{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T01:06:33Z","timestamp":1788570393987,"version":"build-2803163510"},"reference-count":34,"publisher":"BMJ","issue":"e2","license":[{"start":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T00:00:00Z","timestamp":1737590400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2024,12,18]]},"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Medium vessel occlusions (MeVOs) account for 25\u201340% of acute ischemic stroke. The Tenzing 5 (Route 92 Medical, San Mateo, California, USA) and FreeClimb 54 (Route 92 Medical, San Mateo, California, USA) catheter is a novel delivery\u2013aspiration catheter combination designed to facilitate aspiration thrombectomy (AT) of MeVOs. We report our clinical experience using the Tenzing assisted delivery of aspiration (TADA) technique with FreeClimb 54 for first-line AT of MeVO.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We retrospectively reviewed consecutive patients who underwent MeVO first-line AT using TADA with FreeClimb 54 at nine institutions in the USA and one in New Zealand.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>94 MeVOs (65 primary, 29 secondary) were treated in 92 patients: median age 71 (IQR 58\u201381) years; 49\/92 (53%) women. FreeClimb 54 was successfully delivered by Tenzing 5 to all 94\/94 MeVOs: 26 proximal M2; 44 distal M2; 5\u2009M3; 6\u2009A2; 4\u2009A3; and 8\u2009P2. Median target vessel diameter on DSA was 1.7 (IQR 1.4\u20131.8)\u2009mm. A leading microwire was used to advance Tenzing in 84% of cases. A stent retriever was used for additional thrombectomy passes in 6\/94 (6%) patients. For a primary MeVO, final modified expanded Thrombolysis in Cerebral Infarction (meTICI) 2B\u20133 reperfusion was achieved in 63\/65 (97%) patients, after a median of 1 (IQR 1\u20132) pass, with a first pass effect (FPE, meTICI 2C\u20133) in 43\/65 (66%). Secondary MeVO FPE (eTICI 2C\u20133) was achieved in 20\/29 (69%) patients. Tenzing 5\u2013FreeClimb 54 related complications occurred in 2\/94 (2%) patients: one perforation with asymptomatic subarachnoid hemorrhage and one embolus to new territory.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>MeVO first-line AT using the TADA technique with Tenzing 5 and FreeClimb 54 had a high FPE with a low complication rate.<\/jats:p><\/jats:sec>","DOI":"10.1136\/jnis-2024-022693","type":"journal-article","created":{"date-parts":[[2025,1,24]],"date-time":"2025-01-24T04:55:22Z","timestamp":1737694522000},"page":"e197-e205","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":13,"title":["Tenzing Assisted Delivery of Aspiration (TADA) technique for thrombectomy of medium vessel occlusions using the Freeclimb 54 catheter: multicenter experience"],"prefix":"10.1136","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5829-3163","authenticated-orcid":false,"given":"Fabio","family":"Settecase","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajit S","family":"Puri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shane SH","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajkamal S","family":"Khangura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald F","family":"Budzik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J","family":"Pema","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thymur","family":"Chaudury","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew J","family":"Page","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6685-4154","authenticated-orcid":false,"given":"Ben J","family":"McGuinness","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Colasurdo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel A","family":"Tonetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1152-8826","authenticated-orcid":false,"given":"Jonathan A","family":"Grossberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasmeet","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Luisa","family":"Kuhn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew D","family":"Alexander","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bahram","family":"Varjavand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan A","family":"Priest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JaeHyun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Blaise W","family":"Baxter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Warren T","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joey D","family":"English","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2353-9901","authenticated-orcid":false,"given":"James","family":"Caldwell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,1,23]]},"reference":[{"key":"2025060118400646000_17.e2.e197.1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(16)00163-X"},{"key":"2025060118400646000_17.e2.e197.2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(12)61299-9"},{"key":"2025060118400646000_17.e2.e197.3","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(12)61384-1"},{"key":"2025060118400646000_17.e2.e197.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011125"},{"key":"2025060118400646000_17.e2.e197.5","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2017.9644"},{"key":"2025060118400646000_17.e2.e197.6","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(19)30297-1"},{"key":"2025060118400646000_17.e2.e197.7","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.120.029949"},{"key":"2025060118400646000_17.e2.e197.8","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2022-019975"},{"key":"2025060118400646000_17.e2.e197.