{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T05:18:26Z","timestamp":1765603106703,"version":"3.48.0"},"reference-count":22,"publisher":"BMJ","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Clin Pathol"],"published-print":{"date-parts":[[1974,8]]},"abstract":"<jats:p>A modification of the test for EB virus\/IgM introduced by Schmitz and Scherer (1972) is described. It is simple and gives reproducible results.<\/jats:p>\n                  <jats:p>EB virus\/IgM was demonstrated in all but one case of infectious mononucleosis and in students with minor illness shown to have acquired EB virus\/IgG recently. Unlike the EB virus\/IgG, the IgM disappears within a few months. Although the Paul-Bunnell-Davidsohn test is still the test of choice for the diagnosis of infectious mononucleosis, the EB virus\/IgM test could be useful to establish a diagnosis of current or recent EB virus infection where the Paul-Bunnell-Davidsohn test was negative or equivocal.<\/jats:p>","DOI":"10.1136\/jcp.27.8.647","type":"journal-article","created":{"date-parts":[[2007,6,9]],"date-time":"2007-06-09T00:50:46Z","timestamp":1181350246000},"page":"647-651","source":"Crossref","is-referenced-by-count":36,"title":["Studies on the diagnostic value of an immunofluorescence test for EB virus-specific IgM"],"prefix":"10.1136","volume":"27","author":[{"given":"Joan M. B.","family":"Edwards","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. A.","family":"McSwiggan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[1974,8,1]]},"reference":[{"key":"ref_1","article-title":"Students who have an EB virus IgG-positive IgG, IgA, and IgM Brucella antibodies when examtitre on entry to the university can be assumed to ined by the method previously described for have been infected with EB virus before arrival. Can standardization of antihuman FITC conjugates an EB virus IgM ever be detected at a later date","volume-title":"using monospecific conjugates","year":"1969","unstructured":"Students who have an EB virus IgG-positive IgG, IgA, and IgM Brucella antibodies when examtitre on entry to the university can be assumed to ined by the method previously described for have been infected with EB virus before arrival. Can standardization of antihuman FITC conjugates an EB virus IgM ever be detected at a later date (Edwards, 1969) using monospecific conjugates."},{"key":"ref_2","article-title":"Automatic Dispensing Pipettes: an assessment of 35 commercial instruments","author":"BROUGHTON, P.M.G.; GOWENLOCK, A.H.; WIDDOWSON, G.M.; A, K.","year":"1967","unstructured":"Automatic Dispensing Pipettes: an assessment of 35 commercial instruments September 1967 P. M. G. BROUGHTON, A. H. GOWENLOCK, G. M. WIDDOWSON, and K. A. AHLQUIST"},{"key":"ref_3","article-title":"An Evaluation of five Commercial Flame Photometers suitable for the Simultaneous Determination of Sodium and Potassium","author":"BROUGHTON, P.M.G.","year":"1970","unstructured":"An Evaluation of five Commercial Flame Photometers suitable for the Simultaneous Determination of Sodium and Potassium March 1970 P. M. G. BROUGHTON and J. B. DAWSON"},{"key":"ref_4","article-title":"The Assessment of Thyroid Function","author":"FLYNN, F.V.; R, J.","year":"1971","unstructured":"The Assessment of Thyroid Function March 1971 F. V. FLYNN and J. R. HOBBS","journal-title":"HOBBS"},{"article-title":"Renal Function Tests Suitable for Clinical Practice January 1972 F","author":"MITCHELL, L.","key":"ref_5","unstructured":"Renal Function Tests Suitable for Clinical Practice January 1972 F. L. MITCHELL, N. VEALL, and R. W. E."},{"article-title":"Determination of Urea by AutoAnalyzer November 1966 RUTH M","volume-title":"HASLAM","key":"ref_6","unstructured":"Determination of Urea by AutoAnalyzer November 1966 RUTH M. HASLAM"},{"article-title":"Determination of Serum Albumin by AutoAnalyzer using Bromocresol Green October 1967 B","author":"NORTHAM, E.","key":"ref_7","unstructured":"Determination of Serum Albumin by AutoAnalyzer using Bromocresol Green October 1967 B E. NORTHAM and G. M. WIDDOWSON"},{"key":"ref_8","article-title":"An Assessment of the Technicon Type II Sampler Unit","author":"GRAY, B.C.","year":"1968","unstructured":"An Assessment of the Technicon Type II Sampler Unit March 1968 B. C. GRAY and