{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T04:43:53Z","timestamp":1788237833485,"version":"build-2803163510"},"reference-count":47,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2026,1,16]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The SpineJack system is a minimally invasive device designed to restore vertebral height and stability in vertebral compression fractures (VCFs). This systematic review and meta-analysis evaluates its clinical efficacy, safety, and potential advantages over conventional treatments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. PubMed, Embase, and Scopus were searched on July 20, 2024, for original clinical studies involving adult patients with VCFs treated using the SpineJack system. Studies reporting quantitative outcomes such as pain (Visual Analog Scale, VAS), disability (Oswestry Disability Index, ODI), and vertebral body height (VBH) restoration were included. Data were pooled using random-effects models, and publication bias was assessed through funnel plots and regression analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>18 studies comprising 1482 patients (930 treated with SpineJack) met the inclusion criteria. Fracture etiologies included osteoporotic, traumatic, and pathologic. Meta-analysis demonstrated significant reductions in pain (VAS standardized mean difference (SMD) 2.26, 95%\u2009CI 1.68 to 2.84, P&lt;0.001) and disability (ODI SMD 3.64, 95%\u2009CI 2.91 to 4.38, P&lt;0.001). Restoration of anterior VBH (SMD 1.45, 95%\u2009CI 1.12 to 1.78, P&lt;0.001, I\u00b2=0%), and middle VBH (SMD 3.93, 95%\u2009CI 1.51 to 6.34, P=0.001) were both significant. Reported complications were infrequent and primarily minor.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The SpineJack system provides a safe and effective minimally invasive option for VCF management, yielding considerable improvements in pain relief, functional recovery, and vertebral height restoration. Additional high-quality studies are warranted to further define its comparative advantages and long-term outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2025-024565","type":"journal-article","created":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T18:20:26Z","timestamp":1770142826000},"page":"jnis-2025-024565","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Efficacy and safety of SpineJack for treating vertebral compression fractures: systematic review and meta-analysis"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-4434-1127","authenticated-orcid":false,"given":"Jack E","family":"Stanfield","sequence":"first","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin B","family":"Arbuckle","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary A","family":"Smith","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John F","family":"Burke","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Li","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Burhan","family":"Janjua","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hakeem J","family":"Shakir","sequence":"additional","affiliation":[{"name":"Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,2,3]]},"reference":[{"key":"2026020310202086000_jnis-2025-024565v1.1","first-page":"44","article-title":"Diagnosis and Management of Vertebral Compression Fractures","volume":"94","author":"McCarthy","year":"2016","journal-title":"Am Fam Physician"},{"key":"2026020310202086000_jnis-2025-024565v1.2","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2024.32041","article-title":"Conservative Treatments in the Management of Acute Painful Vertebral Compression Fractures: A Systematic Review and Network Meta-Analysis","volume":"7","author":"Alimy","year":"2024","journal-title":"JAMA Netw Open"},{"key":"2026020310202086000_jnis-2025-024565v1.3","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000004491","article-title":"Vertebroplasty and balloon kyphoplasty versus conservative treatment for osteoporotic vertebral compression fractures: a meta-analysis","volume":"95","author":"Yuan","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"2026020310202086000_jnis-2025-024565v1.4","article-title":"Re-expansion of Osteoporotic Compression Fractures Using Bilateral SpineJack Implants: Early Clinical Experience and Biomechanical Considerations","volume":"11","author":"Jacobson","year":"2019","journal-title":"Cureus"},{"key":"2026020310202086000_jnis-2025-024565v1.5","unstructured":"SpineJack system. Stryker. Available: https:\/\/www.stryker.com\/us\/en\/interventional-spine\/products\/spinejack-system.html [Accessed 17 Oct 2025]."},{"key":"2026020310202086000_jnis-2025-024565v1.6","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"2026020310202086000_jnis-2025-024565v1.7","unstructured":"ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. The BMJ. Available: https:\/\/www.bmj.com\/content\/355\/bmj.i4919 [Accessed 16 Jun 2025]."},{"key":"2026020310202086000_jnis-2025-024565v1.8","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.l4898","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"key":"2026020310202086000_jnis-2025-024565v1.9","unstructured":"Jamovi - open statistical software for the desktop and cloud. Available: https:\/\/www.jamovi.org\/ [Accessed 17 Oct 2024]."