{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T22:28:54Z","timestamp":1781821734361,"version":"3.54.5"},"reference-count":48,"publisher":"BMJ","issue":"Suppl 2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"accepted":{"date-parts":[[2018,10,16]]},"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:p>Minimally invasive aortic valve replacement (MIAVR) is defined as a surgical aortic valve replacement which involves smaller chest incisions as opposed to full sternotomy. It is performed using cardiopulmonary bypass with cardiac arrest. It benefits from potential advantages of a less invasive procedure. To date, over 14 000 MIAVR have been reported in the literature. Due to heterogeneity of the studies, different surgical techniques and mainly the non-randomised nature of these studies comparing MIAVR with conventional aortic valve replacement, it is difficult to draw definitive conclusions. The two main techniques of MIAVR are mini-sternotomy and right anterior mini-thoracotomy. Both techniques with other less common forms of MIAVR will be discussed in this review. The advantages, disadvantages and surgical pitfalls will be discussed. Some of the advantages include shorter intensive care and hospital stay, reduced perioperative blood loss, less pain, improved respiratory function and cosmesis. The possible disadvantage of longer bypass and cross-clamp times may be counter balanced by the recent sutureless and rapid deployment valves. Despite some of the benefits, MIAVR has not been adopted by a significant proportion of the surgeons possibly related to the learning curve and requirements for re-training. As MIAVR becomes more common, randomised trials comparing this technique with transcatheter aortic valve implantation is warranted. In addition, assessing quality of life including return to work and functional capacity is needed.<\/jats:p>","DOI":"10.1136\/heartjnl-2018-313512","type":"journal-article","created":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T14:35:25Z","timestamp":1551969325000},"page":"s10-s15","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":40,"title":["Minimally invasive surgical aortic valve replacement"],"prefix":"10.1136","volume":"105","author":[{"given":"Marjan","family":"Jahangiri","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic Surgery, St George\u2019s Hospital, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azhar","family":"Hussain","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, St George\u2019s Hospital, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enoch","family":"Akowuah","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, South Tees NHS Foundation Trust, North Yorkshire, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"2025100703234329000_105.Suppl_2.s10.1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.176857"},{"key":"2025100703234329000_105.Suppl_2.s10.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2009.11.024"},{"key":"2025100703234329000_105.Suppl_2.s10.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.08.015"},{"key":"2025100703234329000_105.Suppl_2.s10.4","unstructured":"Blue Book Online. The Society for Cardiothoracic Surgery in Great Britain & Ireland. 2013.www.bluebook.scts.org"},{"key":"2025100703234329000_105.Suppl_2.s10.5","first-page":"307","article-title":"Aortic valve replacement through right thoracotomy","volume":"20","author":"Rao","year":"1993","journal-title":"Tex Heart Inst J"},{"key":"2025100703234329000_105.Suppl_2.s10.6","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(96)00418-3"},{"key":"2025100703234329000_105.Suppl_2.s10.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2007.12.037"},{"key":"2025100703234329000_105.Suppl_2.s10.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2012.03.064"},{"key":"2025100703234329000_105.Suppl_2.s10.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2005.12.011"},{"key":"2025100703234329000_105.Suppl_2.s10.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.08.010"},{"key":"2025100703234329000_105.Suppl_2.s10.11","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/S0003-4975(02)03911-5","article-title":"Minimal access aortic valve replacement: effects on morbidity and resource utilization","volume":"74","author":"Doll","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.09.019"},{"key":"2025100703234329000_105.Suppl_2.s10.13","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00072-7"},{"key":"2025100703234329000_105.Suppl_2.s10.14","doi-asserted-by":"publisher","DOI":"10.1097\/01.sla.0000137141.55267.47"},{"key":"2025100703234329000_105.Suppl_2.s10.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2007.09.038"},{"key":"2025100703234329000_105.Suppl_2.s10.16","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezu068"},{"key":"2025100703234329000_105.Suppl_2.s10.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2014.05.060"},{"key":"2025100703234329000_105.Suppl_2.s10.18","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.188525"},{"key":"2025100703234329000_105.Suppl_2.s10.19","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezt043"},{"key":"2025100703234329000_105.Suppl_2.s10.