{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T06:23:14Z","timestamp":1767853394346,"version":"3.49.0"},"reference-count":38,"publisher":"BMJ","issue":"Suppl 2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"accepted":{"date-parts":[[2018,11,28]]},"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:p>Aortic valve-in-valve is a less invasive alternative to surgical redo in the treatment of failed bioprosthetic valves. While only inoperable patients underwent the procedure before, operators currently offer it to those at lower risk and worldwide experience is in the thousands. Early mortality has diminished in recent analyses and improvements in symptoms and quality of life have been documented. Main considerations with aortic valve-in-valve include elevated postprocedural gradients, coronary obstruction and leaflet thrombosis. Risk factors for each of these adverse events have been described at length. Aortic valve-in-valve offers a safe and effective option in the management of failed bioprosthetic valves.<\/jats:p>","DOI":"10.1136\/heartjnl-2018-313517","type":"journal-article","created":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T14:35:25Z","timestamp":1551969325000},"page":"s38-s43","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":16,"title":["Transcatheter aortic valve replacement in failed surgical valves"],"prefix":"10.1136","volume":"105","clinical-trial-number":[{"clinical-trial-number":"nct02556203","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Matheus","family":"Simonato","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Surgery, Federal University of Sao Paulo, Sao Paulo, Sao Paulo, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danny","family":"Dvir","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University of Washington, Seattle, Washington, United States of America"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"2025092100453310000_105.Suppl_2.s38.1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.08.015"},{"key":"2025092100453310000_105.Suppl_2.s38.2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.117.030729"},{"key":"2025092100453310000_105.Suppl_2.s38.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.05.034"},{"key":"2025092100453310000_105.Suppl_2.s38.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2013.03.032"},{"key":"2025092100453310000_105.Suppl_2.s38.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2007.04.068"},{"key":"2025092100453310000_105.Suppl_2.s38.6","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1093\/ejcts\/ezx244","article-title":"Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"52","author":"Capodanno","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"2025092100453310000_105.Suppl_2.s38.7","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2014.7246"},{"key":"2025092100453310000_105.Suppl_2.s38.8","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21300"},{"key":"2025092100453310000_105.Suppl_2.s38.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.04.074"},{"key":"2025092100453310000_105.Suppl_2.s38.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.02.057"},{"key":"2025092100453310000_105.Suppl_2.s38.11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2017.03.018"},{"key":"2025092100453310000_105.Suppl_2.s38.12","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.112.104505"},{"key":"2025092100453310000_105.Suppl_2.s38.13","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/j.jtcvs.2009.04.067","article-title":"Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve","volume":"139","author":"Cohen","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2025092100453310000_105.Suppl_2.s38.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2005.05.055"},{"key":"2025092100453310000_105.Suppl_2.s38.15","doi-asserted-by":"crossref","unstructured":"Alnasser S , Cheema AN , Simonato M , et al . Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis. Circulation 2017;10.","DOI":"10.1161\/CIRCINTERVENTIONS.116.004392"},{"key":"2025092100453310000_105.Suppl_2.s38.16","doi-asserted-by":"crossref","first-page":"e397","DOI":"10.4244\/EIJ-D-17-00546","article-title":"Matched comparison of next- and early-generation balloon-expandable transcatheter heart valve implantations in failed surgical aortic bioprostheses","volume":"14","author":"Seiffert","year":"2018","journal-title":"EuroIntervention"},{"key":"2025092100453310000_105.Suppl_2.s38.17","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2009.225144"},{"key":"2025092100453310000_105.Suppl_2.s38.18","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehs003"},{"key":"2025092100453310000_105.Suppl_2.s38.