},{"key":"2026020310202086000_jnis-2025-024565v1.10","doi-asserted-by":"publisher","DOI":"10.18637\/jss.v036.i11"},{"key":"2026020310202086000_jnis-2025-024565v1.11","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/173872","article-title":"Clinical Performance and Safety of 108 SpineJack Implantations: 1-Year Results of a Prospective Multicentre Single-Arm Registry Study","volume":"2015","author":"Noriega","year":"2015","journal-title":"Biomed Res Int"},{"key":"2026020310202086000_jnis-2025-024565v1.12","doi-asserted-by":"publisher","DOI":"10.15537\/smj.2015.1.9463"},{"key":"2026020310202086000_jnis-2025-024565v1.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2015.08.009"},{"key":"2026020310202086000_jnis-2025-024565v1.14","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/927813","article-title":"Clinical outcome after the use of a new craniocaudal expandable implant for vertebral compression fracture treatment: one year results from a prospective multicentric study","volume":"2015","author":"Noriega","year":"2015","journal-title":"Biomed Res Int"},{"key":"2026020310202086000_jnis-2025-024565v1.15","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5544-6"},{"key":"2026020310202086000_jnis-2025-024565v1.16","doi-asserted-by":"crossref","first-page":"624","DOI":"10.21037\/jss.2018.07.08","article-title":"A Colombian experience involving SpineJack\u00ae, a consecutive series of patients experiencing spinal fractures, percutaneous approach and anatomical restoration 2016-2017","volume":"4","author":"Mu\u00f1oz Montoya","year":"2018","journal-title":"J Spine Surg"},{"key":"2026020310202086000_jnis-2025-024565v1.17","doi-asserted-by":"publisher","DOI":"10.1007\/s00198-018-4773-5"},{"key":"2026020310202086000_jnis-2025-024565v1.18","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-019-04391-1"},{"key":"2026020310202086000_jnis-2025-024565v1.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2019.07.009"},{"key":"2026020310202086000_jnis-2025-024565v1.20","doi-asserted-by":"crossref","first-page":"5641","DOI":"10.1007\/s00330-020-06889-4","article-title":"Safety of vertebral augmentation with cranio-caudal expansion implants in vertebral compression fractures with posterior wall protrusion","volume":"30","author":"Meyblum","year":"2020","journal-title":"Eur Radiol"},{"key":"2026020310202086000_jnis-2025-024565v1.21","doi-asserted-by":"crossref","first-page":"101","DOI":"10.4103\/fjs.fjs_5_20","article-title":"Comparison of an intravertebral reduction device and percutaneous vertebroplasty for anatomical reduction with single-level vertebral compression fractures","volume":"53","author":"Huang","year":"2020","journal-title":"Formosan Journal of Surgery"},{"key":"2026020310202086000_jnis-2025-024565v1.22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2021.04.031"},{"key":"2026020310202086000_jnis-2025-024565v1.23","doi-asserted-by":"crossref","first-page":"242","DOI":"10.21037\/jss-21-118","article-title":"Treatment of thoracolumbar burst fractures: SpineJack vs. posterior arthrodesis-comparison of clinical and radiological outcomes","volume":"8","author":"Giordan","year":"2022","journal-title":"J Spine Surg"},{"key":"2026020310202086000_jnis-2025-024565v1.24","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017682"},{"key":"2026020310202086000_jnis-2025-024565v1.25","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A8031"},{"key":"2026020310202086000_jnis-2025-024565v1.26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5604\/01.3001.0053.4025","article-title":"Outcomes of Treatment of Spinal Fractures with the SpineJack System","volume":"25","author":"Sowa","year":"2023","journal-title":"Ortop Traumatol Rehabil"},{"key":"2026020310202086000_jnis-2025-024565v1.27","first-page":"790","article-title":"A prospective multicenter randomized study comparing the SpineJack system and nonsurgical management with a brace in acute traumatic vertebral fractures: the SPICO study","volume":"40","author":"Ould-Slimane","year":"2024","journal-title":"J Neurosurg"},{"key":"2026020310202086000_jnis-2025-024565v1.28","first-page":"21925682251347225","article-title":"The Use of Percutaneous Stent-Kyphoplasty (SpineJack\u00ae) in Osteoporotic and Non-Osteoporotic Vertebral Fractures: A Retrospective Analysis of 310 Implants From a Level-1 Trauma Center in Switzerland","volume":"16","author":"Karner","year":"2025","journal-title":"Global Spine J"},{"key":"2026020310202086000_jnis-2025-024565v1.29","doi-asserted-by":"publisher","DOI":"10.4088\/JCP.20f13681"},{"key":"2026020310202086000_jnis-2025-024565v1.30","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.1007\/s00198-016-3494-x","article-title":"Safety and clinical performance of kyphoplasty and SpineJack\u00ae procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study","volume":"27","author":"Noriega","year":"2016","journal-title":"Osteoporos Int"},{"key":"2026020310202086000_jnis-2025-024565v1.31","doi-asserted-by":"publisher","DOI":"10.1007\/s00198-004-1646-x"},{"key":"2026020310202086000_jnis-2025-024565v1.32","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.clinbiomech.2015.04.015","article-title":"Minimum cement volume required in vertebral