{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T22:24:46Z","timestamp":1769379886163,"version":"3.49.0"},"reference-count":32,"publisher":"BMJ","issue":"1","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart Asia"],"accepted":{"date-parts":[[2017,2,15]]},"published-print":{"date-parts":[[2017,3]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>We aimed to define the normal range of aortic and mitral valve thickness in healthy schoolchildren from a high prevalence rheumatic heart disease (RHD) region, using a standardised protocol for imaging and measurement.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Measurements were performed in 288 children without RHD. Anterior mitral valve leaflet (AMVL) thickness measurements were performed at the midpoint and tip of the leaflet in the parasternal long axis (PSLA) in diastole, when the AMVL was approximately parallel to the ventricular septum. Thickness of the aortic valve was measured from PSLA imaging in systole when the leaflets were at maximum excursion. The right coronary and non-coronary closure lines of the aortic valve were measured in diastole in parasternal short axis (PSSA) imaging. Results were compared with 51 children with RHD classified by World Heart Federation diagnostic criteria.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>In normal children, median AMVL tip thickness was 2.0\u2005mm (IQR 1.7\u20132.4) and median AMVL midpoint thickness 2.0\u2005mm (IQR 1.7\u20132.4). The median aortic valve thickness was 1.5\u2005mm (IQR 1.3\u20131.6) in the PSLA view and 1.4\u2005mm (IQR 1.2\u20131.6) in the PSSA view. The interclass correlation coefficient for the AMVL tip was 0.85 (0.71 to 0.92) and for the AMVL midpoint was 0.77 (0.54 to 0.87).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>We have described a standardised method for mitral and aortic valve measurement in children which is objective and reproducible. Normal ranges of left heart valve thickness in a high prevalence RHD population are established. These results provide a reference range for school-age children in high prevalence RHD regions undergoing echocardiographic screening.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/heartasia-2016-010872","type":"journal-article","created":{"date-parts":[[2017,3,21]],"date-time":"2017-03-21T21:12:31Z","timestamp":1490130751000},"page":"70-75","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":12,"title":["Normal echocardiographic mitral and aortic valve thickness in children"],"prefix":"10.1136","volume":"9","author":[{"given":"Rachel H","family":"Webb","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicola","family":"Culliford-Semmens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karishma","family":"Sidhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nigel J","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2017,3,21]]},"reference":[{"key":"2025090722214502000_9.1.70.1","doi-asserted-by":"publisher","DOI":"10.1097\/00000478-198604000-00007"},{"key":"2025090722214502000_9.1.70.2","doi-asserted-by":"publisher","DOI":"10.1161\/hc37t1.094707"},{"key":"2025090722214502000_9.1.70.3","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.60.4.299"},{"key":"2025090722214502000_9.1.70.4","doi-asserted-by":"publisher","DOI":"10.1038\/nrcardio.2012.7"},{"key":"2025090722214502000_9.1.70.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2010.06.036"},{"key":"2025090722214502000_9.1.70.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2003.09.087"},{"key":"2025090722214502000_9.1.70.7","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951106001296"},{"key":"2025090722214502000_9.1.70.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2010.01.364"},{"key":"2025090722214502000_9.1.70.9","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa065085"},{"key":"2025090722214502000_9.1.70.10","doi-asserted-by":"publisher","DOI":"10.1038\/ncpcardio1185"},{"key":"2025090722214502000_9.1.70.11","first-page":"327","article-title":"High prevalence of rheumatic heart disease by clinical and echocardiographic screening among children in Fiji","volume":"18","author":"Steer","year":"2009","journal-title":"J Heart Valve Dis"},{"key":"2025090722214502000_9.1.70.12","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951111000266"},{"key":"2025090722214502000_9.1.70.13","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2008.143982"},{"key":"2025090722214502000_9.1.70.14","first-page":"36","article-title":"Clinical and echocardiographic features of children with