{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,7]],"date-time":"2025-12-07T02:00:39Z","timestamp":1765072839633,"version":"3.46.0"},"reference-count":27,"publisher":"BMJ","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Clin Pathol"],"published-print":{"date-parts":[[1982,3]]},"abstract":"<jats:p>The possible use of sodium hypochlorite solution buffered to pH 7.6 and containing 100 ppm available chlorine (avCl) for disinfecting fibrescopes was investigated. A flexible fibrescope experimentally contaminated with Pseudomonas putida, Mycobacterium fortuitum, or Bacillus subtilis spores was effectively disinfected within 10 m in repeatedly and without any observable adverse effect on the instrument. The corrosive nature of buffered hypochlorite was investigated by immersing various fibrescope components and metal wires in solutions of different strength for long periods and examining them for damage. Stainless steel, platinum, glass, Teflon, polythene and epoxy resin were apparently unaffected whereas polyurethane, rubber and other metals tested were damaged to different extents. Buffered hypochlorite solutions may have many applications pertaining to the disinfection of items which are either thermolabile or require rapid effective disinfection.<\/jats:p>","DOI":"10.1136\/jcp.35.3.296","type":"journal-article","created":{"date-parts":[[2007,6,9]],"date-time":"2007-06-09T00:50:46Z","timestamp":1181350246000},"page":"296-303","source":"Crossref","is-referenced-by-count":5,"title":["Use of buffered hypochlorite solution for disinfecting fibrescopes."],"prefix":"10.1136","volume":"35","author":[{"given":"D","family":"Coates","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J E","family":"Death","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[1982,3,1]]},"reference":[{"issue":"951-8","key":"ref_1","first-page":"656","article-title":"Ethylene oxide gas sterilisation","volume":"18","author":"Lancet","year":"1973","unstructured":"Ethylene oxide gas sterilisation. Am J Dig Dis 1973;18:951-8. 2 Axon ATR, Cotton PB, Phillips 1, Avery SA. Disinfection of gastrointestinal fibre endoscopes. Lancet 1974;i:656-8.","journal-title":"Am J Dig Dis; Disinfection of gastrointestinal fibre endoscopes"},{"key":"ref_2","first-page":"761","article-title":"Care and cleansing of the fiberoptic bronchoscope Chest","volume":"73","author":"Elford, B.","year":"1978","unstructured":"Elford B. Care and cleansing of the fiberoptic bronchoscope Chest 1978;73, suppl: 761-3."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1136\/jcp.27.8.632","article-title":"Sporicidal activity of hospital disinfectants","volume":"27","author":"Kelsey, J.C.; MacKinnon, I.H.; Maurer, I.M.","year":"1974","unstructured":"Kelsey JC, MacKinnon IH, Maurer IM. Sporicidal activity of hospital disinfectants. J Clin Pathol 1974;27: 632-8.","journal-title":"J Clin Pathol"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1136\/jcp.31.2.148","article-title":"Sporicidal activity of mixtures of alcohol and hypochlorite","volume":"31","author":"Coates, D.; Death, J.E.","year":"1978","unstructured":"Coates D, Death JE. Sporicidal activity of mixtures of alcohol and hypochlorite. J Clin Pathol 1978;31:148-52.","journal-title":"J Clin Pathol"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1136\/jcp.32.2.148","article-title":"Effect of pH on sporicidal and microbicidal activity of buffered mixtures of alcohol and sodium hypochlorite","volume":"32","author":"Death, J.E.; Coates, D.","year":"1979","unstructured":"Death JE, Coates D. Effect of pH on sporicidal and microbicidal activity of buffered mixtures of alcohol and sodium hypochlorite. J Clin Pathol 1979;32:148-53.","journal-title":"J Clin Pathol"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1111\/j.1365-2672.1965.tb02163.x","article-title":"A bacterial spore test piece for the control of ethylene oxide sterilization","volume":"28","author":"Beeby, M.M.; Whitehouse, C.E.","year":"1965","unstructured":"Beeby MM, Whitehouse CE. A bacterial spore test piece for the control of ethylene oxide sterilization. J Appl Bacteriol 1965;28:349-60.","journal-title":"J Appl Bacteriol"},{"key":"ref_7","article-title":"Sporicidal activity of alcohol-hypochlorite mixtures and hypochlorite solutions with particular reference to fibre-optic endoscope disinfection. PhD thesis","author":"Death, J.E.","year":"1979","unstructured":"Death JE. Sporicidal activity of alcohol-hypochlorite mixtures and hypochlorite solutions with particular reference to fibre-optic endoscope disinfection. PhD thesis. Guildford: University of Surrey, 1979."