{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T23:35:50Z","timestamp":1794958550284,"version":"4.9.1"},"reference-count":19,"publisher":"BMJ","issue":"9","funder":[{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","award":["R01 NS076491"],"award-info":[{"award-number":["R01 NS076491"]}],"id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","award":["R43 NS110114"],"award-info":[{"award-number":["R43 NS110114"]}],"id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000065","name":"National Institute of Neurological Disorders and Stroke","doi-asserted-by":"publisher","award":["R01 NS076491"],"award-info":[{"award-number":["R01 NS076491"]}],"id":[{"id":"10.13039\/100000065","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000065","name":"National Institute of Neurological Disorders and Stroke","doi-asserted-by":"publisher","award":["R43 NS110114"],"award-info":[{"award-number":["R43 NS110114"]}],"id":[{"id":"10.13039\/100000065","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2022,8,26]]},"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Flow diverters have been widely used in clinical practice for more than a decade. However, most outcome data are limited to 1\u2009year timepoints. This study aims to offer meta-analysis data on long-term (&gt;1\u2009year) safety and effectiveness results for patients with aneurysms treated with flow diverters.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>PubMed, Web of Science, Embase, and SCOPUS were searched up to February 24, 2022 using the AutoLit platform. We included primary studies assessing the long-term outcomes for flow diverter devices to manage unruptured internal carotid artery aneurysms with a follow-up period of &gt;1\u2009year. The meta-analysis was carried out using Comprehensive Meta-Analysis software (CMA).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Eleven studies were included in the meta-analysis. The pooled occlusion rates after flow diversion treatment for unruptured intracranial brain aneurysms were 77%, 87.4%, 84.5%, 89.4%, 96% for 1\u2009year, 1\u20132 years, 2\u2009years, 3\u2009years, and 5\u2009years follow-up, respectively. The in-stent stenosis rate was 4.8% and the retreatment rate for the long-term follow-up period was 5%. No delayed rupture of the aneurysm was reported, and there was one case of delayed ischemic stroke. The sensitivity analysis of the prospective studies showed a complete occlusion rate of 83.5% and 85.2% for 1 and 3\u2009years of follow-up, respectively.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>Flow diverters are safe and effective in short- and long-term follow-up and rarely cause serious delayed side effects.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/jnis-2022-019240","type":"journal-article","created":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T14:00:14Z","timestamp":1663941614000},"page":"898-902","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":106,"title":["Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis"],"prefix":"10.1136","volume":"15","author":[{"given":"Mostafa A","family":"Shehata","sequence":"first","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0519-8936","authenticated-orcid":false,"given":"Mohamed K","family":"Ibrahim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5629-3023","authenticated-orcid":false,"given":"Sherief","family":"Ghozy","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cem","family":"Bilgin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2891-8633","authenticated-orcid":false,"given":"Mohamed Sobhi","family":"Jabal","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6786-9953","authenticated-orcid":false,"given":"Ramanathan","family":"Kadirvel","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David F","family":"Kallmes","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2022,9,23]]},"reference":[{"key":"2025092912262718000_15.9.898.1","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1093\/neuros\/nyz307","article-title":"Introduction: history and development of flow diverter technology and evolution","volume":"86","author":"K\u00fchn","year":"2020","journal-title":"Neurosurgery"},{"key":"2025092912262718000_15.9.898.2","doi-asserted-by":"publisher","DOI":"10.3171\/2017.3.FOCUS16450"},{"key":"2025092912262718000_15.9.898.3","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5591"},{"key":"2025092912262718000_15.9.898.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015091"},{"key":"2025092912262718000_15.9.898.5","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp-2011-302068"},{"key":"2025092912262718000_15.9.898.6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097"},{"key":"2025092912262718000_15.9.898.7","unstructured":"Long term outcomes of flow diversion common data elements, Autolit, nested knowledge 2021. in., 2022. Available: https:\/\/nested-knowledge.com\/"},{"key":"2025092912262718000_15.9.898.8","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.i4919"},{"key":"2025092912262718000_15.9.898.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018501"},{"key":"2025092912262718000_15.9.898.10","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2176\/nmc.oa.2021-0203","article-title":"Long-term follow-up results after flow diverter therapy using the Pipeline embolization device for large or giant unruptured internal carotid artery aneurysms: single-center retrospective analysis in the Japanese population","volume":"62","author":"Fujii","year":"2022","journal-title":"Neurol Med Chir"},{"key":"2025092912262718000_15.9.898.11","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-012-2581-4"},{"key":"2025092912262718000_15.9.898.12","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyw014"},{"key":"2025092912262718000_15.9.898.13","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1093\/ons\/opaa425","article-title":"Endovascular treatment of anterior circulation aneurysms with the p64 flow modulation device: mid- and long-term results in 617 aneurysms from a single center","volume":"20","author":"Aguilar P\u00e9rez","year":"2021","journal-title":"Oper Neurosurg"},{"key":"2025092912262718000_15.9.898.14","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4081"},{"key":"2025092912262718000_15.9.898.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2014.05.029"},{"key":"2025092912262718000_15.9.898.16","doi-asserted-by":"crossref","DOI":"10.3389\/fneur.2021.711863","article-title":"Endovascular treatment of posterior circulation saccular aneurysms with the p64 flow modulation device: mid-and long-term results in 54 aneurysms from a single center","volume":"12","author":"Hellstern","year":"2021","journal-title":"Front Neurol"},{"key":"2025092912262718000_15.9.898.17","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1093\/neuros\/nyab183","article-title":"Pipeline embolization devices for the treatment of intracranial aneurysms, single-center registry: long-term angiographic and clinical outcomes from 1000 aneurysms","volume":"89","author":"Lylyk","year":"2021","journal-title":"Neurosurgery"},{"key":"2025092912262718000_15.9.898.18","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-011-0948-x"},{"key":"2025092912262718000_15.9.898.19","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-013975"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2022-019240","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T19:26:36Z","timestamp":1759173996000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2022-019240"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,23]]},"references-count":19,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,8,17]]},"published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.1136\/jnis-2022-019240"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2022-019240","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,23]]}}}