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2017.08.039"},{"key":"2025092100453310000_105.Suppl_2.s38.20","doi-asserted-by":"crossref","first-page":"909","DOI":"10.4244\/EIJV12I7A149","article-title":"In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves","volume":"12","author":"Simonato","year":"2016","journal-title":"EuroIntervention"},{"key":"2025092100453310000_105.Suppl_2.s38.21","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2017-312422"},{"key":"2025092100453310000_105.Suppl_2.s38.22","doi-asserted-by":"crossref","unstructured":"Schaefer A , Deuschl F , Conradi L , et al . Valve-in-valve-in-valve: balloon expandable transcatheter heart valve in failing self-expandable transcatheter heart valve in deteriorated surgical bioprosthesis. Catheter Cardiovasc Interv 2018;10.doi:10.1002\/ccd.27797","DOI":"10.1002\/ccd.27797"},{"key":"2025092100453310000_105.Suppl_2.s38.23","doi-asserted-by":"crossref","unstructured":"Simonato M , Webb J , Kornowski R , et al . Transcatheter replacement of failed bioprosthetic valves: large multicenter assessment of the effect of implantation depth on hemodynamics after aortic valve-in-valve. Circ Cardiovasc Interv 2016;9.doi:10.1161\/CIRCINTERVENTIONS.115.003651","DOI":"10.1161\/CIRCINTERVENTIONS.115.003651"},{"key":"2025092100453310000_105.Suppl_2.s38.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.08.1529"},{"key":"2025092100453310000_105.Suppl_2.s38.25","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1016\/j.ijcard.2014.07.175","article-title":"Cracking the ring of Edwards Perimount bioprosthesis with ultrahigh pressure balloons prior to transcatheter valve in valve implantation","volume":"176","author":"Tanase","year":"2014","journal-title":"Int J Cardiol"},{"key":"2025092100453310000_105.Suppl_2.s38.26","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.115.002667"},{"key":"2025092100453310000_105.Suppl_2.s38.27","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.005216"},{"key":"2025092100453310000_105.Suppl_2.s38.28","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1016\/j.athoracsur.2017.04.007","article-title":"Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation","volume":"104","author":"Allen","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"2025092100453310000_105.Suppl_2.s38.29","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1007\/s11748-015-0559-2","article-title":"Early and late outcomes of AVR with aortic annular enlargement in octogenarian","volume":"63","author":"Okamoto","year":"2015","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"2025092100453310000_105.Suppl_2.s38.30","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1093\/eurheartj\/ehx455","article-title":"Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry","volume":"39","author":"Ribeiro","year":"2018","journal-title":"Eur Heart J"},{"key":"2025092100453310000_105.Suppl_2.s38.31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.01.066"},{"key":"2025092100453310000_105.Suppl_2.s38.32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2018.01.247"},{"key":"2025092100453310000_105.Suppl_2.s38.33","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.jcct.2016.09.004","article-title":"Computed tomography assessment for transcatheter aortic valve in valve implantation: the vancouver approach to predict anatomical risk for coronary obstruction and other considerations","volume":"10","author":"Blanke","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2025092100453310000_105.Suppl_2.s38.34","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1509233"},{"key":"2025092100453310000_105.Suppl_2.s38.35","doi-asserted-by":"crossref","first-page":"2383","DOI":"10.1016\/S0140-6736(17)30757-2","article-title":"Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study","volume":"389","author":"Chakravarty","year":"2017","journal-title":"The Lancet"},{"key":"2025092100453310000_105.Suppl_2.s38.36","doi-asserted-by":"crossref","unstructured":"Abdel-Wahab M , Simonato M , Latib A , et al . Clinical valve thrombosis after transcatheter aortic valve-in-valve implantation. Circ Cardiovasc Interv 2018.","DOI":"10.1161\/CIRCINTERVENTIONS.118.006730"},{"key":"2025092100453310000_105.Suppl_2.s38.37","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2011.05.032"},{"key":"2025092100453310000_105.Suppl_2.s38.38","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.03.011"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2018-313517","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T07:45:41Z","timestamp":1758440741000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2018-313517"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":38,"journal-issue":{"issue":"Suppl 2","published-online":{"date-parts":[[2019,3,7]]},"published-print":{"date-parts":[[2019,3]]}},"alternative-id":["10.1136\/heartjnl-2018-313517"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2018-313517","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}