{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T01:01:48Z","timestamp":1769043708006,"version":"3.49.0"},"reference-count":27,"publisher":"BMJ","issue":"10","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2013,6,17]]},"published-print":{"date-parts":[[2014,10]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To evaluate the ability of an electronic system created at the University of Washington to accurately document prerecorded VF and pulseless electrical activity (PEA) cardiac arrest scenarios compared with the American Heart Association paper cardiac arrest record.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>16 anaesthesiology residents were randomly assigned to view one of two prerecorded, simulated VF and PEA scenarios and asked to document the event with either the paper or electronic system. Each subject then repeated the process with the other video and documentation method. Five types of documentation errors were defined: (1) omission, (2) specification, (3) timing, (4) commission and (5) noise. The mean difference in errors between the paper and electronic methods was analysed using a single factor repeated measures ANOVA model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Compared with paper records, the electronic system omitted 6.3 fewer events (95% CI \u221210.1 to \u22122.5, p=0.003), which represents a 28% reduction in omission errors. Users recorded 2.9 fewer noise items (95% CI \u22125.3 to \u22120.6, p=0.003) when compared with paper, representing a 36% decrease in redundant or irrelevant information. The rate of timing (\u0394=\u22123.2, 95% CI \u22129.3 to 3.0, p=0.286) and commission (\u0394=\u22124.4, 95% CI \u22129.4 to 0.5, p=0.075) errors were similar between the electronic system and paper, while the rate of specification errors were about a third lower for the electronic system when compared with the paper record (\u0394=\u22123.2, 95% CI \u22126.3 to \u22120.2, p=0.037).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Compared with paper documentation, documentation with the electronic system captured 24% more critical information during a simulated medical emergency without loss in data quality.<\/jats:p><\/jats:sec>","DOI":"10.1136\/emermed-2013-202512","type":"journal-article","created":{"date-parts":[[2013,7,30]],"date-time":"2013-07-30T02:56:08Z","timestamp":1375152968000},"page":"833-839","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":25,"title":["Randomised trial comparing the recording ability of a novel, electronic emergency documentation system with the AHA paper cardiac arrest record"],"prefix":"10.1136","volume":"31","author":[{"given":"Eliot","family":"Grigg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Palmer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey","family":"Grigg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Oppenheimer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tim","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Axel","family":"Roesler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bala","family":"Nair","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Ross","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2013,7,29]]},"reference":[{"key":"2024052700342792000_31.10.833.1","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3182257459"},{"key":"2024052700342792000_31.10.833.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2004.12.020"},{"key":"2024052700342792000_31.10.833.3","unstructured":"Gartee R . Electronic health records: understanding and using computerized medical records. New York: Prentice Hall, 2011."},{"key":"2024052700342792000_31.10.833.4","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMsa0900592"},{"key":"2024052700342792000_31.10.833.5","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMsr1110507"},{"key":"2024052700342792000_31.10.833.6","doi-asserted-by":"publisher","DOI":"10.1377\/hlthaff.2010.0502"},{"key":"2024052700342792000_31.10.833.7","unstructured":"Institute of Medicine. Key capabilities of an electronic health record system. Washington, DC: National Academies Press, 2003."},{"key":"2024052700342792000_31.10.833.8","unstructured":"Benefits of Electronic Health Records. HealthIT.gov. US Department of Health and Human Services. http:\/\/www.healthit.gov\/providers-professionals\/benefits-electronic-health-records-ehrs (accessed 15 Jul 2012)."},{"key":"2024052700342792000_31.10.833.9","doi-asserted-by":"publisher","DOI":"10.1097\/JTN.0b013e31825629ab"},{"key":"2024052700342792000_31.10.833.10","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-200009000-00022"},{"key":"2024052700342792000_31.10.833.11","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1093\/bja\/aer163","article-title":"Does manual anaesthetic record capture remove clinically important data?","volume":"107","author":"van Schalkwyk","year":"2011","journal-title":"Br J Anaesth"},{"key":"2024052700342792000_31.10.833.12","first-page":"1454","article-title":"An observational study of anesthesia record completeness using an anesthesia information management system","volume":"104","author":"Driscoll","year":"2007","journal-title":"Technol Comput Simulation"},{"key":"2024052700342792000_31.10.833.13","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1177\/0310057X1003800615","article-title":"A comparison of electronic and handwritten anaesthetic records for completeness of information","volume":"38","author":"Wrightson","year":"2010","journal-title":"Anaesth Intensive Care"},{"key":"2024052700342792000_31.10.833.14","unstructured":"Philips HeartStart Event Review Pro. http:\/\/www.healthcare.philips.com\/us_en\/products\/resuscitation\/products\/event_review_pro_hospital\/ (accessed 9 Jun 2012)."},{"key":"2024052700342792000_31.10.833.15","unstructured":"Zoll CodeNet. http:\/\/www.zoll.com\/medical-products\/data-management\/code-net-resuscitation-system\/ (accessed 9 Jun 2012)."},{"key":"2024052700342792000_31.10.833.16","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(81)80378-2"},{"key":"2024052700342792000_31.10.833.17","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2009.086538"},{"key":"2024052700342792000_31.10.833.18","unstructured":"Au AP Ross BK Wolf FM . Review of in-hospital cardiac arrest emergency documentation (poster presentation). American Medical Informatics Association (AMIA) Annual Symposium; 2009."},{"key":"2024052700342792000_31.10.833.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.aucc.2011.08.002"},{"key":"2024052700342792000_31.10.833.20","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aem392"},{"key":"2024052700342792000_31.10.833.21","unstructured":"Adult\/Pedi Codesheet Vertical. American Heart Association. http:\/\/www.heart.org\/idc\/groups\/heart-public\/@wcm\/@private\/@hcm\/documents\/downloadable\/ucm_319599.pdf (accessed 15 Jun 2012)."},{"key":"2024052700342792000_31.10.833.22","unstructured":"Brooke J . SUS: a \u201cquick and dirty\u201d usability scale. In: Jordan PW Thomas B Weerdmeester BA . eds. Usability evaluation in industry. London: Taylor and Francis, 1996:189\u201394."},{"key":"2024052700342792000_31.10.833.23","doi-asserted-by":"publisher","DOI":"10.1080\/10447319509526110"},{"key":"2024052700342792000_31.10.833.24","unstructured":"Keppel G Wickens TD . Design and analysis: a researcher's handbook. 4th edn. Upper Saddle River, NJ: Pearson Prentice Hall, 2004."},{"key":"2024052700342792000_31.10.833.25","doi-asserted-by":"publisher","DOI":"10.1080\/10447310802205776"},{"key":"2024052700342792000_31.10.833.26","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(94)70099-0"},{"key":"2024052700342792000_31.10.833.27","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.852202"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2013-202512","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,27]],"date-time":"2024-05-27T07:34:42Z","timestamp":1716795282000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2013-202512"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,29]]},"references-count":27,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2014,9,16]]},"published-print":{"date-parts":[[2014,10]]}},"alternative-id":["10.1136\/emermed-2013-202512"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2013-202512","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"value":"1472-0205","type":"print"},{"value":"1472-0213","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,29]]}}}