{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T12:48:04Z","timestamp":1787748484082,"version":"build-2784847793"},"reference-count":24,"publisher":"BMJ","issue":"16","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"accepted":{"date-parts":[[2020,1,8]]},"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>The timing of onset and associated predictors of late new conduction disturbances (CDs) leading to permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI) are still unknown, however, essential for an early and safe discharge. This study aimed to investigate the timing of onset and associated predictors of late onset CDs in patients requiring PPI (LCP) following TAVI.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>We performed retrospective analysis of prospectively collected data from five large volume centres in Europe. Post-TAVI electrocardiograms and telemetry data were evaluated in patients with a PPI post-TAVI to identify the onset of new advanced CDs. Early onset CDs were defined as within 48 hours after procedure, and late onset CDs as after 48 hours. A total of 2804 patients were included for analysis. The PPI rate was 12%, of which 18% was due to late onset CDs (&gt;48 hours). Independent predictors for LCP were pre-existing non-specific intraventricular conduction delay, pre-existing right bundle branch block, self-expandable valves and predilation. At least one of these risk factors was present in 98% of patients with LCP. Patients with a balloon-expandable valve without predilation did not develop CDs requiring PPI after 48 hours.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Safe early discharge might be feasible in patients without CDs in the first 48 hours after TAVI if no risk factors for LCP are present.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/heartjnl-2019-315967","type":"journal-article","created":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T17:15:20Z","timestamp":1580490920000},"page":"1244-1251","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":19,"title":["Late onset of new conduction disturbances requiring permanent pacemaker implantation following TAVI"],"prefix":"10.1136","volume":"106","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3630-683X","authenticated-orcid":false,"given":"Nynke H M","family":"Kooistra","sequence":"first","affiliation":[{"name":"Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martijn S","family":"van Mourik","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Amsterdam UMC, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ram\u00f3n","family":"Rodr\u00edguez-Olivares","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ram\u00f3n y Cajal University Hospital, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander H","family":"Maass","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Medical Center Groningen, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0030-7427","authenticated-orcid":false,"given":"Vincent J","family":"Nijenhuis","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St Antonius hospital, Nieuwegein, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rik","family":"van der Werf","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Medical Center Groningen, Groningen, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jurrien M","family":"ten Berg","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St Antonius hospital, Nieuwegein, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adriaan O","family":"Kraaijeveld","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Baan Jr","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Amsterdam UMC, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michiel","family":"Voskuil","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Marije","family":"Vis","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Amsterdam UMC, Amsterdam, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pieter R","family":"Stella","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2020,1,31]]},"reference":[{"key":"2025092013320133000_106.16.1244.1","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"key":"2025092013320133000_106.16.1244.2","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N Engl J Med"},{"key":"2025092013320133000_106.16.1244.3","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","article-title":"Transcatheter or surgical aortic-valve replacement in intermediate-risk patients","volume":"374","author":"Leon","year":"2016","journal-title":"N Engl J Med"},{"key":"2025092013320133000_106.16.1244.4","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","article-title":"Surgical or transcatheter aortic-valve replacement in intermediate-risk patients","volume":"376","author":"Reardon","year":"2017","journal-title":"N Engl J Med"},{"key":"2025092013320133000_106.16.1244.5","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1093\/eurheartj\/ehx785","article-title":"Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review","volume":"39","author":"van Rosendael","year":"2018","journal-title":"Eur Heart J"},{"key":"2025092013320133000_106.16.1244.6","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1161\/CIRCULATIONAHA.117.028352","article-title":"Conduction disturbances after transcatheter aortic valve replacement: current status and future perspectives","volume":"136","author":"Auffret","year":"2017","journal-title":"Circulation"},{"key":"2025092013320133000_106.16.1244.7","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.jcin.2016.03.024","article-title":"The electrocardiogram after transcatheter aortic valve replacement determines the risk for post-procedural high-degree av block and the need for telemetry