{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T03:16:47Z","timestamp":1761016607992},"reference-count":24,"publisher":"BMJ","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Heart"],"published-print":{"date-parts":[[1992,8,1]]},"DOI":"10.1136\/hrt.68.8.223","type":"journal-article","created":{"date-parts":[[2007,9,18]],"date-time":"2007-09-18T21:46:00Z","timestamp":1190151960000},"page":"223-229","source":"Crossref","is-referenced-by-count":13,"title":["Validation of the beat to beat measurement of blood velocity in the human ascending aorta by a new high temporal resolution Doppler ultrasound spectral analyser"],"prefix":"10.1136","volume":"68","author":[{"given":"A J S","family":"Coats","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C","family":"Murphy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J","family":"Conway","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P","family":"Sleight","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","reference":[{"key":"ref_1","article-title":"Doppler ultrasound in cardiology. Philadelphia: Lea and Feibiger","author":"Hatle, L.; Angelsen, B.","year":"1985","unstructured":"Hatle L, Angelsen B. Doppler ultrasound in cardiology. Philadelphia: Lea and Feibiger, 1985."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/0141-5425(88)90087-8","article-title":"Doppler ultrasound signal analysis based on the TMS320 signal processor","volume":"10","author":"Murphy, C.; Coats, A.; Conway, J.; Colditz, P.; Rolphe, P.","year":"1988","unstructured":"Murphy C, Coats A, Conway J, Colditz P, Rolphe P. Doppler ultrasound signal analysis based on the TMS320 signal processor. J Biomed Eng 1988; 10: 127-9.","journal-title":"J Biomed Eng"},{"key":"ref_3","first-page":"721","article-title":"Effects of antihypertensive agents on blood velocity: implications for atherogenesis","volume":"127","author":"Spence, J.D.","year":"1982","unstructured":"Spence JD. Effects of antihypertensive agents on blood velocity: implications for atherogenesis. Can Med Assoc J 1982;127:721-4.","journal-title":"Can Med Assoc J"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1161\/01.HYP.15.4.339","article-title":"Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension","volume":"15","author":"O'Rourke, M.","year":"1990","unstructured":"O'Rourke M. Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension. Hypertension 1990;15:339-47.","journal-title":"Hypertension"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1161\/01.CIR.29.2.268","article-title":"Initial ventricular impulse-a potential key to cardiac evaluation","volume":"29","author":"Rushmer, R.F.","year":"1964","unstructured":"Rushmer RF. Initial ventricular impulse-a potential key to cardiac evaluation. Circulation 1964;29:268-83.","journal-title":"Circulation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1016\/0002-8703(88)90455-3","article-title":"Hemodynamic response to treadmill exercise in normal volunteers: an assessment by Doppler ultrasonic measurement of ascending aortic blood velocity and acceleration","volume":"116","author":"Mehta, N.; Boyle, G.; Bennett, D.","year":"1988","unstructured":"Mehta N, Boyle G, Bennett D, et al. Hemodynamic response to treadmill exercise in normal volunteers: an assessment by Doppler ultrasonic measurement of ascending aortic blood velocity and acceleration. Am Heart J 1988; 116:1298-307.","journal-title":"Am Heart J"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/0002-8703(87)90048-2","article-title":"Peak aortic blood acceleration reflects the extent of left ventricular ischemic mass at risk","volume":"113","author":"Sabbah, H.N.; Przybylski, J.; Albert, D.E.; Stein, P.D.","year":"1987","unstructured":"Sabbah HN, Przybylski J, Albert DE, Stein PD. Peak aortic blood acceleration reflects the extent of left ventricular ischemic mass at risk. Am Heart J 1987;113:885-90.","journal-title":"Am Heart J"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1093\/cvr\/19.7.383","article-title":"Quantitative ascending aortic Doppler blood velocity in normal human