},{"key":"ref_8","first-page":"402","article-title":"Kelsey-Sykes capacity test: origin, evolution and current status","volume":"219","author":"Coates, D.","year":"1977","unstructured":"Coates D. Kelsey-Sykes capacity test: origin, evolution and current status. Pharmaceutical J 1977;219:402-3.","journal-title":"Pharmaceutical J"},{"issue":"38","key":"ref_9","first-page":"732","article-title":"The estimation of the bactericidal power of the blood","volume":"1938","author":"Miles, A.A.; Misra, S.S.; Irwin, J.O.","unstructured":"Miles AA, Misra SS, Irwin JO. The estimation of the bactericidal power of the blood. J Hyg 1938;38:732-49.","journal-title":"J Hyg"},{"key":"ref_10","first-page":"59","article-title":"Fever and pneumonia after flexible fiberoptic bronchoscopy","volume":"112","year":"1975","unstructured":"Pereira W, Kovnat DM, Anees Khan M, lacovino JR, Spivack ML, Snider GL. Fever and pneumonia after flexible fiberoptic bronchoscopy. Am Rev Respir Dis 1975;112:59-64.","journal-title":"Am Rev Respir Dis"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1378\/chest.72.1.105","article-title":"Fatal pneumonitis and septicemia after fiberoptic bronchoscopy","volume":"72","author":"Beyt, B.E.; King, D.K.; Glew, R.H.","year":"1977","unstructured":"Beyt BE, King DK, Glew RH. Fatal pneumonitis and septicemia after fiberoptic bronchoscopy. Chest 1977;72: 105-7.","journal-title":"Chest"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0140-6736(77)90138-6","article-title":"Transmission of Salmonella typhi by fiberoptic endoscopy","volume":"ii:","author":"Dean, A.G.","year":"1977","unstructured":"Dean AG. Transmission of Salmonella typhi by fiberoptic endoscopy. Lancet 1977;ii:134.","journal-title":"Lancet"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1001\/jama.1979.03290360029022","article-title":"Salmonella typhimurium transmission by fiberoptic upper gastrointestinal endoscopy","volume":"241","author":"Beecham, H.J.; Cohen, M.L.; Parkin, W.E.","year":"1979","unstructured":"Beecham HJ, Cohen ML, Parkin WE. Salmonella typhimurium transmission by fiberoptic upper gastrointestinal endoscopy. JAMA 1979;241:1013-5.","journal-title":"JAMA"},{"key":"ref_14","article-title":"Outbreak of Salmonella agona infection after upper intestinal fibreoptic endoscopy","author":"Schliessler, K.H.; Rozendaal, B.; Taal, C.; Meawissen, S.G.M.","year":"1980","unstructured":"Schliessler KH, Rozendaal B, Taal C, Meawissen SGM. Outbreak of Salmonella agona infection after upper intestinal fibreoptic endoscopy. Lancet 1980;ii:1246.","journal-title":"Lancet"},{"key":"ref_15","first-page":"275","article-title":"Disinfecting endoscopes: how not to transmit Mycobacterium tuberculosis by bronchoscopy","volume":"123","author":"Leers, W.D.","year":"1980","unstructured":"Leers WD. Disinfecting endoscopes: how not to transmit Mycobacterium tuberculosis by bronchoscopy. Can Med Assoc J 1980;123:275-83.","journal-title":"Can Med Assoc J"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1378\/chest.68.5.703","article-title":"Outbreak of Serratia marcescens associated with the flexible fibre bronchoscope","volume":"68","author":"Webb, S.F.; Vall-Spinosa, A.","year":"1974","unstructured":"Webb SF, Vall-Spinosa A. Outbreak of Serratia marcescens associated with the flexible fibre bronchoscope. Chest 1974;68:703-8.","journal-title":"Chest"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1016\/S0016-5085(19)32743-X","article-title":"Esophagoscopy as a source of Pseudomonas aeruginosa sepsis in patients with acute leukemia: the need for sterilization of endoscopes","volume":"67","author":"Greene, W.H.; Moody, M.; Hartley, R.; Effman, E.; Aisner, J.; Young, V.M.; Wiernik, P.H.","year":"1974","unstructured":"Greene WH, Moody M, Hartley R, Effman E, Aisner J, Young VM, Wiernik PH. Esophagoscopy as a source of Pseudomonas aeruginosa sepsis in patients with acute leukemia: the need for sterilization of endoscopes. Gastroenterology 1974;67:912-9.","journal-title":"Gastroenterology"},{"key":"ref_18","article-title":"Endoscopy and transmission of hepatitis