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2017-013702"},{"key":"2025060118400646000_17.e2.e197.10","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.120.028956"},{"key":"2025060118400646000_17.e2.e197.11","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016412"},{"key":"2025060118400646000_17.e2.e197.12","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2022-018806"},{"key":"2025060118400646000_17.e2.e197.13","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018318"},{"key":"2025060118400646000_17.e2.e197.14","doi-asserted-by":"crossref","unstructured":"Settecase F , Kim WT , Sivapatham T , et al . Improved catheter delivery for aspiration thrombectomy using Tenzing 7 ledge reducing catheter and FreeClimb 70. Interv Neuroradiol 2023;15910199231177754. doi:10.1177\/15910199231177754","DOI":"10.1177\/15910199231177754"},{"key":"2025060118400646000_17.e2.e197.15","doi-asserted-by":"crossref","first-page":"15910199231216765","DOI":"10.1177\/15910199231216765","article-title":"Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience","volume":"2023","author":"Tonetti","year":"2023","journal-title":"Interv Neuroradiol"},{"key":"2025060118400646000_17.e2.e197.16","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1177\/17474930241262642","article-title":"Endovascular treatment to improve outcomes for medium vessel occlusions: The ESCAPE-MeVO trial","volume":"19","author":"Ospel","year":"2024","journal-title":"Int J Stroke"},{"key":"2025060118400646000_17.e2.e197.17","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010665"},{"key":"2025060118400646000_17.e2.e197.18","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017321"},{"key":"2025060118400646000_17.e2.e197.19","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.115.010049"},{"key":"2025060118400646000_17.e2.e197.20","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39335.541782.AD"},{"key":"2025060118400646000_17.e2.e197.21","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017316"},{"key":"2025060118400646000_17.e2.e197.22","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A6987"},{"key":"2025060118400646000_17.e2.e197.23","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016459"},{"key":"2025060118400646000_17.e2.e197.24","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2021.13827"},{"key":"2025060118400646000_17.e2.e197.25","doi-asserted-by":"crossref","first-page":"e23","DOI":"10.1016\/j.wneu.2020.02.078","article-title":"Endovascular Contact Aspiration versus Stent Retriever for Revascularization in Patients with Acute Ischemic Stroke and Large Vessel Occlusion: A Cost-Minimization Analysis","volume":"139","author":"Malhotra","year":"2020","journal-title":"World Neurosurg"},{"key":"2025060118400646000_17.e2.e197.26","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2022-019344"},{"key":"2025060118400646000_17.e2.e197.27","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.wneu.2019.10.030","article-title":"Mechanical Thrombectomy of Distal Occlusions Using a Direct Aspiration First Pass Technique Compared with New Generation of Mini-0.017 Microcatheter Compatible\u2013Stent Retrievers: A Meta-Analysis","volume":"134","author":"Barchetti","year":"2020","journal-title":"World Neurosurg"},{"key":"2025060118400646000_17.e2.e197.28","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.wneu.2016.11.035","article-title":"Experience with A Direct Aspiration First Pass Technique (ADAPT) for Thrombectomy in Distal Cerebral Artery Occlusions Causing Acute Ischemic Stroke","volume":"99","author":"Vargas","year":"2017","journal-title":"World Neurosurg"},{"key":"2025060118400646000_17.e2.e197.29","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014990"},{"key":"2025060118400646000_17.e2.e197.30","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1007\/s00062-017-0594-8","article-title":"Single-Center Experience Using the 3MAX Reperfusion Catheter for the Treatment of Acute Ischemic Stroke with Distal Arterial Occlusions","volume":"28","author":"Premat","year":"2018","journal-title":"Clin Neuroradiol"},{"key":"2025060118400646000_17.e2.e197.31","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015508"},{"key":"2025060118400646000_17.e2.e197.32","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.120.032799"},{"key":"2025060118400646000_17.e2.e197.33","doi-asserted-by":"crossref","unstructured":"Kobeissi H , Ghozy S , Flood R , et al . Mechanical thrombectomy with Q catheter in stroke caused by primary and secondary distal and medium vessel occlusions. Interv Neuroradiol 2023;15910199231167915. doi:10.1177\/15910199231167915","DOI":"10.1177\/15910199231167915"},{"key":"2025060118400646000_17.e2.e197.34","doi-asserted-by":"publisher","DOI":"10.1177\/15910199211039926"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2024-022693","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T01:40:42Z","timestamp":1748828442000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2024-022693"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,23]]},"references-count":34,"journal-issue":{"issue":"e2","published-online":{"date-parts":[[2025,6,1]]},"published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1136\/jnis-2024-022693"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2024-022693","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,23]]}}}