G. K. MCGOWAN"},{"key":"ref_9","article-title":"Atomic Absorption Spectroscopy: an outline of its principles and a guide to the selection of instruments","author":"DAWSON, J.B.","year":"1968","unstructured":"Atomic Absorption Spectroscopy: an outline of its principles and a guide to the selection of instruments May 1968 J. B. DAWSON and P. M. G. BROUGHTON"},{"key":"ref_10","article-title":"A Guide to Automatic Pipettes","author":"G, P.M.","year":"1968","unstructured":"A Guide to Automatic Pipettes (2nd edition) June 1968 P. M. G. BROUGHTON","edition":"2nd edition"},{"key":"ref_11","first-page":"P.","article-title":"Flame Photometers: a comparative list of 17 instruments readily available","volume-title":"Britain August","year":"1969","unstructured":"Flame Photometers: a comparative list of 17 instruments readily available in Britain August 1969 P."},{"key":"ref_12","article-title":"Quantities and Units in Clinical Biochemistry","author":"G, P.M.","year":"1970","unstructured":"Quantities and Units in Clinical Biochemistry June 1970 P. M. G. BROUGHTON"},{"key":"ref_13","unstructured":"Filter Fluorimeters: A comparative list of 18 instruments September 1970 H. BRAUNSBERG and s. s. BROWN","article-title":"Filter Fluorimeters: A comparative list of 18 instruments September 1970 H. BRAUNSBERG and s. s"},{"article-title":"Bilirubin Standards and the Determination of Bilirubin by Manual and Technicon AutoAnalyzer Methods January 1971 BARBARA","author":"BILLING, R.U.T.H.H.A.S.L.A.M.","key":"ref_14","unstructured":"Bilirubin Standards and the Determination of Bilirubin by Manual and Technicon AutoAnalyzer Methods January 1971 BARBARA BILLING, RUTH HASLAM, and N. WALD"},{"key":"ref_15","unstructured":"Interchangeable Cells for Spectrophotometers and Fluorimeters September 1971 s. s. BROWN and A. H. GOWENLOCK","article-title":"Interchangeable Cells for Spectrophotometers and Fluorimeters September 1971 s. s. BROWN and A"},{"key":"ref_16","article-title":"Simple Tests to Detect Poisons","author":"W, B.","year":"1972","unstructured":"Simple Tests to Detect Poisons March 1972 B. W. MEADE et al.","journal-title":"MEADE et al"},{"key":"ref_17","unstructured":"Blood Gas Analysers May 1972 K. DIXON","article-title":"Blood Gas Analysers May 1972 K"},{"article-title":"Kits for Enzyme Activity Determination September 1972 s. B. ROSALKI and D","volume-title":"TARLOW","key":"ref_18","unstructured":"Kits for Enzyme Activity Determination September 1972 s. B. ROSALKI and D. TARLOW"},{"journal-title":"et al","article-title":"Assessment of Pumps Suitable for Incorporation into Existing Continuous Flow Analytical Systems November 1972 A FLECK","key":"ref_19","unstructured":"Assessment of Pumps Suitable for Incorporation into Existing Continuous Flow Analytical Systems November 1972 A FLECK et al."},{"article-title":"Routine Clinical Measurements of Transferrin in Human Serum September 1973 K","volume-title":"DIXON","key":"ref_20","unstructured":"Routine Clinical Measurements of Transferrin in Human Serum September 1973 K. DIXON"},{"key":"ref_21","article-title":"Control Materials for Clinical Biochemistry","year":"1973","unstructured":"Control Materials for Clinical Biochemistry (5th editicn) September 1973 J. F. STEVENS","edition":"5th editicn"},{"key":"ref_22","unstructured":"Notes on the Quallty of Performance of Serum Cholesterol Assays September 1973 s. s. BROWN","article-title":"Notes on the Quallty of Performance of Serum Cholesterol Assays September 1973 s. s"}],"container-title":["Journal of Clinical Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jcp.27.8.647","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T05:16:46Z","timestamp":1765603006000},"score":1,"resource":{"primary":{"URL":"https:\/\/jcp.bmj.com\/lookup\/doi\/10.1136\/jcp.27.8.647"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1974,8]]},"references-count":22,"journal-issue":{"issue":"8","published-online":{"date-parts":[[1974,8,1]]},"published-print":{"date-parts":[[1974,8]]}},"alternative-id":["10.1136\/jcp.27.8.647"],"URL":"https:\/\/doi.org\/10.1136\/jcp.27.8.647","relation":{},"ISSN":["0021-9746","1472-4146"],"issn-type":[{"type":"print","value":"0021-9746"},{"type":"electronic","value":"1472-4146"}],"subject":[],"published":{"date-parts":[[1974,8]]}}}