{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T02:05:00Z","timestamp":1784081100470,"version":"3.55.0"},"reference-count":23,"publisher":"BMJ","issue":"4","funder":[{"name":"Health and Medical Research Fund, Hong Kong Food and Health Bureau","award":["10210366"],"award-info":[{"award-number":["10210366"]}]},{"name":"Shenzhen Science and Technology Program","award":["JCYJ20220531100611025"],"award-info":[{"award-number":["JCYJ20220531100611025"]}]},{"name":"National Natural Science Foundation of China \/ Research Grants Council Joint Research Scheme","award":["N_CUHK421\/16, 81661168015"],"award-info":[{"award-number":["N_CUHK421\/16, 81661168015"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2025,4,28]]},"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>In intracranial atherosclerotic stenosis (ICAS), low fractional flow (FF) may indicate hemodynamic significance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To investigate, using simulation models, whether invasive measurement could accurately reflect \u2018true\u2019 FF, when the catheter\/pressure wire might disturb focal flow during measurement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We recruited 5 patients with high-grade, symptomatic M1 middle cerebral artery stenosis in three-dimensional rotational angiography (3DRA). In each case, the stenotic severity was manually manipulated to 50%, 60%, 70%, and 80%. At each stenotic severity, we simulated four situations: no catheter\/pressure wire insertion (\u2018in vivo\u2019 status); only catheter inserted proximally to the ICAS; catheter inserted and pressure sensor placed at 1\u2009cm and 2\u2009cm distally to the ICAS lesion. The blood flow was simulated with computational fluid dynamics modeling, and FF measured as post-stenotic and pre-stenotic pressure ratio. We calculated relative differences of FFs simulated at other situations compared with in vivo status.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Compared with in vivo status, catheter insertion had no significant influence on simulated FFs. With pressure wire passing through the ICAS, simulated FFs slightly decreased (mostly &lt;10%) at 50% and 60% stenoses, which significantly decreased (up to 50% and 88%) at 70% and 80% stenoses. The effects of pressure wire on FFs were similar when the pressure sensor was placed at 1\u2009cm and 2\u2009cm distally to the ICAS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Invasive measurement of FF may overestimate the hemodynamic significance of ICAS with severe stenosis, as the pressure wire may further reduce the flow across the small residual lumen. The findings warrant verification in larger-scale studies, with information on collateral circulation and validation with other imaging modalities.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2025-023342","type":"journal-article","created":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T13:20:26Z","timestamp":1747747226000},"page":"1151-1156","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":3,"title":["Is invasive fractional flow measurement accurate in intracranial stenosis? A computational simulation study"],"prefix":"10.1136","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3624-6814","authenticated-orcid":false,"given":"Yu","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengzheng","family":"Yan","sequence":"additional","affiliation":[{"name":"Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziqi","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuying","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sze Ho","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bonaventure Yiu Ming","family":"Ip","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas Wai Hong","family":"Leung","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Liu","sequence":"additional","affiliation":[{"name":"Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7300-6647","authenticated-orcid":false,"given":"Xinyi","family":"Leng","sequence":"additional","affiliation":[{"name":"Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2025,5,20]]},"reference":[{"key":"2026031302250897000_18.4.1151.1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1747-4949.2006.00045.x"},{"key":"2026031302250897000_18.4.1151.2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1105335"},{"key":"2026031302250897000_18.4.1151.3","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2022.12000"},{"key":"2026031302250897000_18.4.1151.4","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.578229"},{"key":"2026031302250897000_18.4.1151.5","doi-asserted-by":"publisher","DOI":"10.1002\/ana.25456"},{"key":"2026031302250897000_18.4.1151.6","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1205361"},{"key":"2026031302250897000_18.4.1151.7","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199606273342604"},{"key":"2026031302250897000_18.4.1151.8","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0807611"},{"key":"2026031302250897000_18.4.1151.9","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehs436"},{"key":"2026031302250897000_18.4.1151.10","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1408758"},{"key":"2026031302250897000_18.4.1151.11","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.002491"},{"key":"2026031302250897000_18.4.1151.12","doi-asserted-by":"publisher","DOI":"10.1177\/1747493016685716"},{"key":"2026031302250897000_18.4.1151.13","first-page":"255","article-title":"Severity assessment of intracranial large artery stenosis by pressure gradient measurements: A feasibility study","volume":"88","author":"Han","year":"2016","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026031302250897000_18.4.1151.14","doi-asserted-by":"publisher","DOI":"10.1159\/000444333"},{"key":"2026031302250897000_18.4.1151.15","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1136\/jnnp-2020-325027","article-title":"Plaque morphology in acute symptomatic intracranial atherosclerotic disease","volume":"92","author":"Leung","year":"2020","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"2026031302250897000_18.4.1151.16","first-page":"643","article-title":"A standardized method for measuring intracranial arterial stenosis","volume":"21","author":"Samuels","year":"2000","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026031302250897000_18.4.1151.17","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.3392","article-title":"A parallel non-nested two-level domain decomposition method for simulating blood flows in cerebral artery of stroke patient","volume":"36","author":"Chen","year":"2020","journal-title":"Int J Numer Method Biomed Eng"},{"key":"2026031302250897000_18.4.1151.18","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1109\/TBME.2022.3225188","article-title":"Impact of Pressure Wire on Fractional Flow Reserve and Hemodynamics of the Coronary Arteries: A Computational and Clinical Study","volume":"70","author":"Yan","year":"2023","journal-title":"IEEE Trans Biomed Eng"},{"key":"2026031302250897000_18.4.1151.19","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.112.968511"},{"key":"2026031302250897000_18.4.1151.20","doi-asserted-by":"publisher","DOI":"10.1111\/j.1552-6569.2012.00711.x"},{"key":"2026031302250897000_18.4.1151.21","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-13-0161"},{"key":"2026031302250897000_18.4.1151.22","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2023-020144"},{"key":"2026031302250897000_18.4.1151.23","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-007-0252-y"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2025-023342","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T18:47:04Z","timestamp":1773427624000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2025-023342"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,20]]},"references-count":23,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,3,13]]},"published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1136\/jnis-2025-023342"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2025-023342","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,20]]}}}