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2013.08.086"},{"key":"2025100703234329000_105.Suppl_2.s10.21","doi-asserted-by":"publisher","DOI":"10.1093\/icvts\/ivu428"},{"key":"2025100703234329000_105.Suppl_2.s10.22","first-page":"59","article-title":"Central versus femoral cannulation during minimally invasive aortic valve replacement","volume":"4","author":"Murzi","year":"2015","journal-title":"Ann Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2012.01.011"},{"key":"2025100703234329000_105.Suppl_2.s10.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2011.05.011"},{"key":"2025100703234329000_105.Suppl_2.s10.25","doi-asserted-by":"crossref","first-page":"27","DOI":"10.14797\/mdcj-12-1-27","article-title":"Aortic valve surgery: minimally invasive options","volume":"12","author":"Ramlawi","year":"2016","journal-title":"Methodist Debakey Cardiovasc J"},{"key":"2025100703234329000_105.Suppl_2.s10.26","first-page":"26","article-title":"Minimally invasive aortic valve surgery: state of the art and future directions","volume":"4","author":"Glauber","year":"2015","journal-title":"Ann Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.27","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-199710000-00003"},{"key":"2025100703234329000_105.Suppl_2.s10.28","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2013.07.060"},{"key":"2025100703234329000_105.Suppl_2.s10.29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2013.08.016"},{"key":"2025100703234329000_105.Suppl_2.s10.30","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-003-0176-6"},{"key":"2025100703234329000_105.Suppl_2.s10.31","first-page":"CD011793","article-title":"Limited versus full sternotomy for aortic valve replacement","volume":"4","author":"Kirmani","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"2025100703234329000_105.Suppl_2.s10.32","doi-asserted-by":"crossref","unstructured":"Nair SK , Sudarshan CD , Thorpe BS , et al . Mini-Stern trial: a randomized trial comparing mini-sternotomy to full median sternotomy for aortic valve replacement. J Thorac Cardiovasc Surg 2018. doi: 10.1016\/j.jtcvs.2018.05.057. [Epub ahead of print 4 Jun 2018].doi:10.1016\/j.jtcvs.2018.05.057","DOI":"10.1016\/j.jtcvs.2018.05.057"},{"key":"2025100703234329000_105.Suppl_2.s10.33","first-page":"38","article-title":"Minimally invasive aortic valve replacement versus aortic valve replacement through full sternotomy: the Brigham and Women\u2019s Hospital experience","volume":"4","author":"Neely","year":"2015","journal-title":"Ann Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.34","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s13019-017-0598-0","article-title":"Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy","volume":"12","author":"Bening","year":"2017","journal-title":"J Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.35","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1186\/s13019-015-0344-4","article-title":"Automated fastener versus manually tied knots in minimally invasive mitral valve repair: impact on operation time and short-term results","volume":"10","author":"Grapow","year":"2015","journal-title":"J Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.36","first-page":"e46","article-title":"Sutureless aortic valve replacement: a systematic review and meta-analysis","volume":"4","author":"Phan","year":"2015","journal-title":"Ann Cardiothorac Surg"},{"key":"2025100703234329000_105.Suppl_2.s10.37","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehv574"},{"key":"2025100703234329000_105.Suppl_2.s10.38","first-page":"887","article-title":"Propensity score analysis of a six-year experience with minimally invasive isolated aortic valve replacement","volume":"13","author":"Sharony","year":"2004","journal-title":"J Heart Valve Dis"},{"key":"2025100703234329000_105.Suppl_2.s10.39","doi-asserted-by":"publisher","DOI":"10.1532\/HSF98.20041104"},{"key":"2025100703234329000_105.Suppl_2.s10.40","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.03.055"},{"key":"2025100703234329000_105.Suppl_2.s10.41","first-page":"606","article-title":"Prospensity score-matched analysis of aortic valve replacement by mini-thoracotomy","volume":"19","author":"Ruttmann","year":"2010","journal-title":"J Hear Valve Dis"},{"key":"2025100703234329000_105.Suppl_2.s10.42","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezr230"},{"key":"2025100703234329000_105.Suppl_2.s10.43","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2013.04.102"},{"key":"2025100703234329000_105.Suppl_2.s10.44","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezv038"},{"key":"2025100703234329000_105.Suppl_2.s10.45","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezt616"},{"key":"2025100703234329000_105.Suppl_2.s10.46","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2014.09.022"},{"key":"2025100703234329000_105.Suppl_2.s10.47","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2011.12.008"},{"key":"2025100703234329000_105.Suppl_2.s10.48","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2009.03.011"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2018-313512","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T10:23:54Z","timestamp":1759832634000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2018-313512"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":48,"journal-issue":{"issue":"Suppl 2","published-online":{"date-parts":[[2019,3,7]]},"published-print":{"date-parts":[[2019,3]]}},"alternative-id":["10.1136\/heartjnl-2018-313512"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2018-313512","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}