monitoring","volume":"9","author":"Toggweiler","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"2025092013320133000_106.16.1244.8","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jacc.2014.04.033","article-title":"Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis","volume":"64","author":"Siontis","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"2025092013320133000_106.16.1244.9","doi-asserted-by":"crossref","first-page":"555","DOI":"10.4244\/EIJV9I5A91","article-title":"Optimisation of transcatheter aortic balloon-expandable valve deployment: the two-step inflation technique","volume":"9","author":"Nijhoff","year":"2013","journal-title":"EuroIntervention"},{"key":"2025092013320133000_106.16.1244.10","doi-asserted-by":"crossref","unstructured":"Rubin DB , ed. Multiple imputation for nonresponse in surveys. Hoboken, NJ, USA: John Wiley & Sons, Inc, 1987.","DOI":"10.1002\/9780470316696"},{"key":"2025092013320133000_106.16.1244.11","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1093\/biomet\/69.1.239","article-title":"Partial residuals for the proportional hazards regression model","volume":"69","author":"Schoenfeld","year":"1982","journal-title":"Biometrika"},{"key":"2025092013320133000_106.16.1244.12","doi-asserted-by":"crossref","first-page":"85","DOI":"10.3389\/fcvm.2018.00085","article-title":"Tavi and post procedural cardiac conduction abnormalities","volume":"5","author":"Mangieri","year":"2018","journal-title":"Front Cardiovasc Med"},{"key":"2025092013320133000_106.16.1244.13","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ijcard.2018.07.131","article-title":"Delayed pacemaker requirement after transcatheter aortic valve implantation with a new-generation balloon expandable valve: should we monitor longer?","volume":"273","author":"De-Torres-Alba","year":"2018","journal-title":"Int J Cardiol"},{"key":"2025092013320133000_106.16.1244.14","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/j.jcin.2018.06.014","article-title":"Predictors of advanced conduction disturbances requiring a late (\u226548 H) permanent pacemaker following transcatheter aortic valve replacement","volume":"11","author":"Mangieri","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"2025092013320133000_106.16.1244.15","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.amjcard.2018.04.025","article-title":"Meta-analysis of the impact of avoiding balloon Predilation in transcatheter aortic valve implantation","volume":"122","author":"Banerjee","year":"2018","journal-title":"Am J Cardiol"},{"key":"2025092013320133000_106.16.1244.16","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1038\/nrcardio.2012.58","article-title":"New conduction abnormalities after TAVI--frequency and causes","volume":"9","author":"van der Boon","year":"2012","journal-title":"Nat Rev Cardiol"},{"key":"2025092013320133000_106.16.1244.17","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.jcin.2010.01.017","article-title":"Predictors for new-onset complete heart block after transcatheter aortic valve implantation","volume":"3","author":"Bleiziffer","year":"2010","journal-title":"JACC Cardiovasc Interv"},{"key":"2025092013320133000_106.16.1244.18","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.ahj.2012.07.028","article-title":"Cardiac conduction system disease after transcatheter aortic valve replacement","volume":"164","author":"Steinberg","year":"2012","journal-title":"Am Heart J"},{"key":"2025092013320133000_106.16.1244.19","first-page":"1663","article-title":"Transcatheter aortic valve implantation: know the differences between the currently available technologies","volume":"31","author":"MacDonald","year":"2010","journal-title":"Eur Heart J"},{"key":"2025092013320133000_106.16.1244.20","doi-asserted-by":"crossref","first-page":"2729","DOI":"10.1093\/eurheartj\/ehx295","article-title":"Final 5-year clinical and echocardiographic results for treatment of severe aortic stenosis with a self-expanding bioprosthesis from the advance study","volume":"38","author":"Gerckens","year":"2017","journal-title":"Eur Heart J"},{"key":"2025092013320133000_106.16.1244.21","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.jcin.2017.10.032","article-title":"Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement","volume":"11","author":"Chamandi","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"2025092013320133000_106.16.1244.22","doi-asserted-by":"crossref","first-page":"875","DOI":"10.4244\/EIJ-D-18-01060","article-title":"Pacemaker dependency after transcatheter aortic valve implantation: incidence, predictors and long-term outcomes","volume":"15","author":"Costa","year":"2019","journal-title":"EuroIntervention"},{"key":"2025092013320133000_106.16.1244.23","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacc.2019.08.632","article-title":"TCT-530 late onset of new conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve implantation","volume":"74","author":"Kooistra","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2025092013320133000_106.16.1244.24","doi-asserted-by":"crossref","unstructured":"Kooistra NHM , Van Mourik MS , Rodriguez-Olivares R , et al . P3856Timing and associated predictors of onset of new conduction disturbances requiring permanent pacemaker implantation after transcatheter aortic valve implantation. Eur Heart J 2019;40.doi:10.1093\/eurheartj\/ehz745.0694","DOI":"10.1093\/eurheartj\/ehz745.0694"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2019-315967","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T20:32:11Z","timestamp":1758400331000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2019-315967"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,31]]},"references-count":24,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2020,7,27]]},"published-print":{"date-parts":[[2020,8]]}},"alternative-id":["10.1136\/heartjnl-2019-315967"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2019-315967","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,31]]}}}