{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T04:05:59Z","timestamp":1750824359294,"version":"3.41.0"},"reference-count":19,"publisher":"BMJ","issue":"9","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2023,6,16]]},"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Transcutaneous carbon dioxide (Ptcco<jats:sub>2<\/jats:sub>) measurement is a non-invasive surrogate marker for arterial carbon dioxide (Paco<jats:sub>2<\/jats:sub>), which requires invasive arterial blood sampling. Use of Ptcco<jats:sub>2<\/jats:sub>has been examined in different clinical settings, however, most existing evidence in the adult emergency department (ED) setting shows insufficient agreement between the measurements. This study assessed the level of agreement between Ptcco<jats:sub>2<\/jats:sub>and Paco<jats:sub>2<\/jats:sub>in undifferentiated adult ED patients across multiple timepoints.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This prospective observational study (study period 2020\u20132021) assessed paired Ptcco<jats:sub>2<\/jats:sub>and Paco<jats:sub>2<\/jats:sub>measurements at four consecutive timepoints (0, 30, 60 and 90\u2009min) in adult (aged 18 years or over) Australian ED patients requiring hospital admission and arterial catheter insertion. Agreement between the pairs was assessed using Bland-Altman analysis. It was prospectively determined by expert consensus that limits of \u00b14\u2009mm\u2009Hg would be a clinically acceptable level of agreement between Ptcco<jats:sub>2<\/jats:sub>and Paco<jats:sub>2<\/jats:sub>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>During the study period 168 paired Ptcco<jats:sub>2<\/jats:sub>and Paco<jats:sub>2<\/jats:sub>readings were taken from 42 adult ED patients. Bland-Altman analysis showed a mean Ptcco<jats:sub>2<\/jats:sub>reading 3.85\u2009mm\u2009Hg higher than Paco<jats:sub>2,<\/jats:sub>although at each timepoint the 95% CIs breached the limit of 4\u2009mm\u2009Hg difference. In addition, only 66% (111\/168) of results fell within the clinically acceptable range.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The level of agreement between Ptcco<jats:sub>2<\/jats:sub>and Paco<jats:sub>2<\/jats:sub>measurements may not be sufficiently precise for the adoption of Ptcco<jats:sub>2<\/jats:sub>monitoring in patients presenting to the ED.<\/jats:p><\/jats:sec>","DOI":"10.1136\/emermed-2022-212465","type":"journal-article","created":{"date-parts":[[2023,7,21]],"date-time":"2023-07-21T17:28:21Z","timestamp":1689960501000},"page":"646-650","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Prospective, observational study investigating the level of agreement between transcutaneous and invasive carbon dioxide measurements in critically ill emergency department patients"],"prefix":"10.1136","volume":"40","author":[{"given":"Scott","family":"Farenden","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yewon","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1865-7257","authenticated-orcid":false,"given":"Amy","family":"Cui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian","family":"Ferguson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2023,7,21]]},"reference":[{"key":"2025062323101292000_40.9.646.1","unstructured":"World Health Organisation . WHO guidelines on drawing blood: best practices in phlebotomy. Geneva, Switzerland: WHO Press, 2010."},{"key":"2025062323101292000_40.9.646.2","doi-asserted-by":"publisher","DOI":"10.1097\/MEJ.0b013e32836437cf"},{"key":"2025062323101292000_40.9.646.3","first-page":"117956031984586","article-title":"Agreement and correlation of arterial and venous blood gas analysis in a diverse population","volume":"10","author":"Chung","year":"2019","journal-title":"Clinical Medicine Insights: Trauma and Intensive Medicine"},{"key":"2025062323101292000_40.9.646.4","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2017-211466"},{"key":"2025062323101292000_40.9.646.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2010.11.010"},{"key":"2025062323101292000_40.9.646.6","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.08510"},{"key":"2025062323101292000_40.9.646.7","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2012-202228"},{"key":"2025062323101292000_40.9.646.8","doi-asserted-by":"crossref","DOI":"10.1186\/s13049-015-0154-7","article-title":"Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-centre, prospective and observational study","volume":"23","author":"Bobbia","year":"2015","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"2025062323101292000_40.9.646.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2012.03.033"},{"key":"2025062323101292000_40.9.646.10","unstructured":"Ferguson I , Farenden S . ACTRN12619001431112. Australian New Zealand clinical trials Registry. 2019. Available: https:\/\/www.anzctr.org.au\/Trial\/Registration\/TrialReview.aspx?id=378389&isReview=true"},{"key":"2025062323101292000_40.9.646.11","unstructured":"Parameter: transcutaneous partial pressure of carbon dioxide | serial number: 308444 | Firmware: V06.02.00\/V08.02.1 | company: Sentec AG, Therwil, Switzerland. n.d. Available: https:\/\/www.sentec.com\/fileadmin\/documents\/Labeling\/Instruction_Manuals\/Archive\/HB-005771-m-SDMS_InstructionManual_EN.pdf"},{"key":"2025062323101292000_40.9.646.12","doi-asserted-by":"publisher","DOI":"10.1513\/AnnalsATS.201311-387FR"},{"key":"2025062323101292000_40.9.646.13","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.jcrc.2015.09.014","article-title":"Superiority of transcutaneous CO2 over end-tidal CO2 measurement for monitoring respiratory failure in Nonintubated patients: a pilot study","volume":"31","author":"Lermuzeaux","year":"2016","journal-title":"J Crit Care"},{"key":"2025062323101292000_40.9.646.14","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2011.02164.x"},{"key":"2025062323101292000_40.9.646.15","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04212"},{"key":"2025062323101292000_40.9.646.16","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1159\/000521809","article-title":"Accuracy of a novel transcutaneous PCO2 and PO2 sensor with optical PO2 measurement in neonatal intensive care: a single-centre prospective clinical trial","volume":"119","author":"Baumann","year":"2022","journal-title":"Neonatology"},{"key":"2025062323101292000_40.9.646.17","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.rmed.2016.01.017","article-title":"Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation","volume":"112","author":"Aarrestad","year":"2016","journal-title":"Respiratory Medicine"},{"key":"2025062323101292000_40.9.646.18","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-010-2076-1"},{"key":"2025062323101292000_40.9.646.19","doi-asserted-by":"publisher","DOI":"10.1378\/chest.127.5.1744"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2022-212465","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T06:10:36Z","timestamp":1750745436000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2022-212465"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,21]]},"references-count":19,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,8,23]]},"published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.1136\/emermed-2022-212465"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2022-212465","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"type":"print","value":"1472-0205"},{"type":"electronic","value":"1472-0213"}],"subject":[],"published":{"date-parts":[[2023,7,21]]}}}