{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T00:18:58Z","timestamp":1792628338054,"version":"4.5.0"},"reference-count":25,"publisher":"BMJ","issue":"5","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Emerg Med J"],"accepted":{"date-parts":[[2024,2,3]]},"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Management of acute kidney injury (AKI) in the ED can be difficult due to uncertainty regarding the aetiology. This study investigated the diagnostic value of venous system ultrasound for determining the aetiological subtypes of AKI in the ED.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This multidisciplinary prospective cohort study was conducted in a single academic ED over the course of a year. Adult patients with AKI were evaluated using the venous excess ultrasound (VExUS) score, which is a four-step ultrasound protocol. The protocol begins with the inferior vena cava (IVC) measurement and examines organ flow patterns, including portal, hepatic and renal veins in the presence of dilated IVC. The AKI subtypes (hypovolaemia, cardiorenal, systemic vasodilatation and renal) were adjudicated by nephrologists and emergency physicians, considering data that became available during the hospitalisation. We determined the diagnostic test characteristics of VExUS for identifying each of the four AKI aetiological subtypes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>150 patients with AKI were included in the study. Hypovolaemia was the most frequent finally adjudicated cause of AKI (66%), followed by cardiorenal (18%), systemic vasodilatation (8.7%) and renal (7.3%). In diagnosing the cardiorenal subtype, the area under the curve (AUC) for VExUS grade &gt;0 was 0.819, with 77.8% sensitivity and 80.5% specificity, and the AUC for IVC maximum diameter &gt;20.4\u2009mm was 0.865, with 74.1% sensitivity and 86.2% specificity. For the hypovolaemia subtype, the AUC for VExUS grade \u22640 was 0.711, with 83.8% sensitivity and 56.9% specificity, and the AUC for IVC maximum diameter \u226416.8\u2009mm was 0.736, with 73.7% sensitivity and 68.6% specificity. None of the parameters achieved adequate test characteristics for renal and systemic vasodilatation subtypes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The VExUS score has good diagnostic accuracy for cardiorenal AKI and fair accuracy for hypovolaemic AKI but cannot identify renal and systemic vasodilatation subtypes. It should not therefore be used in isolation to determine the cause of AKI in the ED.<\/jats:p><\/jats:sec><jats:sec><jats:title>Trial registration number<\/jats:title><jats:p><jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"clintrialgov\" xlink:href=\"NCT04948710\">NCT04948710<\/jats:ext-link>.<\/jats:p><\/jats:sec>","DOI":"10.1136\/emermed-2023-213241","type":"journal-article","created":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T18:20:32Z","timestamp":1707934832000},"page":"304-310","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Diagnostic accuracy of venous system ultrasound for subtypes of acute kidney injury"],"prefix":"10.1136","volume":"41","clinical-trial-number":[{"clinical-trial-number":"nct04948710","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct04948710","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7851-7881","authenticated-orcid":false,"given":"Mehmet Ali","family":"Aslaner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1382-2439","authenticated-orcid":false,"given":"\u00d6zant","family":"Helvac\u0131","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2331-5107","authenticated-orcid":false,"given":"Korbin","family":"Haycock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0330-2595","authenticated-orcid":false,"given":"\u0130sa","family":"K\u0131l\u0131\u00e7aslan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emre","family":"Ya\u015far","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2878-6052","authenticated-orcid":false,"given":"Mahi Nur","family":"Cerit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1690-2538","authenticated-orcid":false,"given":"Halit Nahit","family":"\u015eendur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9146-2133","authenticated-orcid":false,"given":"Galip","family":"G\u00fcz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7993-8098","authenticated-orcid":false,"given":"Ahmet","family":"Demircan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2024,2,14]]},"reference":[{"key":"2025062323401891000_41.5.304.1","doi-asserted-by":"crossref","first-page":"2009","DOI":"10.1016\/j.ultrasmedbio.2022.05.025","article-title":"Accuracy of multi-organ point-of-care ultrasound for acute kidney injury etiologies","volume":"48","author":"Aslaner","year":"2022","journal-title":"Ultrasound Med Biol"},{"key":"2025062323401891000_41.5.304.2","doi-asserted-by":"crossref","DOI":"10.1186\/s12882-017-0792-2","article-title":"Risk factors for community-acquired acute kidney injury in patients with and without chronic kidney injury and impact of its initial management on prognosis: a prospective observational study","volume":"18","author":"Stucker","year":"2017","journal-title":"BMC Nephrol"},{"key":"2025062323401891000_41.5.304.3","doi-asserted-by":"publisher","DOI":"10.1111\/nep.12036"},{"key":"2025062323401891000_41.5.304.4","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1093\/ehjacc\/zuac104","article-title":"Fluid management in acute kidney injury: from evaluating fluid responsiveness towards assessment of fluid tolerance","volume":"11","author":"Argaiz","year":"2022","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"2025062323401891000_41.5.304.5","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/j.chest.2019.04.004","article-title":"Fluid management in acute kidney injury","volume":"156","author":"Ostermann","year":"2019","journal-title":"Chest"},{"key":"2025062323401891000_41.5.304.