{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T02:50:45Z","timestamp":1770778245775,"version":"3.50.0"},"reference-count":17,"publisher":"BMJ","issue":"3","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2018,12,15]]},"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>The Wood\u2019s lamp, a handheld instrument that uses long-wave ultraviolet (UV) light with magnification of 2\u20133 times, is commonly used by non-ophthalmologists for examining patients with eye complaints. The goal of current research was to determine the sensitivity and specificity of the Wood\u2019s lamp for common eye abnormalities.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study design<\/jats:title><jats:p>We examined a convenience sample of patients, 18 years of age and older, who presented for eye complaints to an urgent clinic of a large ophthalmology practice. This prospective observational trial was performed from December 2016 until July 2017. An ophthalmologist examined the patient\u2019s eyes with a Wood\u2019s lamp, followed by examination of the eyes using a slit lamp. The Wood\u2019s lamp was compared with the slit lamp, which served as the gold standard.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There were 73 patients recruited. The mean age of study subjects (29 female and 44 male) was 49 years. The overall sensitivity of the Wood\u2019s lamp was 52% (38\/73; 95%\u2009CI 40% to 64%). Based on the principal final diagnosis made with the slit lamp, the Wood\u2019s lamp only detected 9 of 16 corneal abrasions, 5 of 10 corneal ulcers, 5 of 9 corneal foreign bodies, 0 of 4 cases of non-herpetic keratitis, 1 of 2 cases of herpes keratitis, 1 of 5 rust rings and 18 of 28 other diagnoses.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions and relevance<\/jats:title><jats:p>Examination using the Wood\u2019s lamp fails to detect many common eye abnormalities. Our findings support the need for a slit lamp examination of patients with eye complaints whenever possible.<\/jats:p><\/jats:sec>","DOI":"10.1136\/emermed-2018-208235","type":"journal-article","created":{"date-parts":[[2019,1,10]],"date-time":"2019-01-10T22:25:15Z","timestamp":1547159115000},"page":"159-162","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":6,"title":["Prospective study of the sensitivity of the Wood\u2019s lamp for common eye abnormalities"],"prefix":"10.1136","volume":"36","author":[{"given":"Edmond A","family":"Hooker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William J","family":"Faulkner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa D","family":"Kelly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert C","family":"Whitford","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2019,1,10]]},"reference":[{"key":"2024052709112076000_36.3.159.1","unstructured":"Agency for Healthcare Research and Quality Healthcare Cost and Utilization Project (HCUP). Overview of Healthcare Cost and Utilization Project (HCUP). https:\/\/www.hcup-us.ahrq.gov\/overview.jsp (Accessed 30 Jun\u00a02018)."},{"key":"2024052709112076000_36.3.159.2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-4362.1999.00794.x"},{"key":"2024052709112076000_36.3.159.3","first-page":"137","article-title":"Diagnosis and management of red eye in primary care","volume":"81","author":"Cronau","year":"2010","journal-title":"Am Fam Physician"},{"key":"2024052709112076000_36.3.159.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.emc.2007.10.002"},{"key":"2024052709112076000_36.3.159.5","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-6757(00)90120-7"},{"key":"2024052709112076000_36.3.159.6","doi-asserted-by":"crossref","first-page":"e295","DOI":"10.1016\/j.jemermed.2012.09.028","article-title":"Occult intraocular trauma: evaluation of the eye in an austere environment","volume":"44","author":"Sweet","year":"2013","journal-title":"J Emerg Med"},{"key":"2024052709112076000_36.3.159.7","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1016\/j.jemermed.2017.01.040","article-title":"The 2016 model of the clinical practice of emergency medicine","volume":"52","author":"Counselman","year":"2017","journal-title":"J Emerg Med"},{"key":"2024052709112076000_36.3.159.8","unstructured":"Tintinalli JE , Stapczynski JS , Oj M , et al . Tintinalli\u2019s Emergency Medicine: A Comprehensive Study Guide. 8th ed. New York: McGraw-Hill, 2016."},{"key":"2024052709112076000_36.3.159.9","unstructured":"Walls R , Hockberger R , Gausche-Hill M . Rosen\u2019s Emergency Medicine: Concepts and Clinical Practice. 9th ed. Philadelphia: Elsevier, 2018."},{"key":"2024052709112076000_36.3.159.10","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/ICL.0000000000000059","article-title":"Community practice patterns for bacterial corneal ulcer evaluation and treatment","volume":"41","author":"Park","year":"2015","journal-title":"Eye Contact Lens"},{"key":"2024052709112076000_36.3.159.11","first-page":"89","article-title":"Managing corneal foreign bodies in office-based general practice","volume":"46","author":"Fraenkel","year":"2017","journal-title":"Aust Fam Physician"},{"key":"2024052709112076000_36.3.159.12","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2008-2023"},{"key":"2024052709112076000_36.3.159.13","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1016\/j.annemergmed.2014.08.035","article-title":"Emergency department planning and resource guidelines","volume":"64","year":"2014","journal-title":"Ann Emerg Med"},{"key":"2024052709112076000_36.3.159.14","doi-asserted-by":"publisher","DOI":"10.1136\/emj.14.3.157"},{"key":"2024052709112076000_36.3.159.15","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2007.049999"},{"key":"2024052709112076000_36.3.159.16","first-page":"266","article-title":"Corneal foreign body management in an A&E department","volume":"15","author":"Feizerfan","year":"2010","journal-title":"Clin Gov Int J"},{"key":"2024052709112076000_36.3.159.17","first-page":"152","article-title":"Procedural skills training during emergency medicine residency: are we teaching the right things?","volume":"10","author":"Druck","year":"2009","journal-title":"West J Emerg Med"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2018-208235","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,27]],"date-time":"2024-05-27T16:11:59Z","timestamp":1716826319000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2018-208235"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,10]]},"references-count":17,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2019,2,26]]},"published-print":{"date-parts":[[2019,3]]}},"alternative-id":["10.1136\/emermed-2018-208235"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2018-208235","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"value":"1472-0205","type":"print"},{"value":"1472-0213","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,10]]}}}