009-9124-8"},{"key":"2026010701504576000_12.1.e002868.52","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1001\/jama.2021.2384","article-title":"Ventilator Weaning and Discontinuation Practices for Critically Ill Patients","volume":"325","author":"Burns","year":"2021","journal-title":"JAMA"}],"container-title":["BMJ Open Respiratory Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjresp-2024-002868","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T09:51:41Z","timestamp":1767779501000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopenrespres.bmj.com\/lookup\/doi\/10.1136\/bmjresp-2024-002868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":52,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,7,21]]},"published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1136\/bmjresp-2024-002868"],"URL":"https:\/\/doi.org\/10.1136\/bmjresp-2024-002868","relation":{},"ISSN":["2052-4439"],"issn-type":[{"value":"2052-4439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]}}}