{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T20:55:48Z","timestamp":1782507348655,"version":"3.54.5"},"reference-count":14,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T00:00:00Z","timestamp":1761091200000},"content-version":"unspecified","delay-in-days":21,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Open Resp Res"],"accepted":{"date-parts":[[2025,9,5]]},"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The inherent unpredictability of COVID-19 has compelled clinicians to seek early predictors of in-hospital mortality. This study explored the association between mechanical power and in-hospital mortality in mechanically ventilated COVID-19 patients and provides an evidence-based foundation for mortality prediction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design and methods<\/jats:title>\n                    <jats:p>A multi-centre, retrospective analysis of 600 mechanically ventilated COVID-19 patients aged 18\u201398 years at 16 Texas Health Resources hospitals between 2020 and 2023 was conducted. Peak inspiratory pressure, static compliance, plateau pressure, driving pressure and mechanical power were analysed for association with in-hospital mortality. Mechanical power was further categorised to provide clinicians with a straightforward approach for mortality prediction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The overall in-hospital mortality was 57% (53% to 60%). All five parameters were strongly associated with mortality after adjusting for confounders. In the first 24-hours of mechanical ventilation, 72 patients with mechanical power below 10\u2009J\/min had a mortality of 31% (20% to 42%), 159 patients with mechanical power between 10\u2009J\/min and 15\u2009J\/min had a mortality of 47% (39% to 55%), and 369 patients with mechanical power greater than 15\u2009J\/min had a mortality of 66% (61% to 71%). Patients still intubated on day 7 had a 2.1% increase in mortality for each J\/min increase in mechanical power.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Mechanical power in the first 24 hours of mechanical ventilation in COVID-19 patients is associated with in-hospital mortality and is useful for clinical prognostication.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/bmjresp-2024-003131","type":"journal-article","created":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T07:00:21Z","timestamp":1761202821000},"page":"e003131","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":3,"title":["Mechanical power is an early predictor of mortality in mechanically ventilated patients with COVID-19"],"prefix":"10.1136","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-6524-2995","authenticated-orcid":false,"given":"Uday","family":"Rallabhandi","sequence":"first","affiliation":[{"name":"Texas Christian University Anne Burnett Marion School of Medicine, Fort Worth, Texas, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clark","family":"Walker","sequence":"additional","affiliation":[{"name":"Texas Health Resources, Fort Worth, Texas, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann","family":"Davis","sequence":"additional","affiliation":[{"name":"Texas Health Resources, Fort Worth, Texas, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J W","family":"Hollingsworth","sequence":"additional","affiliation":[{"name":"Texas Christian University Anne Burnett Marion School of Medicine, Fort Worth, Texas, USA"},{"name":"Texas Health Resources, Fort Worth, Texas, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,10,22]]},"reference":[{"key":"2026010701515001000_12.1.e003131.1","doi-asserted-by":"crossref","unstructured":"Auld SC , Caridi-Scheible M , Blum JM , et al . ICU and ventilator mortality among critically ill adults with covid-19. Intensive Care and Critical Care Medicine [Preprint]. doi:10.1101\/2020.04.23.20076737","DOI":"10.1101\/2020.04.23.20076737"},{"key":"2026010701515001000_12.1.e003131.2","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-023-34613-x","article-title":"An observational study on factors associated with ICU mortality in Covid-19 patients and critical review of the literature","volume":"13","author":"Lavrentieva","year":"2023","journal-title":"Sci Rep"},{"key":"2026010701515001000_12.1.e003131.3","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-018-31811-w","article-title":"Survival predictors in elderly patients with acute respiratory distress syndrome: a prospective observational cohort study","volume":"8","author":"Kao","year":"2018","journal-title":"Sci Rep"},{"key":"2026010701515001000_12.1.e003131.4","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-021-03667-6","article-title":"Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS","volume":"25","author":"Boscolo","year":"2021","journal-title":"Crit Care"},{"key":"2026010701515001000_12.1.e003131.5","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-019-2635-y","article-title":"Association between hospital mortality and inspiratory airway pressures in mechanically ventilated patients without acute respiratory distress syndrome: a prospective cohort study","volume":"23","author":"Sahetya","year":"2019","journal-title":"Crit Care"},{"key":"2026010701515001000_12.1.e003131.6","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-021-03710-6","article-title":"Association of intensity of ventilation with 28-day mortality in COVID-19 patients with acute respiratory failure: insights from the PRoVENT-COVID study","volume":"25","author":"Schuijt","year":"2021","journal-title":"Crit Care"},{"key":"2026010701515001000_12.1.e003131.7","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-016-4505-2"},{"key":"2026010701515001000_12.1.e003131.8","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-016-1556-2","article-title":"Effect of driving pressure on mortality in ARDS patients during lung protective mechanical ventilation in two randomized controlled trials","volume":"20","author":"Gu\u00e9rin","year":"2016","journal-title":"Crit Care"},{"key":"2026010701515001000_12.1.e003131.9","doi-asserted-by":"crossref","DOI":"10.1186\/s40560-023-00662-7","article-title":"Mechanical power and 30-day mortality in mechanically ventilated, critically ill patients with and without Coronavirus Disease-2019: a hospital registry study","volume":"11","author":"Azizi","year":"2023","journal-title":"J Intensive Care"},{"key":"2026010701515001000_12.1.e003131.10","doi-asserted-by":"crossref","DOI":"10.1016\/j.eclinm.2021.100765","article-title":"Estimating risk of mechanical ventilation and in-hospital mortality among adult COVID-19 patients admitted to Mass General Brigham: The VICE and DICE scores","volume":"33","author":"Nicholson","year":"2021","journal-title":"EClinicalMedicine"},{"key":"2026010701515001000_12.1.e003131.11","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0254525","article-title":"COVID-19 incidence and mortality in non-dialysis chronic kidney disease patients","volume":"16","author":"Gibertoni","year":"2021","journal-title":"PLoS One"},{"key":"2026010701515001000_12.1.e003131.12","doi-asserted-by":"crossref","first-page":"352","DOI":"10.5501\/wjv.v11.i5.352","article-title":"Mortality rate of COVID-19 infection in end stage kidney disease patients on maintenance hemodialysis: A systematic review and meta-analysis","volume":"11","author":"Cancarevic","year":"2022","journal-title":"World J Virol"},{"key":"2026010701515001000_12.1.e003131.13","doi-asserted-by":"crossref","DOI":"10.1186\/s40001-022-00841-6","article-title":"Early intubation and clinical outcomes in patients with severe COVID-19: a systematic review and meta-analysis","volume":"27","author":"Lee","year":"2022","journal-title":"Eur J Med Res"},{"key":"2026010701515001000_12.1.e003131.14","article-title":"Mechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes","volume":"4","author":"Rietveld","year":"2022","journal-title":"Crit Care Explor"}],"container-title":["BMJ Open Respiratory Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/bmjresp-2024-003131","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T09:53:17Z","timestamp":1767779597000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmjopenrespres.bmj.com\/lookup\/doi\/10.1136\/bmjresp-2024-003131"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,10,22]]},"published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1136\/bmjresp-2024-003131"],"URL":"https:\/\/doi.org\/10.1136\/bmjresp-2024-003131","relation":{},"ISSN":["2052-4439"],"issn-type":[{"value":"2052-4439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]}}}