body augmentation\u2014A biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture","volume":"30","author":"Rotter","year":"2015","journal-title":"Clin Biomech (Bristol)"},{"key":"2026020310202086000_jnis-2025-024565v1.33","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1097\/BRS.0b013e3181a3c742","article-title":"Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications","volume":"34","author":"Lee","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"2026020310202086000_jnis-2025-024565v1.34","doi-asserted-by":"crossref","first-page":"111184","DOI":"10.1016\/j.jocn.2025.111184","article-title":"Rate and fate of incidental durotomies in spine surgery","volume":"136","author":"Shah","year":"2025","journal-title":"J Clin Neurosci"},{"key":"2026020310202086000_jnis-2025-024565v1.35","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.wneu.2017.05.142","article-title":"Requirements for a Stable Long-Term Result in Surgical Reduction of Vertebral Fragility Fractures","volume":"105","author":"Crespo-Sanju\u00e1n","year":"2017","journal-title":"World Neurosurg"},{"key":"2026020310202086000_jnis-2025-024565v1.36","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2013.10.001"},{"key":"2026020310202086000_jnis-2025-024565v1.37","first-page":"3877","article-title":"Factors affecting cement leakage in percutaneous vertebroplasty: a retrospective cohort study of 309 patients","volume":"27","author":"Hou","year":"2023","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"2026020310202086000_jnis-2025-024565v1.38","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/BRS.0000000000003773","article-title":"Risk Factors for Cement Leakage in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures: An Analysis of 1456 Vertebrae Augmented by Low-Viscosity Bone Cement","volume":"46","author":"Tang","year":"2021","journal-title":"Spine (Phila Pa 1976)"},{"key":"2026020310202086000_jnis-2025-024565v1.39","doi-asserted-by":"crossref","first-page":"2680","DOI":"10.1007\/s00586-020-06636-9","article-title":"Comparison between vertebroplasty with high or low viscosity cement augmentation or kyphoplasty in cement leakage rate for patients with vertebral compression fracture: a systematic review and network meta-analysis","volume":"30","author":"Chen","year":"2021","journal-title":"Eur Spine J"},{"key":"2026020310202086000_jnis-2025-024565v1.40","doi-asserted-by":"crossref","first-page":"2349","DOI":"10.1007\/s10143-022-01755-x","article-title":"Subsequent fractures after vertebroplasty in osteoporotic vertebral fractures: a meta-analysis","volume":"45","author":"Ding","year":"2022","journal-title":"Neurosurg Rev"},{"key":"2026020310202086000_jnis-2025-024565v1.41","doi-asserted-by":"crossref","first-page":"7185","DOI":"10.1007\/s00330-024-10807-3","article-title":"Risk of adjacent level fracture after percutaneous vertebroplasty and kyphoplasty vs natural history for the management of osteoporotic vertebral compression fractures: a network meta-analysis of randomized controlled trials","volume":"34","author":"Essibayi","year":"2024","journal-title":"Eur Radiol"},{"key":"2026020310202086000_jnis-2025-024565v1.42","doi-asserted-by":"crossref","first-page":"17999","DOI":"10.1038\/s41598-024-68835-4","article-title":"Incidence and risk factors of adjacent vertebral fracture after percutaneous vertebroplasty or kyphoplasty in postmenopausal women: a retrospective study","volume":"14","author":"Cheng","year":"2024","journal-title":"Sci Rep"},{"key":"2026020310202086000_jnis-2025-024565v1.43","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.wneu.2020.08.216","article-title":"Comparison Between 7 Osteoporotic Vertebral Compression Fractures Treatments: Systematic Review and Network Meta-analysis","volume":"145","author":"Chang","year":"2021","journal-title":"World Neurosurg"},{"key":"2026020310202086000_jnis-2025-024565v1.44","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1007\/s00586-025-08707-1","article-title":"Re-evaluating vertebral height restoration assessment in osteoporotic compression fractures: a systematic review and meta-analysis","volume":"34","author":"Marino","year":"2025","journal-title":"Eur Spine J"},{"key":"2026020310202086000_jnis-2025-024565v1.45","doi-asserted-by":"crossref","first-page":"47","DOI":"10.4103\/0974-8237.116537","article-title":"New perspective for third generation percutaneous vertebral augmentation procedures: preliminary results at 12 months","volume":"3","author":"Vanni","year":"2012","journal-title":"J Craniovertebr Junction Spine"},{"key":"2026020310202086000_jnis-2025-024565v1.46","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2010.05.018"},{"key":"2026020310202086000_jnis-2025-024565v1.47","doi-asserted-by":"publisher","DOI":"10.1002\/jrsm.1411"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2025-024565","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T18:20:31Z","timestamp":1770142831000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2025-024565"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,3]]},"references-count":47,"alternative-id":["10.1136\/jnis-2025-024565"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2025-024565","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,3]]}}}