{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T05:36:02Z","timestamp":1774935362980,"version":"3.50.1"},"reference-count":9,"publisher":"BMJ","issue":"5","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2014,2,1]]},"published-print":{"date-parts":[[2015,5]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>Cerebral oximetry using near-infrared spectroscopy measures regional cerebral oxygen saturation (rSO<jats:sub>2<\/jats:sub>) non-invasively and may provide information regarding the quality of cerebral oxygen perfusion. We determined whether the level of rSO<jats:sub>2<\/jats:sub>obtained during cardiopulmonary resuscitation is associated with return of spontaneous circulation (ROSC) and survival in Emergency Department (ED) patients presenting with cardiac arrest.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We conducted a retrospective, observational study of adult ED patients presenting at an academic medical centre with cardiac arrest in whom continuous cerebral oximetry was performed. Demographic and clinical data including age, gender, presenting rhythm and mean rSO<jats:sub>2<\/jats:sub>readings were abstracted. Cerebral oxygenation was measured with a commercially available oximeter.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A convenience study sample included 59 patients ages 18\u2013102\u2005years (mean age 68.7\u2009\u00b1\u200914.9 years); 50 (84.7%) were men. Presenting rhythms included pulseless electrical activity (21), asystole (20) and ventricular fibrillation\/tachycardia (17). 24 patients (40.6%) had ROSC and only 1 (1.7%) survived to hospital discharge. Patients with and without ROSC were similar in age and presenting cardiac rhythms. The mean of mean rSO<jats:sub>2<\/jats:sub>levels was higher in patients with ROSC, 43.8 (95% CI 40.1 to 47.6) compared with those without ROSC, 34.2 (95% CI 30.6 to 37.8); p=0.001. 91.7% of patients with ROSC had a rSO<jats:sub>2<\/jats:sub>of 30% or greater compared with 62.9% in those without ROSC (p=0.01). The area under the curve for mean rSO<jats:sub>2<\/jats:sub>as a predictor of ROSC was 0.76 (95% CI 0.64 to 0.89).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In ED patients with cardiac arrest higher cerebral oxygen saturations are associated with higher rates of ROSC.<\/jats:p><\/jats:sec>","DOI":"10.1136\/emermed-2013-203467","type":"journal-article","created":{"date-parts":[[2014,3,25]],"date-time":"2014-03-25T05:36:44Z","timestamp":1395725804000},"page":"353-356","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":42,"title":["Cerebral oximetry levels during CPR are associated with return of spontaneous circulation following cardiac arrest: an observational study"],"prefix":"10.1136","volume":"32","author":[{"given":"Adam J","family":"Singer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Loren A","family":"Inigo-Santiago","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr","given":"Henry C","family":"Thode","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark C","family":"Henry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sam","family":"Parnia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2014,3,24]]},"reference":[{"key":"2024052700551015000_32.5.353.1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0b013e318282ab8f"},{"key":"2024052700551015000_32.5.353.2","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0b013e3182456d46"},{"key":"2024052700551015000_32.5.353.3","first-page":"269","article-title":"Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo","volume":"82","author":"Pollard","year":"1996","journal-title":"Anesth Analg"},{"key":"2024052700551015000_32.5.353.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2012.01.039"},{"key":"2024052700551015000_32.5.353.5","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.186227"},{"key":"2024052700551015000_32.5.353.6","first-page":"107","article-title":"Near infrared spectroscopy during and after cardiac arrest-preliminary results","volume":"6","author":"Mullner","year":"1995","journal-title":"Clin Intensive Care"},{"key":"2024052700551015000_32.5.353.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2004.05.003"},{"key":"2024052700551015000_32.5.353.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2010.08.011"},{"key":"2024052700551015000_32.5.353.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2013.07.026"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2013-203467","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,27]],"date-time":"2024-05-27T07:55:20Z","timestamp":1716796520000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2013-203467"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,24]]},"references-count":9,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2015,4,18]]},"published-print":{"date-parts":[[2015,5]]}},"alternative-id":["10.1136\/emermed-2013-203467"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2013-203467","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"value":"1472-0205","type":"print"},{"value":"1472-0213","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3,24]]}}}