subjects","volume":"19","author":"Levy, B.; Targett, R.C.; Bardou, A.; McIlroy, M.B.","year":"1985","unstructured":"Levy B, Targett RC, Bardou A, McIlroy MB. Quantitative ascending aortic Doppler blood velocity in normal human subjects. Cardiovasc Res 1985;19:383-93.","journal-title":"Cardiovasc Res"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1093\/cvr\/19.7.394","article-title":"Simultaneous Doppler blood velocity measurements from aorta and radial artery in normal human subjects","volume":"19","author":"Targett, R.C.; Levy, B.; Bardou, A.; McIlroy, M.B.","year":"1985","unstructured":"Targett RC, Levy B, Bardou A, McIlroy MB. Simultaneous Doppler blood velocity measurements from aorta and radial artery in normal human subjects. Cardiovasc Res 1985;19:394-9.","journal-title":"Cardiovasc Res"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1093\/cvr\/21.1.72","article-title":"Validation of beat by beat pulsed Doppler measurements of ascending aortic blood velocity in man","volume":"21","author":"Innes, J.A.; Mills, C.J.; Noble, M.I.M.","year":"1987","unstructured":"Innes JA, Mills CJ, Noble MIM, et al. Validation of beat by beat pulsed Doppler measurements of ascending aortic blood velocity in man. Cardiovasc Res 1987;21:72-80.","journal-title":"Cardiovasc Res"},{"key":"ref_11","article-title":"Signal processing of Doppler ultrasound for the measurement ofbloodflow fD Phil Thesis 1","author":"Murphy, C.","year":"1988","unstructured":"Murphy C. Signal processing of Doppler ultrasound for the measurement ofbloodflow fD Phil Thesis 1. Oxford: Oxford University, 1988."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1161\/01.CIR.76.3.539","article-title":"Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution","volume":"76","author":"Christie, J.; Sheldahl, L.M.; Tristani, F.E.; Sagar, K.B.; Ptacin, M.J.; Wann, S.","year":"1987","unstructured":"Christie J, Sheldahl LM, Tristani FE, Sagar KB, Ptacin MJ, Wann S. Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution. Circulation 1987;76:539-47.","journal-title":"Circulation"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1136\/hrt.51.1.54","article-title":"Determination of cardiac output by Doppler echocardiography","volume":"51","author":"Ihlen, H.; Amlie, J.P.; Dale, J.","year":"1984","unstructured":"Ihlen H, Amlie JP, Dale J, et al. Determination of cardiac output by Doppler echocardiography. Br Heart J 1984; 51:54-60.","journal-title":"Br Heart J"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/S0735-1097(85)80255-2","article-title":"Superiority of two-dimensional measurement ofaortic vessel diameter in Doppler echocardiographic estimates of left ventricular stroke volume","volume":"6","author":"Gardin, J.M.; Tobis, J.M.; Dabestani, A.","year":"1985","unstructured":"Gardin JM, Tobis JM, Dabestani A, et al. Superiority of two-dimensional measurement ofaortic vessel diameter in Doppler echocardiographic estimates of left ventricular stroke volume. J Am Coll Cardiol 1985;6:66-74.","journal-title":"J Am Coll Cardiol"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"i:","author":"Bland, J.M.; Altman, D.G.","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;i:307-10.","journal-title":"Lancet"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1136\/hrt.55.1.14","article-title":"Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers","volume":"55","author":"Mackenzie, J.D.; Haites, N.E.; Rawles, J.M.","year":"1986","unstructured":"Mackenzie JD, Haites NE, Rawles JM. Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers. Br Heart J 1986;55:14-24.","journal-title":"Br Heart J"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/0002-8703(75)90506-2","article-title":"Transcutaneous determination of aortic blood flow velocities in man","volume":"89","author":"Huntsman, L.L.; Gams, E.; Johnson, C.C.; Fairbanks, E.","year":"1975","unstructured":"Huntsman LL, Gams E, Johnson CC, Fairbanks E. Transcutaneous determination of aortic blood flow velocities in man. Am Heart J 1975;89:605-12.","journal-title":"Am Heart J"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/0002-9149(84)90718-5","article-title":"Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computer","volume":"53","author":"Chandraratna, P.A.; Nanna, M.; McKay, C.","year":"1984","unstructured":"Chandraratna PA, Nanna M, McKay C, et al. Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computer. Am J Cardiol 1984;53: 234-7.","journal-title":"Am J Cardiol"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/S0002-9149(84)80151-4","article-title":"Accuracy of determination of changes in cardiac output by transcutaneous continuouswave Doppler computer","volume":"54","author":"Rose, J.S.; Nanna, M.; Rahimtoola, S.H.; Elkayam, U.; McKay, C.; Chandraratna, P.A.N.","year":"1984","unstructured":"Rose JS, Nanna M, Rahimtoola SH, Elkayam U, McKay C, Chandraratna PAN. Accuracy of determination of changes in cardiac output by transcutaneous continuouswave Doppler computer. Am J Cardiol 1984;54:1099-101.","journal-title":"Am J Cardiol"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1161\/01.CIR.70.3.425","article-title":"Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window","volume":"70","author":"Lewis, J.F.; Kuo, L.C.; Nelson, J.G.; Limacher, M.C.; Quinones, M.A.","year":"1984","unstructured":"Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 1984;70:425-31.","journal-title":"Circulation"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/0002-8703(85)90602-7","article-title":"The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output","volume":"109","author":"Labovitz, A.J.; Buckingham, T.A.; Habermehl, K.; Nelson, J.; Kennedy, H.L.; Williams, G.A.","year":"1985","unstructured":"Labovitz AJ, Buckingham TA, Habermehl K, Nelson J, Kennedy HL, Williams GA. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J 1985;109:327-32.","journal-title":"Am Heart J"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1093\/cvr\/21.4.260","article-title":"Pulsed Doppler ultrasound compared with thermodilution for monitoring cardiac output responses to changing left ventricular function","volume":"21","author":"Bojanowski, L.M.R.; Timmis, A.D.; Najm, Y.C.; Gosling, R.G.","year":"1987","unstructured":"Bojanowski LMR, Timmis AD, Najm YC, Gosling RG. Pulsed Doppler ultrasound compared with thermodilution for monitoring cardiac output responses to changing left ventricular function. Cardiovasc Res 1987;21:260-8.","journal-title":"Cardiovasc Res"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/0735-1097(89)90552-4","article-title":"Accuracy of cardiac output measured by continuous wave Doppler echocardiography during dynamic exercise testing in the supine position in patients with coronary artery disease","volume":"13","author":"Maeda, M.; Yokota, M.; Iwase, M.; Miyahara, T.; Hayashi, H.; Sotobata, I.","year":"1989","unstructured":"Maeda M, Yokota M, Iwase M, Miyahara T, Hayashi H, Sotobata I. Accuracy of cardiac output measured by continuous wave Doppler echocardiography during dynamic exercise testing in the supine position in patients with coronary artery disease. J Am Coll Cardiol 1989; 13:76-83.","journal-title":"J Am Coll Cardiol"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/S0735-1097(85)80127-3","article-title":"Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations","volume":"6","author":"Stewart, W.J.; Jiang, L.; Mich, R.; Pandian, N.; Guerrero, J.L.; Weyman, A.E.","year":"1985","unstructured":"Stewart WJ, Jiang L, Mich R, Pandian N, Guerrero JL, Weyman AE. Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations. J Am Coll Cardiol 1985;6:653-62.","journal-title":"J Am Coll Cardiol"}],"container-title":["Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/hrt.68.8.223","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T01:02:19Z","timestamp":1601082139000},"score":1,"resource":{"primary":{"URL":"https:\/\/heart.bmj.com\/lookup\/doi\/10.1136\/hrt.68.8.223"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,8,1]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[1992,8,1]]}},"URL":"https:\/\/doi.org\/10.1136\/hrt.68.8.223","relation":{},"ISSN":["1355-6037"],"issn-type":[{"value":"1355-6037","type":"print"}],"subject":[],"published":{"date-parts":[[1992,8,1]]}}}