{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T13:33:14Z","timestamp":1788787994403,"version":"build-2803163510"},"reference-count":19,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2023,3,16]]},"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Despite the growing sophistication of robot-assisted surgery, it is necessary to demonstrate that robots can reliably perform complex procedures on site and then remotely. Although a flow diverter stent is one of the most effective and widely used devices, its placement is sometimes challenging.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To evaluate the feasibility and safety of the CorPath GRX robotic platform for the embolization of cerebral and cervical aneurysms using flow diverter stents.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>We performed a single-center technical study of the first 10 flow diverter stent deployments with the CorPath GRX Robotic System (Corindus Inc, Waltham, Massachusetts, USA) for the treatment of cerebral aneurysms between April and October 2022.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Ten patients underwent robot-assisted embolization with flow diverter stents: there were nine intracranial aneurysms (paraclinoid n=6; posterior communicating artery aneurysm n=1; anterior communicating artery n=2) and one cervical aneurysm. Four procedures were performed with coils plus a flow diverter stent, one was performed with woven endobridge plus a flow diverter stent and four were performed with flow diverter stents alone. Of these procedures, two were performed with telescoping flow diverters.<\/jats:p>\n                  <jats:p>All flow diverter stents were deployed with robotic assistance, with only one partial conversion to a manual technique (caused by guidewire torquability limitations). No perioperative complications were observed.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>Robot-assisted flow diverter stent deployment using the CorPath GRX platform is feasible and appears to be safe. Larger, in-depth studies of the technique\u2019s safety and benefits are now warranted.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/jnis-2022-019968","type":"journal-article","created":{"date-parts":[[2023,3,31]],"date-time":"2023-03-31T13:23:14Z","timestamp":1680268994000},"page":"412-417","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":12,"title":["Robotically assisted deployment of flow diverter stents for the treatment of cerebral and cervical aneurysms"],"prefix":"10.1136","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1829-1200","authenticated-orcid":false,"given":"Cyril","family":"Chivot","sequence":"first","affiliation":[{"name":"Department of Radiology, Amiens University Hospital, Amiens, Hauts-de-France, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger","family":"Bouzerar","sequence":"additional","affiliation":[{"name":"Image Processing Department, Amiens University Hospital, Amiens, Hauts de France, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johann","family":"Peltier","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Amiens University Hospital, Amiens, Hauts de France, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Lefranc","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Amiens University Hospital, Amiens, Hauts de France, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thierry","family":"Yzet","sequence":"additional","affiliation":[{"name":"Department of Radiology, Amiens University Hospital, Amiens, Hauts-de-France, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2023,3,31]]},"reference":[{"key":"2025092913002335000_16.4.412.1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(05)67214-5"},{"key":"2025092913002335000_16.4.412.2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000073841.88563.E9"},{"key":"2025092913002335000_16.4.412.3","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.636019"},{"key":"2025092913002335000_16.4.412.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014840"},{"key":"2025092913002335000_16.4.412.5","doi-asserted-by":"crossref","first-page":"992","DOI":"10.3171\/2021.1.JNS203617","article-title":"Feasibility of robot-assisted neuroendovascular procedures","volume":"136","author":"Mendes Pereira","year":"2022","journal-title":"J Neurosurg"},{"key":"2025092913002335000_16.4.412.6","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015671.rep"},{"key":"2025092913002335000_16.4.412.7","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015763"},{"key":"2025092913002335000_16.4.412.8","first-page":"1","article-title":"Comparison of robotic-assisted carotid stenting and manual carotid stenting through the transradial approach","volume":"28","author":"Weinberg","year":"2020","journal-title":"J Neurosurg"},{"key":"2025092913002335000_16.4.412.9","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.neurad.2019.03.011","article-title":"WEB-assisted microwire navigation for the treatment of complex wide-neck intracranial aneurysms: technical note","volume":"47","author":"Cagnazzo","year":"2020","journal-title":"J Neuroradiol"},{"key":"2025092913002335000_16.4.412.10","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013596"},{"key":"2025092913002335000_16.4.412.11","doi-asserted-by":"crossref","first-page":"4504","DOI":"10.1007\/s00330-020-06777-x","article-title":"Radiation dose and fluoroscopy time of modern endovascular treatment techniques in patients with saccular unruptured intracranial aneurysms","volume":"30","author":"Forbrig","year":"2020","journal-title":"Eur Radiol"},{"key":"2025092913002335000_16.4.412.12","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)00678-9"},{"key":"2025092913002335000_16.4.412.13","first-page":"407","article-title":"Interventional committee of the Society of Cardiovascular Interventions. Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice","volume":"63","author":"Goldstein","year":"2004","journal-title":"Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv"},{"key":"2025092913002335000_16.4.412.14","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25927"},{"key":"2025092913002335000_16.4.412.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.12.045"},{"key":"2025092913002335000_16.4.412.16","doi-asserted-by":"crossref","first-page":"8178","DOI":"10.1007\/s00464-022-09256-0","article-title":"Surgeons\u2019 physical workload in open surgery versus robot-assisted surgery and nonsurgical tasks","volume":"36","author":"Fan","year":"2022","journal-title":"Surg Endosc"},{"key":"2025092913002335000_16.4.412.17","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0000000000002845"},{"key":"2025092913002335000_16.4.412.18","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.eclinm.2019.07.017","article-title":"Long distance tele-robotic-assisted percutaneous coronary intervention: a report of first-in-human experience","volume":"14","author":"Patel","year":"2019","journal-title":"EClinicalMedicine"},{"key":"2025092913002335000_16.4.412.19","doi-asserted-by":"crossref","DOI":"10.1136\/bmjno-2021-000141","article-title":"Remote robotic endovascular thrombectomy for acute ischaemic stroke","volume":"3","author":"Singer","year":"2021","journal-title":"BMJ Neurol Open"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2022-019968","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T20:00:27Z","timestamp":1759176027000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2022-019968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,31]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,3,14]]},"published-print":{"date-parts":[[2024,4]]}},"alternative-id":["10.1136\/jnis-2022-019968"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2022-019968","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,31]]}}}