{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T13:06:03Z","timestamp":1795093563975,"version":"4.10.2"},"reference-count":30,"publisher":"BMJ","issue":"13","license":[{"start":{"date-parts":[[2022,3,21]],"date-time":"2022-03-21T00:00:00Z","timestamp":1647820800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Medtronic Poland Sp. z o.o."},{"name":"Cor Aegrum Foundation of Cardiac Surgery Development in Cracow"},{"name":"Jagiellonian University"},{"name":"Polish Ministry of Science and Higher Education"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>Current generation left ventricular assist devices (LVADs) operate with a fixed rotation speed and no automated speed adjustment function. This study evaluates the concept of physiological pump speed optimisation based on aortic valve opening (AVO) imaging during a cardiopulmonary exercise test (CPET).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This prospective crossover study (<jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"clintrialgov\" xlink:href=\"NCT05063006\">NCT05063006<\/jats:ext-link>) enrolled patients with implanted third-generation LVADs with hydrodynamic bearing. After resting speed optimisation, patients were randomised to a fixed-modified speed or modified-fixed speed CPET sequence. Fixed speed CPET maintained baseline pump settings. During the modified speed CPET, the LVAD speed was continuously altered to preserve periodic AVO.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>We included 22 patients, the mean age was 58.4\u00b17 years, 4.5% were women and 54.5% had ischaemic cardiomyopathy. Exertional AVO assessment was feasible in all subjects. Maintaining periodic AVO allowed to safely raise the pump speed from 2900 (IQR 2640\u20133000) to 3440 revolutions per minute (RPM) (IQR 3100\u20133700; p&lt;0.001). As a result, peak oxygen consumption increased from 11.1\u00b12.4\u2009to 12.8\u00b12.8\u2009mL\/kg\/min (p&lt;0.001) and maximum workload from 1.1 (IQR 0.9\u20131.5) to 1.2\u2009W\/kg (IQR 0.9\u20131.7; p=0.028). The Borg scale exertion level decreased from 15.2\u00b11.5\u2009to 13.5\u00b11.2 (p=0.005).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Transthoracic AVO imaging is possible during CPETs in patients with LVAD. Dynamic echo-guided pump speed adjustment based on the AVO improves exercise tolerance and augments peak oxygen consumption and maximum workload.<\/jats:p><\/jats:sec>","DOI":"10.1136\/heartjnl-2021-320495","type":"journal-article","created":{"date-parts":[[2022,3,21]],"date-time":"2022-03-21T17:25:41Z","timestamp":1647883541000},"page":"1055-1062","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":8,"title":["Echo-guided left ventricular assist device speed optimisation for exercise maximisation"],"prefix":"10.1136","volume":"108","clinical-trial-number":[{"clinical-trial-number":"nct05063006","registry":"10.18810\/clinical-trials-gov"},{"clinical-trial-number":"nct05063006","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0480-0729","authenticated-orcid":false,"given":"Maciej","family":"Stapor","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam","family":"Pilat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrzej","family":"Gackowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Agnieszka","family":"Misiuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Izabela","family":"Gorkiewicz-Kot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Kaleta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pawel","family":"Kleczynski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krzysztof","family":"Zmudka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacek","family":"Legutko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boguslaw","family":"Kapelak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karol","family":"Wierzbicki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2022,3,21]]},"reference":[{"key":"2023100108000733000_108.13.1055.1","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.athoracsur.2019.12.005","article-title":"The Society of Thoracic Surgeons Intermacs 2019 annual report: the changing landscape of devices and indications","volume":"109","author":"Teuteberg","year":"2020","journal-title":"Ann Thorac Surg"},{"key":"2023100108000733000_108.13.1055.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2014.12.006"},{"key":"2023100108000733000_108.13.1055.3","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.healun.2014.11.001","article-title":"Exercise in heart failure patients supported with a left ventricular assist device","volume":"34","author":"Jung","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"2023100108000733000_108.13.1055.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2019.10.013"},{"key":"2023100108000733000_108.13.1055.5","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.healun.2020.11.009","article-title":"Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices","volume":"40","author":"Tran","year":"2021","journal-title":"J Heart Lung Transplant"},{"key":"2023100108000733000_108.13.1055.6","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.120.007448","article-title":"Impairments in blood pressure regulation and cardiac baroreceptor sensitivity among patients with heart failure supported with continuous-flow left ventricular assist devices","volume":"14","author":"Sailer","year":"2021","journal-title":"Circ Heart Fail"},{"key":"2023100108000733000_108.13.1055.7","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1111\/aor.13349","article-title":"LVAD pump flow does not adequately increase with exercise","volume":"43","author":"Gross","year":"2019","journal-title":"Artif Organs"},{"key":"2023100108000733000_108.13.1055.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.07.052"},{"key":"2023100108000733000_108.13.1055.