{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:47:42Z","timestamp":1780469262509,"version":"3.54.1"},"reference-count":30,"publisher":"BMJ","issue":"Suppl 2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"accepted":{"date-parts":[[2018,11,20]]},"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:p>Patient-specific computer simulation consists of the assessment of the interaction of the device with the host based on the integration of the detailed geometric and biomechanical properties of the device and host. Hence, it allows the prediction of valve performance (efficacy) and complications (safety) and may consequently help the physician to select the valve\/device that best fits the individual patient, thereby improving outcome. There is currently little awareness and information in clinical medicine on patient-specific computer simulation. In this paper, we describe the technical background and a number of illustrations to illustrate how patient-specific computer simulation may be used for catheter-based treatment planning of acquired heart disease.<\/jats:p>","DOI":"10.1136\/heartjnl-2018-313514","type":"journal-article","created":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T14:35:25Z","timestamp":1551969325000},"page":"s21-s27","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":31,"title":["Patient-specific computer simulation for transcatheter cardiac interventions: what a clinician needs to know"],"prefix":"10.1136","volume":"105","author":[{"given":"Peter","family":"de Jaegere","sequence":"first","affiliation":[{"name":"Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giorgia","family":"Rocatello","sequence":"additional","affiliation":[{"name":"IBiTech-bioMMeda, Ghent University, Ghent, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernard D","family":"Prendergast","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Guy\u2019s and St Thomas\u2019 NHS Foundation Trust London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ole","family":"de Backer","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Rigshospitalet University Hospital, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas M","family":"Van Mieghem","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronak","family":"Rajani","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Guy\u2019s and St Thomas\u2019 NHS Foundation Trust London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"2025100704360172000_105.Suppl_2.s21.1","unstructured":"https:\/\/esc365.escardio.org\/Search-Results?vgnextkeyword=digital+health"},{"key":"2025100704360172000_105.Suppl_2.s21.2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu312"},{"key":"2025100704360172000_105.Suppl_2.s21.3","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1514616"},{"key":"2025100704360172000_105.Suppl_2.s21.4","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","article-title":"Surgical or transcatheter aortic-valve replacement in intermediate-risk patients","volume":"376","author":"Reardon","year":"2017","journal-title":"N Engl J Med"},{"key":"2025100704360172000_105.Suppl_2.s21.5","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1093\/eurheartj\/ehy107","article-title":"Annual number of candidates for transcatheter aortic valve implantation per country: current estimates and future projections","volume":"39","author":"Durko","year":"2018","journal-title":"Eur Heart J"},{"key":"2025100704360172000_105.Suppl_2.s21.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.02.054"},{"key":"2025100704360172000_105.Suppl_2.s21.7","doi-asserted-by":"crossref","unstructured":"Majule DN , Jing C , Rutahoile WM , et al . The efficacy and safety of the watchman device in laa occlusion in patients with non-valvular atrial fibrillation contraindicated to oral anticoagulation: A focused review. Ann Thorac Cardiovasc Surg 2018.doi:10.5761\/atcs.ra.18-00014","DOI":"10.5761\/atcs.ra.18-00014"},{"key":"2025100704360172000_105.Suppl_2.s21.8","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2017-311586"},{"key":"2025100704360172000_105.Suppl_2.s21.9","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/s12471-016-0923-6","article-title":"Patient-specific computer modelling - its role in the planning of transcatheter aortic valve implantation","volume":"25","author":"El Faquir","year":"2017","journal-title":"Neth Heart J"},{"key":"2025100704360172000_105.Suppl_2.s21.10","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV11I9A212"},{"key":"2025100704360172000_105.Suppl_2.s21.11","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jcct.2017.12.007","article-title":"Transcatheter mitral valve replacement in mitral annulus calcification - \"The art of computer simulation\"","volume":"12","author":"Kar\u00e1dy","year":"2018","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2025100704360172000_105.Suppl_2.s21.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.05.064"},{"key":"2025100704360172000_105.Suppl_2.s21.13","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1016\/j.jtcvs.2014.05.071","article-title":"Is it possible to assess the best mitral valve repair in the individual patient? Preliminary results of a finite element study from magnetic resonance imaging data","volume":"148","author":"Sturla","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2025100704360172000_105.Suppl_2.s21.14","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s13239-016-0291-9","article-title":"Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation","volume":"8","author":"Pham","year":"2017","journal-title":"Cardiovasc Eng Technol"},{"key":"2025100704360172000_105.Suppl_2.s21.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2012.04.009"},{"key":"2025100704360172000_105.Suppl_2.s21.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2010.08.056"},{"key":"2025100704360172000_105.Suppl_2.s21.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.01.006"},{"key":"2025100704360172000_105.Suppl_2.s21.18","doi-asserted-by":"crossref","first-page":"2607","DOI":"10.1109\/TBME.2016.2645762","article-title":"A Regression Method Based on Noninvasive Clinical Data to Predict the Mechanical Behavior of Ascending Aorta Aneurysmal Tissue","volume":"64","author":"Auricchio","year":"2017","journal-title":"IEEE Trans Biomed Eng"},{"key":"2025100704360172000_105.Suppl_2.s21.19","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.medengphy.2017.06.045","article-title":"Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes","volume":"47","author":"Finotello","year":"2017","journal-title":"Med Eng Phys"},{"key":"2025100704360172000_105.Suppl_2.s21.20","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","article-title":"Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations","volume":"71","author":"Bosi","year":"2018","journal-title":"J Biomech"},{"key":"2025100704360172000_105.Suppl_2.s21.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2016.01.003"},{"key":"2025100704360172000_105.Suppl_2.s21.22","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.005344"},{"key":"2025100704360172000_105.Suppl_2.s21.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.10.026"},{"key":"2025100704360172000_105.Suppl_2.s21.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.05.008"},{"key":"2025100704360172000_105.Suppl_2.s21.25","doi-asserted-by":"crossref","first-page":"1852","DOI":"10.1007\/s10439-017-1828-2","article-title":"Design, analysis and testing of a novel mitral valve for transcatheter implantation","volume":"45","author":"Bozkurt","year":"2017","journal-title":"Ann Biomed Eng"},{"key":"2025100704360172000_105.Suppl_2.s21.26","unstructured":"Ferguson N . Civilization. The West and the Rest. UK: Penguin Random House Books, 2012."},{"key":"2025100704360172000_105.Suppl_2.s21.27","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1093\/oxfordjournals.eurheartj.a060238","article-title":"Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs","volume":"13","author":"Andersen","year":"1992","journal-title":"Eur Heart J"},{"key":"2025100704360172000_105.Suppl_2.s21.28","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000047200.36165.B8"},{"key":"2025100704360172000_105.Suppl_2.s21.29","doi-asserted-by":"crossref","unstructured":"Wassef A , Rodes-Cabau J , Liu Y , et al . The learning curve and annual procedure volume standards for optimum outcomes of transcatheter aortic valve replacement findings from an international registry JACC: cardiovascular intervention. 2018;11.","DOI":"10.1016\/j.jcin.2018.06.044"},{"key":"2025100704360172000_105.Suppl_2.s21.30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.04.075"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2018-313514","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T11:36:09Z","timestamp":1759836969000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2018-313514"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":30,"journal-issue":{"issue":"Suppl 2","published-online":{"date-parts":[[2019,3,7]]},"published-print":{"date-parts":[[2019,3]]}},"alternative-id":["10.1136\/heartjnl-2018-313514"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2018-313514","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}