{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T00:08:55Z","timestamp":1793837335381,"version":"4.6.1"},"reference-count":27,"publisher":"BMJ","issue":"12","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Heart"],"accepted":{"date-parts":[[2025,8,6]]},"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>False-positive (FP) alerts from implantable loop recorders increase clinical workload and may delay appropriate intervention. AccuRhythm AI, a cloud-based filtering algorithm, is designed to reduce these alerts in Reveal LINQ and LINQ II devices. This study assessed the algorithm\u2019s effect on FP and clinician burden reduction, with a focus on the influence of R-wave sensing amplitude.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This multicentre, retrospective study included 800 patients with either Reveal LINQ or LINQ II. We analysed automated artificial intelligence (AI) reports and compared FP rates and transmission burden before and after software-based AI activation in the subset of Reveal LINQ patients to assess patient-level changes. The relationship between R-wave amplitude and FP incidence was also evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>AI-based filtering, by AccuRhythm AI automatic analysis, reduced false pause alerts by 62% and false atrial fibrillation alerts by 33%, saving 210 clinician hours over 6\u2009months. Patient level analysis, among 465 Reveal LINQ patients, showed FP+ patients (patients with \u22651 false-positive transmission) reduction from 55.5% to 15.1% post-AI (p&lt;0.001), translating to 1128\u2009hours saved. All residual false alerts occurred in patients with R-wave amplitudes &lt;0.4\u2009mV.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Use of AccuRhythm AI was associated with a significant reduction in FPs and clinician workload while preserving diagnostic accuracy. R-wave amplitude remained a key factor influencing alert specificity, emphasising the continued importance of optimal device implantation and signal quality.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/heartjnl-2025-326430","type":"journal-article","created":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T17:20:22Z","timestamp":1756315222000},"page":"667-673","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Optimising implantable loop recorder alerts with artificial intelligence: role of R-wave amplitude and workload reduction"],"prefix":"10.1136","volume":"112","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-6604-1756","authenticated-orcid":false,"given":"Luigi","family":"Cocchiara","sequence":"first","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benedetta","family":"Brescia","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2677-9214","authenticated-orcid":false,"given":"Procolo","family":"Marchese","sequence":"additional","affiliation":[{"name":"EP Lab Cardiology, G e C Mazzoni Hospital, AST Ascoli Piceno, Marche, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Nardi","sequence":"additional","affiliation":[{"name":"Pineta Grande Srl, Castel Volturno, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianmarco","family":"Arabia","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Spedali Civili Hospital, Brescia, Lombardy, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfonsomaria","family":"Salucci","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Gennaro","sequence":"additional","affiliation":[{"name":"EP Lab Cardiology, G e C Mazzoni Hospital, AST Ascoli Piceno, Marche, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Mazzotta","sequence":"additional","affiliation":[{"name":"EP Lab Cardiology, G e C Mazzoni Hospital, AST Ascoli Piceno, Marche, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucio","family":"Addeo","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emiliano","family":"Calvi","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Spedali Civili Hospital, Brescia, Lombardy, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianfranco","family":"Mitacchione","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Spedali Civili Hospital, Brescia, Lombardy, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5928-1669","authenticated-orcid":false,"given":"Teresa","family":"Strisciuglio","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7751-6871","authenticated-orcid":false,"given":"Pasquale","family":"Vergara","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Esposito","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4739-7004","authenticated-orcid":false,"given":"Antonio","family":"Rapacciuolo","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Campania, Italy"},{"name":"Villa Betania Evangelical Hospital, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,8,27]]},"reference":[{"key":"2026052602101694000_112.12.667.1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehp298"},{"key":"2026052602101694000_112.12.667.2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(03)00659-4"},{"key":"2026052602101694000_112.12.667.3","doi-asserted-by":"publisher","DOI":"10.1161\/hc3601.095708"},{"key":"2026052602101694000_112.12.667.4","doi-asserted-by":"publisher","DOI":"10.1161\/hc4201.097837"},{"key":"2026052602101694000_112.12.667.5","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehi842"},{"key":"2026052602101694000_112.12.667.6","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euu412"},{"key":"2026052602101694000_112.12.667.7","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehae133"},{"key":"2026052602101694000_112.12.667.8","doi-asserted-by":"crossref","unstructured":"Letsas KP , Saplaouras A , Mililis P , et al . Diagnostic yield of implantable loop recorders: results from the hellenic registry. Hellenic J Cardiol 2024;8. doi:10.1016\/j.hjc.2024.05.004","DOI":"10.1016\/j.hjc.2024.05.004"},{"key":"2026052602101694000_112.12.667.9","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(21)01698-6"},{"key":"2026052602101694000_112.12.667.10","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2008.01156.x"},{"key":"2026052602101694000_112.12.667.11","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.joa.2014.09.005","article-title":"Investigation of optimal position for implantable loop recorders by potential mapping with Reveal DX","volume":"31","author":"Kawashima","year":"2015","journal-title":"J Arrhythm"},{"key":"2026052602101694000_112.12.667.