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2016.05.009"},{"key":"2025062323401891000_41.5.304.7","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0096(199801)26:1<27::AID-JCU6>3.0.CO;2-L"},{"key":"2025062323401891000_41.5.304.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2016.03.016"},{"key":"2025062323401891000_41.5.304.9","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1159\/000511714","article-title":"Dynamic changes in portal vein flow during decongestion in patients with heart failure and cardio-renal syndrome: a POCUS case series","volume":"11","author":"Argaiz","year":"2021","journal-title":"Cardiorenal Med"},{"key":"2025062323401891000_41.5.304.10","doi-asserted-by":"crossref","DOI":"10.1186\/s13089-020-00163-w","article-title":"Quantifying systemic congestion with point-of-care ultrasound: development of the venous excess ultrasound grading system","volume":"12","author":"Beaubien-Souligny","year":"2020","journal-title":"Ultrasound J"},{"key":"2025062323401891000_41.5.304.11","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1093\/ehjacc\/zuad048","article-title":"Venous excess ultrasound score and acute kidney injury in patients with acute coronary syndrome","volume":"12","author":"Viana-Rojas","year":"2023","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"2025062323401891000_41.5.304.12","doi-asserted-by":"crossref","first-page":"783","DOI":"10.5005\/jp-journals-10071-23570","article-title":"Combination of inferior vena cava diameter, hepatic venous flow, and portal vein pulsatility index: venous excess ultrasound score (VEXUS score) in predicting acute kidney injury in patients with cardiorenal syndrome: a prospective cohort study","volume":"24","author":"Bhardwaj","year":"2020","journal-title":"Indian J Crit Care Med"},{"key":"2025062323401891000_41.5.304.13","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.4103\/0366-6999.205848","article-title":"Monitoring changes in hepatic venous velocities flow after a fluid challenge can identify shock patients who lack fluid responsiveness","volume":"130","author":"Du","year":"2017","journal-title":"Chin Med J (Engl)"},{"key":"2025062323401891000_41.5.304.14","doi-asserted-by":"publisher","DOI":"10.1038\/kisup.2011.32"},{"key":"2025062323401891000_41.5.304.15","doi-asserted-by":"crossref","first-page":"276","DOI":"10.11613\/BM.2012.031","article-title":"Interrater reliability: the kappa statistic","volume":"22","author":"McHugh","year":"2012","journal-title":"Biochem Med (Zagreb)"},{"key":"2025062323401891000_41.5.304.16","doi-asserted-by":"publisher","DOI":"10.4097\/kja.21209"},{"key":"2025062323401891000_41.5.304.17","doi-asserted-by":"publisher","DOI":"10.2307\/2531595"},{"key":"2025062323401891000_41.5.304.18","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2020.3871","article-title":"Adherence to the standards for reporting of diagnostic accuracy (STARD) 2015 guidelines in acute point-of-care ultrasound research","volume":"3","author":"Prager","year":"2020","journal-title":"JAMA Netw Open"},{"key":"2025062323401891000_41.5.304.19","unstructured":"Sample size calculator. Available: http:\/\/www.raosoft.com\/samplesize.html [Accessed 26 Jul 2023]."},{"key":"2025062323401891000_41.5.304.20","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-023-04524-4","article-title":"Prevalence of systemic venous congestion assessed by Venous Excess Ultrasound Grading System (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study","volume":"27","author":"Andrei","year":"2023","journal-title":"Crit Care"},{"key":"2025062323401891000_41.5.304.21","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-022-04180-0","article-title":"Doppler study of portal vein and renal venous velocity predict the appropriate fluid response to diuretic in ICU: a prospective observational echocardiographic evaluation","volume":"26","author":"Guinot","year":"2022","journal-title":"Crit Care"},{"key":"2025062323401891000_41.5.304.22","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1007\/s11739-022-03003-y","article-title":"Internal jugular vein ultrasound for the diagnosis of hypovolemia and hypervolemia in acutely ill adults: a systematic review and meta-analysis","volume":"17","author":"Wang","year":"2022","journal-title":"Intern Emerg Med"},{"key":"2025062323401891000_41.5.304.23","doi-asserted-by":"crossref","first-page":"1414","DOI":"10.1016\/j.ajem.2011.10.017","article-title":"Role of inferior vena cava diameter in assessment of volume status: a meta-analysis","volume":"30","author":"Dipti","year":"2012","journal-title":"Am J Emerg Med"},{"key":"2025062323401891000_41.5.304.24","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1177\/0885066619887333","article-title":"Semiquantitative power doppler ultrasound score to predict acute kidney injury in patients with sepsis or cardiac failure: a prospective observational study","volume":"36","author":"Zhi","year":"2021","journal-title":"J Intensive Care Med"},{"key":"2025062323401891000_41.5.304.25","doi-asserted-by":"crossref","DOI":"10.1155\/2022\/3472405","article-title":"Renal doppler ultrasound in the evaluation of renal function in patients with sepsis","volume":"2022","author":"Yu","year":"2022","journal-title":"Appl Bionics Biomech"}],"container-title":["Emergency Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/emermed-2023-213241","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T06:40:46Z","timestamp":1750747246000},"score":1,"resource":{"primary":{"URL":"https:\/\/emj.bmj.com\/lookup\/doi\/10.1136\/emermed-2023-213241"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,14]]},"references-count":25,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,4,22]]},"published-print":{"date-parts":[[2024,5]]}},"alternative-id":["10.1136\/emermed-2023-213241"],"URL":"https:\/\/doi.org\/10.1136\/emermed-2023-213241","relation":{},"ISSN":["1472-0205","1472-0213"],"issn-type":[{"value":"1472-0205","type":"print"},{"value":"1472-0213","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,14]]}}}