rheumatic heart disease and their serum cytokine profile","volume":"13","author":"Ali","year":"2012","journal-title":"Pan Afr Med J"},{"key":"2025090722214502000_9.1.70.15","first-page":"148","article-title":"Echocardiographic evaluation of mitral valve in patients with pure rheumatic mitral regurgitation","volume":"49","author":"Atalay","year":"2007","journal-title":"Turk J Pediatr"},{"key":"2025090722214502000_9.1.70.16","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2012.02447.x"},{"key":"2025090722214502000_9.1.70.17","doi-asserted-by":"publisher","DOI":"10.1016\/0167-5273(95)02325-Q"},{"issue":"2","key":"2025090722214502000_9.1.70.18","doi-asserted-by":"crossref","first-page":"e116","DOI":"10.1016\/j.gheart.2016.03.404","article-title":"PM275 Comparison of criteria for echocardiographic diagnosis of rheumatic heart disease: WHO\/NIH criteria vs World Heart Federation Criteria","volume":"11","author":"Culliford-Semmens","year":"2016","journal-title":"Global Heart"},{"key":"2025090722214502000_9.1.70.19","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(88)90971-X"},{"key":"2025090722214502000_9.1.70.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2013.09.013"},{"key":"2025090722214502000_9.1.70.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2015.07.005"},{"key":"2025090722214502000_9.1.70.22","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1017\/S1047951115001857","article-title":"Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars","volume":"26","author":"Z\u00fchlke","year":"2016","journal-title":"Cardiol Young"},{"key":"2025090722214502000_9.1.70.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2015.04.007"},{"key":"2025090722214502000_9.1.70.24","doi-asserted-by":"crossref","first-page":"e386","DOI":"10.1016\/S2214-109X(16)30065-1","article-title":"Focused cardiac ultrasound screening for rheumatic heart disease by briefly trained health workers: a study of diagnostic accuracy","volume":"4","author":"Engelman","year":"2016","journal-title":"Lancet Glob Health"},{"key":"2025090722214502000_9.1.70.25","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.ijcard.2015.11.110","article-title":"Echocardiography-based screening for rheumatic heart disease: what does borderline mean?","volume":"203","author":"Bacquelin","year":"2016","journal-title":"Int J Cardiol"},{"key":"2025090722214502000_9.1.70.26","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2015.01.001"},{"key":"2025090722214502000_9.1.70.27","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/0167-5273(89)90054-5","article-title":"Surgical pathology of mitral valves\u2014the Indian scene","volume":"24","author":"Ratnakar","year":"1989","journal-title":"Int J Cardiol"},{"key":"2025090722214502000_9.1.70.28","first-page":"676","article-title":"Rheumatic heart disease in the past decade: an autopsy analysis","volume":"54","author":"Deshpande","year":"2002","journal-title":"Indian Heart J"},{"key":"2025090722214502000_9.1.70.29","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1540-8175.2007.00575.x","article-title":"Tissue harmonic imaging in echocardiography: better valve imaging, but at what cost?","volume":"25","author":"Hawkins","year":"2008","journal-title":"Echocardiography"},{"key":"2025090722214502000_9.1.70.30","first-page":"204","article-title":"Influence of different echocardiographic imaging modes on the assessment of anterior mitral leaflet thickness","volume":"14","author":"Gorgulu","year":"2005","journal-title":"J Heart Valve Dis"},{"key":"2025090722214502000_9.1.70.31","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2002.121537"},{"key":"2025090722214502000_9.1.70.32","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/0002-8703(80)90276-8","article-title":"Rheumatic mitral stenosis: cross-sectional echocardiographic analysis","volume":"100","author":"Naito","year":"1980","journal-title":"Am Heart J"}],"container-title":["Heart Asia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartasia-2016-010872","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T05:21:53Z","timestamp":1757308913000},"score":1,"resource":{"primary":{"URL":"https:\/\/heartasia.bmj.com\/lookup\/doi\/10.1136\/heartasia-2016-010872"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,3,21]]},"published-print":{"date-parts":[[2017,3]]}},"alternative-id":["10.1136\/heartasia-2016-010872"],"URL":"https:\/\/doi.org\/10.1136\/heartasia-2016-010872","relation":{},"ISSN":["1759-1104"],"issn-type":[{"value":"1759-1104","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3]]}}}