B","author":"Morris, I.M.; Cattle, D.S.; Smits, B.J.","year":"1975","unstructured":"Morris IM, Cattle DS, Smits BJ. Endoscopy and transmission of hepatitis B. Lancet 1975;ii:1152.","journal-title":"Lancet"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S0016-5107(76)73735-0","article-title":"Can gastrointestinal endoscopy transmit hepatitis B to patients?","volume":"22","author":"McDonald, G.B.; Silverstein, F.E.","year":"1976","unstructured":"McDonald GB, Silverstein FE. Can gastrointestinal endoscopy transmit hepatitis B to patients? Gastrointest Endosc 1976;22:168-70.","journal-title":"Gastrointest Endosc"},{"key":"ref_20","first-page":"23","article-title":"Hepatitis B: absence of transmission by gastrointestinal endoscopy","volume":"i:","author":"McClelland, D.B.L.; Burrell, C.J.; Tonkin, R.W.; Heading, R.C.","year":"1978","unstructured":"McClelland DBL, Burrell CJ, Tonkin RW, Heading RC. Hepatitis B: absence of transmission by gastrointestinal endoscopy. Br MedJ 1978;i:23-4.","journal-title":"Br MedJ"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1001\/jama.1970.03170090025005","article-title":"Transmission of serum hepatitis","volume":"211","author":"Barker, L.F.; Shulman, N.R.; Murray, R.; Hirschman, R.J.; Ratner, F.; Diefenbach, W.C.L.; Geller, H.M.","year":"1970","unstructured":"Barker LF, Shulman NR, Murray R, Hirschman RJ, Ratner F, Diefenbach WCL, Geller HM. Transmission of serum hepatitis. JAMA 1970;211:1509-12.","journal-title":"JAMA"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1056\/NEJM197308302890908","article-title":"Transientbacteremia associated with sigmoidoscopy","volume":"289","author":"LeFrock, J.L.; Ellis, C.A.; Turchik, J.B.; etal","year":"1973","unstructured":"LeFrock JL, Ellis CA,Turchik JB,etal.Transientbacteremia associated with sigmoidoscopy. N EnglJ Med 1973;289: 467-9.","journal-title":"N EnglJ Med"},{"key":"ref_23","article-title":"Control ofhospital infection","author":"Lowbury, E.J.L.","year":"1975","unstructured":"Lowbury EJL, Ayliffe GAJ, Geddes AM, Williams JD, eds. Control ofhospital infection. London: Chapman and Hall 1975."},{"key":"ref_24","article-title":"Sterilisation and disinfection of cystoscopes. Notes on sterilisation No 1","author":"Gillespie, W.A.; Mitchell, J.P.","year":"1967","unstructured":"Gillespie WA, Mitchell JP. Sterilisation and disinfection of cystoscopes. Notes on sterilisation No 1. Association of Clinical Pathologists, 1967."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1378\/chest.66.6.723","article-title":"Experimental study for rapid sterilization of the flexible fiberoptic bronchoscope","volume":"66","author":"Kato, H.","year":"1974","unstructured":"Kato H. Experimental study for rapid sterilization of the flexible fiberoptic bronchoscope. Chest 1974;66:723-4.","journal-title":"Chest"},{"key":"ref_26","first-page":"1198","article-title":"A rapid method of disinfecting the bronchofiberscope","volume":"114","author":"Suratt, P.M.; Gwaltney, J.M.; Sande, M.A.","year":"1976","unstructured":"Suratt PM, Gwaltney JM, Sande MA. A rapid method of disinfecting the bronchofiberscope. Am Rev Respir Dis 1976; 114:1198-200.","journal-title":"Am Rev Respir Dis"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1136\/gut.19.10.916","article-title":"Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde","volume":"19","author":"Carr-Locke, D.L.; Clayton, P.","year":"1978","unstructured":"Carr-Locke DL, Clayton P. Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde. Gut 1978;19:916-22.","journal-title":"Gut"}],"container-title":["Journal of Clinical Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jcp.35.3.296","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,7]],"date-time":"2025-12-07T01:57:01Z","timestamp":1765072621000},"score":1,"resource":{"primary":{"URL":"https:\/\/jcp.bmj.com\/lookup\/doi\/10.1136\/jcp.35.3.296"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1982,3]]},"references-count":27,"journal-issue":{"issue":"3","published-online":{"date-parts":[[1982,3,1]]},"published-print":{"date-parts":[[1982,3]]}},"alternative-id":["10.1136\/jcp.35.3.296"],"URL":"https:\/\/doi.org\/10.1136\/jcp.35.3.296","relation":{},"ISSN":["0021-9746","1472-4146"],"issn-type":[{"type":"print","value":"0021-9746"},{"type":"electronic","value":"1472-4146"}],"subject":[],"published":{"date-parts":[[1982,3]]}}}