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2023.03.1525"},{"key":"2026052602101694000_112.12.667.13","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1111\/pace.14941","article-title":"False-positive alarms in patients with implantable loop recorder followed by remote monitoring: A systematic review","volume":"47","author":"Covino","year":"2024","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026052602101694000_112.12.667.14","doi-asserted-by":"crossref","DOI":"10.2196\/27720","article-title":"Clinic Time Required for Remote and In-Person Management of Patients With Cardiac Devices: Time and Motion Workflow Evaluation","volume":"5","author":"Seiler","year":"2021","journal-title":"JMIR Cardio"},{"key":"2026052602101694000_112.12.667.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.08.029"},{"key":"2026052602101694000_112.12.667.16","unstructured":"AI clinician manual supplements m040455c001a and m032522c001b. Medtronic. n.d. Available: https:\/\/manuals.medtronic.com\/manuals"},{"key":"2026052602101694000_112.12.667.17","doi-asserted-by":"crossref","first-page":"S293","DOI":"10.1016\/j.hrthm.2021.06.732","article-title":"B-PO04-036 Innovative Artificial Intelligence Application Reduces False Pause Alerts while Maintaining Perfect True Pause Sensitivity for Insertable Cardiac Monitors","volume":"18","author":"Cheng","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026052602101694000_112.12.667.18","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacadv.2025.101656","article-title":"Impact of Artificial Intelligence-Enhanced Insertable Cardiac Monitors on Device Clinic Workflow and Resource Utilization","volume":"4","author":"Katapadi","year":"2025","journal-title":"JACC Adv"},{"key":"2026052602101694000_112.12.667.19","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2024.1343424","article-title":"Implantable cardiac monitors: artificial intelligence and signal processing reduce remote ECG review workload and preserve arrhythmia detection sensitivity","volume":"11","author":"Bisignani","year":"2024","journal-title":"Front Cardiovasc Med"},{"key":"2026052602101694000_112.12.667.20","doi-asserted-by":"crossref","first-page":"S47","DOI":"10.1016\/j.hrthm.2021.06.137","article-title":"B-AB24-04 Artificial intelligence enables dramatic reduction of false atrial fibrillation alerts from insertable cardiac monitors","volume":"18","author":"Radtke","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026052602101694000_112.12.667.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.12.006"},{"key":"2026052602101694000_112.12.667.22","doi-asserted-by":"crossref","unstructured":"Rosier A , Crespin E , Lazarus A , et al . A novel machine learning algorithm has the potential to reduce by 1\/3 the quantity of ILR episodes needing review. Eur Heart J 2021;42. doi:10.1093\/eurheartj\/ehab724.0316","DOI":"10.1093\/eurheartj\/ehab724.0316"},{"key":"2026052602101694000_112.12.667.23","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1016\/S0735-1097(22)02999-0","article-title":"The application of a novel AI-based algorithm in implantable loop recorders, reduction in false positive atrial arrhythmia event episodes without impacting time to first event detection","volume":"79","author":"Crespin","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"2026052602101694000_112.12.667.24","doi-asserted-by":"crossref","unstructured":"Varma N , Marijon E , Vicaut \u00c9 , et al . Impact of a universal monitoring system (\u201cthird party\u201d) on outcomes of ICD patients: A nationwide study. Heart Rhythm 2024. doi:10.1016\/j.hrthm.2024.11.029","DOI":"10.1016\/j.hrthm.2024.11.029"},{"key":"2026052602101694000_112.12.667.25","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jelectrocard.2021.08.009","article-title":"Performance of implantable loop recorders. Role of R vector and detection algorithms","volume":"68","author":"Kremer","year":"2021","journal-title":"J Electrocardiol"},{"key":"2026052602101694000_112.12.667.26","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1111\/pace.14851","article-title":"Remote monitoring of implantable cardiac monitors in patients with unexplained syncope: Predictors of false-positive alert episodes","volume":"46","author":"Russo","year":"2023","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026052602101694000_112.12.667.27","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.hrthm.2024.07.025","article-title":"Revised protocol for loop recorder implant, maximizing R-wave amplitude minimizes false-positive alarms","volume":"22","author":"Cocchiara","year":"2025","journal-title":"Heart Rhythm"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/heartjnl-2025-326430","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T19:03:52Z","timestamp":1779822232000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/heartjnl-2025-326430"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,27]]},"references-count":27,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2026,5,26]]},"published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1136\/heartjnl-2025-326430"],"URL":"https:\/\/doi.org\/10.1136\/heartjnl-2025-326430","relation":{},"ISSN":["1355-6037","1468-201X"],"issn-type":[{"value":"1355-6037","type":"print"},{"value":"1468-201X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,27]]}}}