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2015.10.001"},{"key":"2023100108000733000_108.13.1055.10","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.cardfail.2015.06.010","article-title":"Left ventricular decompression during speed optimization RAMPs in patients supported by continuous-flow left ventricular assist devices: Device-Specific performance characteristics and impact on diagnostic algorithms","volume":"21","author":"Uriel","year":"2015","journal-title":"J Card Fail"},{"key":"2023100108000733000_108.13.1055.11","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1111\/aor.13569","article-title":"LVAD speed increase during exercise, which patients would benefit the most? A simulation study","volume":"44","author":"Gross","year":"2020","journal-title":"Artif Organs"},{"key":"2023100108000733000_108.13.1055.12","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.healun.2016.06.020","article-title":"Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients: a double-blind, randomized trial","volume":"36","author":"Jung","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"2023100108000733000_108.13.1055.13","doi-asserted-by":"publisher","DOI":"10.1002\/ejhf.52"},{"key":"2023100108000733000_108.13.1055.14","doi-asserted-by":"crossref","first-page":"S1802","DOI":"10.21037\/jtd.2018.01.114","article-title":"Effects of pump speed changes on exercise capacity in patients supported with a left ventricular assist device-an overview","volume":"10","author":"Schmidt","year":"2018","journal-title":"J Thorac Dis"},{"key":"2023100108000733000_108.13.1055.15","doi-asserted-by":"publisher","DOI":"10.1093\/eurjhf\/hfs042"},{"key":"2023100108000733000_108.13.1055.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2015.03.003"},{"key":"2023100108000733000_108.13.1055.17","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezw147"},{"key":"2023100108000733000_108.13.1055.18","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/MAT.0000000000000194","article-title":"Relation between pressure and volume unloading during ramp testing in patients supported with a continuous-flow left ventricular assist device","volume":"61","author":"Jung","year":"2015","journal-title":"Asaio J"},{"key":"2023100108000733000_108.13.1055.19","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.ijchv.2014.07.004","article-title":"Systemic perfusion at peak incremental exercise in left ventricular assist device recipients: partitioning pump and native left ventricle relative contribution","volume":"4","author":"Mezzani","year":"2014","journal-title":"IJC Heart & Vessels"},{"key":"2023100108000733000_108.13.1055.20","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.110.958041"},{"key":"2023100108000733000_108.13.1055.21","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1007\/s10439-016-1552-3","article-title":"Evaluation of physiological control systems for rotary left ventricular assist devices: an in-vitro study","volume":"44","author":"Pauls","year":"2016","journal-title":"Ann Biomed Eng"},{"key":"2023100108000733000_108.13.1055.22","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.compbiomed.2015.09.006","article-title":"ADRC or adaptive controller--A simulation study on artificial blood pump","volume":"66","author":"Wu","year":"2015","journal-title":"Comput Biol Med"},{"key":"2023100108000733000_108.13.1055.23","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/34\/1\/R1","article-title":"Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review","volume":"34","author":"AlOmari","year":"2013","journal-title":"Physiol Meas"},{"key":"2023100108000733000_108.13.1055.24","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezu006"},{"key":"2023100108000733000_108.13.1055.25","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0229688","article-title":"Hemodynamic exercise responses with a continuous-flow left ventricular assist device: comparison of patients' response and cardiorespiratory simulations","volume":"15","author":"Gross","year":"2020","journal-title":"PLoS One"},{"key":"2023100108000733000_108.13.1055.26","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1111\/aor.13381","article-title":"Beat-to-beat detection of aortic valve opening in HeartWare left ventricular assist device patients","volume":"43","author":"Clifford","year":"2019","journal-title":"Artif Organs"},{"key":"2023100108000733000_108.13.1055.27","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1109\/TBME.2015.2489188","article-title":"Continuous monitoring of aortic valve opening in rotary blood pump patients","volume":"63","author":"Granegger","year":"2016","journal-title":"IEEE Trans Biomed Eng"},{"key":"2023100108000733000_108.13.1055.28","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1111\/aor.12167","article-title":"Assessment of aortic valve opening during rotary blood pump support using pump signals","volume":"38","author":"Granegger","year":"2014","journal-title":"Artif Organs"},{"key":"2023100108000733000_108.13.1055.29","doi-asserted-by":"crossref","unstructured":"Vilkomerson D , Chilipka T , Bogan J . Implantable ultrasound devices. In: McAleavey SA , D\u2019hooge J , eds. Implantable ultrasound devices, 2008: 69200C.","DOI":"10.1117\/12.772845"},{"key":"2023100108000733000_108.13.1055.30","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.7863\/jum.2012.31.11.1795","article-title":"Development of a flexible implantable sensor for postoperative monitoring of blood flow","volume":"31","author":"Cannata","year":"2012","journal-title":"J Ultrasound Med"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2021-320495","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T15:02:00Z","timestamp":1696172520000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2021-320495"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,21]]},"references-count":30,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2022,6,10]]},"published-print":{"date-parts":[[2022,7]]}},"alternative-id":["10.1136\/heartjnl-2021-320495"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2021-320495","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,21]]}}}