{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T10:38:52Z","timestamp":1794652732992,"version":"4.9.1"},"reference-count":25,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2017,5,9]]},"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Non-technical skills, such as task management, leadership, situational awareness, communication and decision-making refer to cognitive, behavioural and social skills that contribute to safe and efficient team performance. The importance of these skills during cardiopulmonary resuscitation (CPR) is increasingly emphasised. Nonetheless, the relationship between non-technical skills and technical performance is poorly understood. We hypothesise that non-technical skills become increasingly important under stressful conditions when individuals are distracted from their tasks, and investigated the relationship between non-technical and technical skills under control conditions and when external stressors are present.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this simulator-based randomised cross-over study, 30 anaesthesiologists and anaesthesia residents from the VU University Medical Center, Amsterdam, the Netherlands, participated in two different CPR scenarios in random order. In one scenario, external stressors (radio noise and a distractive scripted family member) were added, while the other scenario without stressors served as control condition. Non-technical performance of the team leader and technical performance of the team were measured using the \u2018Anaesthetists\u2019 Non-technical Skill\u2019 score and a recently developed technical skills score. Analysis of variance and Pearson correlation coefficients were used for statistical analyses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Non-technical performance declined when external stressors were present (adjusted mean difference 3.9 points, 95% CI 2.4 to 5.5 points). A significant correlation between non-technical and technical performance scores was observed when external stressors were present (r=0.67, 95% CI 0.40 to 0.83, p&lt;0.001), while no evidence for such a relationship was observed under control conditions (r=0.15, 95%\u2009CI \u22120.22 to 0.49, p=0.42). This was equally true for all individual domains of the non-technical performance score (task management, team working, situation awareness, decision-making).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>During CPR with external stressors, the team\u2019s technical performance is related to the non-technical skills of the team leader. This may have important implications for training of CPR teams.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/emermed-2016-205754","type":"journal-article","created":{"date-parts":[[2017,8,26]],"date-time":"2017-08-26T20:10:46Z","timestamp":1503778246000},"page":"728-733","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":105,"title":["Relationship between non-technical skills and technical performance during cardiopulmonary resuscitation: does stress have an influence?"],"prefix":"10.1136","volume":"34","author":[{"given":"Ralf","family":"Krage","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, VU University Medical Center, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Zwaan","sequence":"additional","affiliation":[{"name":"Institute of Medical Education Research Rotterdam, Erasmus Medical Center, Rotterdam, The Netherlands"},{"name":"EMGO Institute for Health and Care Research, VU University Medical Center, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lian","family":"Tjon Soei Len","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Rode Kruis Hospital, Beverwijk, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark W","family":"Kolenbrander","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Spaarne Gasthuis, Haarlem and Hoofddorp, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dick","family":"van Groeningen","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, VU University Medical Center, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan A","family":"Loer","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, VU University Medical Center, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cordula","family":"Wagner","sequence":"additional","affiliation":[{"name":"Department of Public and Occupational Health, EMGO Institute for Health and Care Research, Amsterdam, The Netherlands"},{"name":"NIVEL, Netherlands institute of Health Services Research, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Schober","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, VU University Medical Center, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2017,8,26]]},"reference":[{"key":"2025090502450918000_34.11.728.1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0b013e31829d8654"},{"key":"2025090502450918000_34.11.728.2","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000261"},{"key":"2025090502450918000_34.11.728.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2015.07.016"},{"key":"2025090502450918000_34.11.728.4","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.bpa.2015.02.002","article-title":"Basic concepts for crew resource management and non-technical skills","volume":"29","author":"Flin","year":"2015","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"2025090502450918000_34.11.728.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.03.017"},{"key":"2025090502450918000_34.11.728.6","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aes256"},{"key":"2025090502450918000_34.11.728.7","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1111\/anae.12747","article-title":"Does individual experience affect performance during cardiopulmonary resuscitation with additional external distractors?","volume":"69","author":"Krage","year":"2014","journal-title":"Anaesthesia"},{"key":"2025090502450918000_34.11.728.8","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeg112"},{"key":"2025090502450918000_34.11.728.9","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s41077-016-0013-2","article-title":"The reliability and usability of the Anesthesiologists\u2019 Non-Technical Skills (ANTS) system in simulation research","volume":"1","author":"Zwaan","year":"2016","journal-title":"Adv Simul"},{"key":"2025090502450918000_34.11.728.10","doi-asserted-by":"crossref","first-page":"24:24","DOI":"10.1186\/s13049-016-0216-5","article-title":"Non-technical skills evaluation in the critical care air ambulance environment: introduction of an adapted rating instrument--an observational study","volume":"24","author":"Myers","year":"2016","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"2025090502450918000_34.11.728.11","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/j.resuscitation.2014.06.027","article-title":"A description of communication patterns during CPR in ICU","volume":"85","author":"Taylor","year":"2014","journal-title":"Resuscitation"},{"key":"2025090502450918000_34.11.728.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.bpa.2011.02.005"},{"key":"2025090502450918000_34.11.728.13","doi-asserted-by":"publisher","DOI":"10.1097\/ACM.0b013e3181b37b8f"},{"key":"2025090502450918000_34.11.728.14","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2923.2012.04343.x"},{"key":"2025090502450918000_34.11.728.15","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000268"},{"key":"2025090502450918000_34.11.728.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2015.07.032"},{"key":"2025090502450918000_34.11.728.17","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jsurg.2015.01.020","article-title":"The role of nontechnical skills in simulated trauma resuscitation","volume":"72","author":"Briggs","year":"2015","journal-title":"J Surg Educ"},{"key":"2025090502450918000_34.11.728.18","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1111\/aas.12598","article-title":"Exploring the relationship between anaesthesiologists' non-technical and technical skills","volume":"60","author":"Gjeraa","year":"2016","journal-title":"Acta Anaesthesiol Scand"},{"key":"2025090502450918000_34.11.728.19","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.surge.2014.06.005","article-title":"Observation of behavioural markers of non-technical skills in the operating room and their relationship to intra-operative incidents","volume":"14","author":"Siu","year":"2016","journal-title":"Surgeon"},{"key":"2025090502450918000_34.11.728.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2003.08.004"},{"key":"2025090502450918000_34.11.728.21","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181cf7383"},{"key":"2025090502450918000_34.11.728.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2007.01.005"},{"key":"2025090502450918000_34.11.728.23","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeq136"},{"key":"2025090502450918000_34.11.728.24","first-page":"429","article-title":"Application of current guidelines for chest compression depth on different surfaces and using feedback devices: a randomized cross-over study","volume":"80","author":"Schober","year":"2014","journal-title":"Minerva Anestesiol"},{"key":"2025090502450918000_34.11.728.25","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2012-202064"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2016-205754","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T09:45:29Z","timestamp":1757065529000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2016-205754"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,26]]},"references-count":25,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2017,10,23]]},"published-print":{"date-parts":[[2017,11]]}},"alternative-id":["10.1136\/emermed-2016-205754"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2016-205754","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"value":"1472-0205","type":"print"},{"value":"1472-0213","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,26]]}}}